Powers
Armstrong International


Displaying: 1 - 24 of 1,982 Matching Items
1,982 Items
View:
Active Filters :
Part #:706624

Inverted Bucket Steam TrapsEnergy efficient because it's so reliable The inverted bucket is the most reliable steam trap operating principle known. The heart of its simple design is a unique leverage system that multiplies the force provided by the bucket to open the valve against pressure. Since the bucket is open at the bottom, it resists damage from water hammer, and wear points are heavily reinforced for long life. The inverted bucket has only two moving parts-the valve lever assembly and the bucket. That means no fixed points, no complicated linkage. Nothing to stick, bind or clog. Conserves energy even in the presence of wear Armstrong inverted bucket steam traps open and close based on the difference in density between condensate and steam-the inverted bucket principle. They open and close gently, minimizing wear. This simple fact means that inverted buckets are subject to less wear than some other types of traps. In fact, as an Armstrong inverted bucket trap wears, its tight seal actually improves. The valve and seat of the Armstrong trap provide essentially line contact-resulting in a tight seal because the entire closing force is concentrated on one narrow seating ring. An Armstrong inverted bucket steam trap continues to operate efficiently with use. Gradual wear slightly increases the diameter of the seat and alters the shape and diameter of the valve. But, as this occurs, a tight seal is still preserved-the ball merely seats itself more deeply. Corrosion-resistant parts The stainless steel valve and seat of the Armstrong inverted bucket steam trap are individually ground and lapped together in matched sets. All other working parts are wear- and corrosion-resistant stainless steel. Venting of air and CO2 The Armstrong inverted bucket provides continuous automatic air and CO2 venting with no cooling lag or threat of air binding. Operation against back pressure The Armstrong inverted bucket has excellent performance against back pressure. It has no adverse effect on inverted bucket operation other than to reduce its capacity by the low differential. The bucket simply requires less force to pull the valve open and cycle the trap. Freedom from dirt problems Armstrong designed its inverted bucket to be virtually free of dirt problems. The valve and seat are at the top of the trap, far away from the larger particles of dirt, which fall to the bottom. Here, the up-and-down action of the bucket pulverizes them. Since the valve of an inverted bucket is either fully closed or open, dirt particles pass freely. And the swift flow of condensate from under the bucket's edge creates a unique self-scrubbing action that sweeps dirt out of the trap.
$494.00 MSRP $ 386.91
Part #:706681

Steam Trap ConnectorsBesides 2000 Series stainless steel inverted bucket traps, the standard 360&deg connector or IS-2 connector with integral strainer can also be used on many Armstrong thermostatic, disc, bimetallic, and float and thermostatic traps. Any manufacturer&rsquos two-bolt steam traps can use Armstrong connectors. IS-2 Stainless Steel Connector with Integral Strainer &bull A full line stainless steel strainer in the connector eliminates leak points and reduces installation time &bull A strainer that is not discarded when the trap is replaced &bull Easy strainer screen replacement &bull Optional blowdown valve &bull Accommodates Armstrong&rsquos inverted bucket, disc, thermostatic, thermostatic wafer, bimetallic, and float and thermostatic traps. Any manufacturer&rsquos 2-bolt steam trap can also be applied to Armstrong&rsquos S-2 connector. Standard 360&deg Stainless Steel Connector &bull A compact, lightweight assembly &bull Standardization, reducing inventory &bull A compact design, simplifying piping &bull Accommodates Armstrong&rsquos inverted bucket, disc, thermostatic, thermostatic wafer and bimetallic steam traps. Any manufacturer&rsquos 2-bolt steam trap can also be applied to Armstrong&rsquos standard connector.
$442.00 MSRP $ 346.19
Part #:708464

Steam Trap ConnectorsBesides 2000 Series stainless steel inverted bucket traps, the standard 360&deg connector or IS-2 connector with integral strainer can also be used on many Armstrong thermostatic, disc, bimetallic, and float and thermostatic traps. Any manufacturer&rsquos two-bolt steam traps can use Armstrong connectors. IS-2 Stainless Steel Connector with Integral Strainer &bull A full line stainless steel strainer in the connector eliminates leak points and reduces installation time &bull A strainer that is not discarded when the trap is replaced &bull Easy strainer screen replacement &bull Optional blowdown valve &bull Accommodates Armstrong&rsquos inverted bucket, disc, thermostatic, thermostatic wafer, bimetallic, and float and thermostatic traps. Any manufacturer&rsquos 2-bolt steam trap can also be applied to Armstrong&rsquos S-2 connector. Standard 360&deg Stainless Steel Connector &bull A compact, lightweight assembly &bull Standardization, reducing inventory &bull A compact design, simplifying piping &bull Accommodates Armstrong&rsquos inverted bucket, disc, thermostatic, thermostatic wafer and bimetallic steam traps. Any manufacturer&rsquos 2-bolt steam trap can also be applied to Armstrong&rsquos standard connector.
$347.00 MSRP $ 271.78
Part #:519037

Country of Origin VN:
$0.34 MSRP $ 0.28
Part #:713360

Y-Type Cast Iron Strainers 250 lb Screwed 1/2"-3" Class 125 Flanged 2"-6" Class 250 Flanged 2"-6" Screen chambers won't leak or crush Both ends of the chambers are precisely machined. This means perfectly round and smooth seating surfaces, as well as a fixed chamber length. Since the screen seats snugly on the machined surface, no particle bigger than the screen opening can escape around the end of the screen. Screwed retainers easy in, easy out Straight threads mean it takes less torque to achieve a tight seal with proper gasket compression. Less torque is also required to remove the retainer. For you, that means less danger of "freezing in" than with hard-to-break tapered pipe threads. Off-center blowdown connections for better dirt removal Off-center drains on 2-1/2" and 3" strainers allow you to remove liquid and dirt nearly completely when blowing down the strainer. Also, less liquid will spill when the screen retainer is removed. Many screen choices Many screen materials, meshes and perforations are available.
$28.00 MSRP $ 21.52
Part #:713363

Y-Type Cast Iron Strainers 250 lb Screwed 1/2"-3" Class 125 Flanged 2"-6" Class 250 Flanged 2"-6" Screen chambers won't leak or crush Both ends of the chambers are precisely machined. This means perfectly round and smooth seating surfaces, as well as a fixed chamber length. Since the screen seats snugly on the machined surface, no particle bigger than the screen opening can escape around the end of the screen. Screwed retainers easy in, easy out Straight threads mean it takes less torque to achieve a tight seal with proper gasket compression. Less torque is also required to remove the retainer. For you, that means less danger of "freezing in" than with hard-to-break tapered pipe threads. Off-center blowdown connections for better dirt removal Off-center drains on 2-1/2" and 3" strainers allow you to remove liquid and dirt nearly completely when blowing down the strainer. Also, less liquid will spill when the screen retainer is removed. Many screen choices Many screen materials, meshes and perforations are available.
$74.00 MSRP $ 56.79
Part #:713364

Y-Type Cast Iron Strainers 250 lb Screwed 1/2"-3" Class 125 Flanged 2"-6" Class 250 Flanged 2"-6" Screen chambers won't leak or crush Both ends of the chambers are precisely machined. This means perfectly round and smooth seating surfaces, as well as a fixed chamber length. Since the screen seats snugly on the machined surface, no particle bigger than the screen opening can escape around the end of the screen. Screwed retainers easy in, easy out Straight threads mean it takes less torque to achieve a tight seal with proper gasket compression. Less torque is also required to remove the retainer. For you, that means less danger of "freezing in" than with hard-to-break tapered pipe threads. Off-center blowdown connections for better dirt removal Off-center drains on 2-1/2" and 3" strainers allow you to remove liquid and dirt nearly completely when blowing down the strainer. Also, less liquid will spill when the screen retainer is removed. Many screen choices Many screen materials, meshes and perforations are available.
$70.00 MSRP $ 53.80
Part #:713366

Y-Type Cast Iron Strainers 250 lb Screwed 1/2"-3" Class 125 Flanged 2"-6" Class 250 Flanged 2"-6" Screen chambers won't leak or crush Both ends of the chambers are precisely machined. This means perfectly round and smooth seating surfaces, as well as a fixed chamber length. Since the screen seats snugly on the machined surface, no particle bigger than the screen opening can escape around the end of the screen. Screwed retainers easy in, easy out Straight threads mean it takes less torque to achieve a tight seal with proper gasket compression. Less torque is also required to remove the retainer. For you, that means less danger of "freezing in" than with hard-to-break tapered pipe threads. Off-center blowdown connections for better dirt removal Off-center drains on 2-1/2" and 3" strainers allow you to remove liquid and dirt nearly completely when blowing down the strainer. Also, less liquid will spill when the screen retainer is removed. Many screen choices Many screen materials, meshes and perforations are available.
$116.00 MSRP $ 87.46
Part #:713381

Float and Thermostatic (F&ampT) Steam TrapsThe More Your Steam Pressure Varies, The More You Need Armstrong F&ampT TrapsWhen steam pressure may vary from maximum steam supply pressure to vacuum, Armstrong F&ampTs are your most energy-efficient choice. Our line of F&ampTs brings Armstrong performance, dependability and long life to trapping services requiring continuous drainage with high air venting capacity. Thanks to separate orifices for condensate and air, they provide continuous condensate drainage and air venting-even under conditions of zero pressure. All the benefits detailed here have been designed into Armstrong F&ampTs through long experience in the manufacture of pressure float-type traps. They assure you of optimum operating efficiency for long periods with minimum trouble. How they work Float and thermostatic traps are mechanical units that operate on both density and temperature principles. The float valve operates on the density principle. A level connects the ball float to the valve and seat. Once condensate reaches a certain level in the trap, the float rises, opening the orifice and draining condensate. A water seal formed by the condensate prevents live steam loss. Since the discharge valve is under water, it is not capable of venting air and non-condensables. When the accumulation of air and con-condensable gases causes a significant temperature drop, a thermostatic air vent in the top of the trap discharges them. The thermostatic vent opens at a temperature a few degrees below saturation, so it's able to handle a large volume of air-through an entirely separate orifice-but at a slightly reduced temperature. Built as tough as the jobs they do Armstrong float and thermostatic traps are unique in their super heavy duty construction. Armstrong uses high quality ASTM A48 Class 30 cast iron or ASTM A216 WCB cast steel-normally found in pressure vessels rated to 250 psi (17 bar) or 465 psi (32 bar). Internal mechanisms are made from stainless steel and are heavily reinforced. No brass cotter pins here. Valves and seats are stainless steel, hardened, ground and lapped to withstand the erosive forces of flashing condensate. Why go to all this trouble for traps normally recommended for low-pressure, modulating service? The operative word here is modulating. Modulating pressures mean widely varying loads, thermal cycling and high air and non-condensable gas loads. In other words tough service. Inferior, lightweight construction in this kind of service is a mistake waiting to happen. Trap failures on modulating pressure may lead to water hammer, corrosion and even damage to heat exchangers. Armstrong's published capacities are based on actual measurements of traps handling hot, flashing condensate. Competitive F&ampTs may utilize theoretical calculated capacities. Armstrong uses its own steam lab to give you actual capacity-especially important on high-capacity traps such as those in our ultra-capacity line. Not only does Armstrong offer super heavy duty construction for long life and reliability, but we also supply the data to back up performance. Here's a simple, easy-to-remember summary The more your pressure varies, the more you need Armstrong F&ampTs.
$310.00 MSRP $ 242.81
Part #:701257

The most reliable steam trap known&mdashthe inverted bucket&mdashprovides efficientcondensate drainage of virtually all types of steam-using equipment. Putthe inverted bucket to work in a tough cast iron package, and you have thebest of both worlds. Because they operate efficiently for longer periods oftime, Armstrong cast iron inverted buckets add solid energy savings to lowerreplacement/labor costs. All Armstrong cast iron inverted bucket steam trapsare repairable for even bigger maintenance savings. A unique leverage system multiplies the force provided by the bucket to openthe valve against system pressure. The mechanism is free-floating, and hasno fixed pivots to create wear or friction. Because the mechanism is located at the top of the trap, no dirt can collecton the orifice. Small particles of dirt are held in suspension until dischargedby the full differential purging action when the bucket sinks, pulling the valveoff the seat. The discharge orifice is surrounded by a water seal, preventing live steamloss. Automatic air venting is provided by a small vent hole in the bucket, whichprovides continuous automatic air and CO2 venting at steam temperature.Inverted bucket traps drain continuously, although discharging intermittently,allowing no condensate backup. They are also resistant to water hammer.
$295.00 MSRP $ 226.74
Part #:701262

The most reliable steam trap known&mdashthe inverted bucket&mdashprovides efficientcondensate drainage of virtually all types of steam-using equipment. Putthe inverted bucket to work in a tough cast iron package, and you have thebest of both worlds. Because they operate efficiently for longer periods oftime, Armstrong cast iron inverted buckets add solid energy savings to lowerreplacement/labor costs. All Armstrong cast iron inverted bucket steam trapsare repairable for even bigger maintenance savings. A unique leverage system multiplies the force provided by the bucket to openthe valve against system pressure. The mechanism is free-floating, and hasno fixed pivots to create wear or friction. Because the mechanism is located at the top of the trap, no dirt can collecton the orifice. Small particles of dirt are held in suspension until dischargedby the full differential purging action when the bucket sinks, pulling the valveoff the seat. The discharge orifice is surrounded by a water seal, preventing live steamloss. Automatic air venting is provided by a small vent hole in the bucket, whichprovides continuous automatic air and CO2 venting at steam temperature.Inverted bucket traps drain continuously, although discharging intermittently,allowing no condensate backup. They are also resistant to water hammer.
$295.00 MSRP $ 226.74
Part #:706405

Y-Type Cast Iron Strainers 250 lb Screwed 1/2"-3" Class 125 Flanged 2"-6" Class 250 Flanged 2"-6" Screen chambers won't leak or crush Both ends of the chambers are precisely machined. This means perfectly round and smooth seating surfaces, as well as a fixed chamber length. Since the screen seats snugly on the machined surface, no particle bigger than the screen opening can escape around the end of the screen. Screwed retainers easy in, easy out Straight threads mean it takes less torque to achieve a tight seal with proper gasket compression. Less torque is also required to remove the retainer. For you, that means less danger of "freezing in" than with hard-to-break tapered pipe threads. Off-center blowdown connections for better dirt removal Off-center drains on 2-1/2" and 3" strainers allow you to remove liquid and dirt nearly completely when blowing down the strainer. Also, less liquid will spill when the screen retainer is removed. Many screen choices Many screen materials, meshes and perforations are available.
$693.00 MSRP $ 532.64
Part #:710287

The most reliable steam trap known&mdashthe inverted bucket&mdashprovides efficientcondensate drainage of virtually all types of steam-using equipment. Putthe inverted bucket to work in a tough cast iron package, and you have thebest of both worlds. Because they operate efficiently for longer periods oftime, Armstrong cast iron inverted buckets add solid energy savings to lowerreplacement/labor costs. All Armstrong cast iron inverted bucket steam trapsare repairable for even bigger maintenance savings. A unique leverage system multiplies the force provided by the bucket to openthe valve against system pressure. The mechanism is free-floating, and hasno fixed pivots to create wear or friction. Because the mechanism is located at the top of the trap, no dirt can collecton the orifice. Small particles of dirt are held in suspension until dischargedby the full differential purging action when the bucket sinks, pulling the valveoff the seat. The discharge orifice is surrounded by a water seal, preventing live steamloss. Automatic air venting is provided by a small vent hole in the bucket, whichprovides continuous automatic air and CO2 venting at steam temperature.Inverted bucket traps drain continuously, although discharging intermittently,allowing no condensate backup. They are also resistant to water hammer.
$295.00 MSRP $ 226.74
Part #:713370

Y-Type Cast Iron Strainers 250 lb Screwed 1/2"-3" Class 125 Flanged 2"-6" Class 250 Flanged 2"-6" Screen chambers won't leak or crush Both ends of the chambers are precisely machined. This means perfectly round and smooth seating surfaces, as well as a fixed chamber length. Since the screen seats snugly on the machined surface, no particle bigger than the screen opening can escape around the end of the screen. Screwed retainers easy in, easy out Straight threads mean it takes less torque to achieve a tight seal with proper gasket compression. Less torque is also required to remove the retainer. For you, that means less danger of "freezing in" than with hard-to-break tapered pipe threads. Off-center blowdown connections for better dirt removal Off-center drains on 2-1/2" and 3" strainers allow you to remove liquid and dirt nearly completely when blowing down the strainer. Also, less liquid will spill when the screen retainer is removed. Many screen choices Many screen materials, meshes and perforations are available
$794.00 MSRP $ 598.65
Part #:706642

Steam Trap ConnectorsBesides 2000 Series stainless steel inverted bucket traps, the standard 360&deg connector or IS-2 connector with integral strainer can also be used on many Armstrong thermostatic, disc, bimetallic, and float and thermostatic traps. Any manufacturer&rsquos two-bolt steam traps can use Armstrong connectors. IS-2 Stainless Steel Connector with Integral Strainer &bull A full line stainless steel strainer in the connector eliminates leak points and reduces installation time &bull A strainer that is not discarded when the trap is replaced &bull Easy strainer screen replacement &bull Optional blowdown valve &bull Accommodates Armstrong&rsquos inverted bucket, disc, thermostatic, thermostatic wafer, bimetallic, and float and thermostatic traps. Any manufacturer&rsquos 2-bolt steam trap can also be applied to Armstrong&rsquos S-2 connector. Standard 360&deg Stainless Steel Connector &bull A compact, lightweight assembly &bull Standardization, reducing inventory &bull A compact design, simplifying piping &bull Accommodates Armstrong&rsquos inverted bucket, disc, thermostatic, thermostatic wafer and bimetallic steam traps. Any manufacturer&rsquos 2-bolt steam trap can also be applied to Armstrong&rsquos standard connector.
$442.00 MSRP $ 346.19
Part #:706685

Steam Trap ConnectorsBesides 2000 Series stainless steel inverted bucket traps, the standard 360&deg connector or IS-2 connector with integral strainer can also be used on many Armstrong thermostatic, disc, bimetallic, and float and thermostatic traps. Any manufacturer&rsquos two-bolt steam traps can use Armstrong connectors. IS-2 Stainless Steel Connector with Integral Strainer &bull A full line stainless steel strainer in the connector eliminates leak points and reduces installation time &bull A strainer that is not discarded when the trap is replaced &bull Easy strainer screen replacement &bull Optional blowdown valve &bull Accommodates Armstrong&rsquos inverted bucket, disc, thermostatic, thermostatic wafer, bimetallic, and float and thermostatic traps. Any manufacturer&rsquos 2-bolt steam trap can also be applied to Armstrong&rsquos S-2 connector. Standard 360&deg Stainless Steel Connector &bull A compact, lightweight assembly &bull Standardization, reducing inventory &bull A compact design, simplifying piping &bull Accommodates Armstrong&rsquos inverted bucket, disc, thermostatic, thermostatic wafer and bimetallic steam traps. Any manufacturer&rsquos 2-bolt steam trap can also be applied to Armstrong&rsquos standard connector.
$347.00 MSRP $ 271.78
Part #:501-A21861

CD-33 Series Disc Steam TrapFor steam service up to 600 psig (42 barg) Capacities to 2,500 lb/hr (1,134 kg/hr). The Armstrong CD-33 is a disc-style trap designed to control the traps cycle rate. By reducing the cycle rate, the Armstrong CD-33 extends its service life well beyond that of typical disc traps. This enhanced performance minimizes maintenance time and greatly reduces steam costs. The CD-33 is designed with three discharge ports, which offer stable disc operation to extend operating life. The capacities of the Armstrong CD-33 have been engineered specifically for the following applications large steam main drips, process equipment and HVAC heating equipment on constant pressure. The CD-33L (low capacity) trap is designed for the low capacity applications of steam main drips and steam tracing lines. By ensuring that the capacities are designed to suit the applicationand are not oversizedthe CD-33 Series will last longer than other disc traps with excessive capacity ratings. Heres why &#8226 Three-discharge port design &#8226 Minimum wear with controlled cycling &#8226 Freeze resistant &#8226 Hardened seat and disc
$476.00 MSRP $ 365.85
Part #:501-A21862

CD-33 Series Disc Steam TrapFor steam service up to 600 psig (42 barg) Capacities to 2,500 lb/hr (1,134 kg/hr). The Armstrong CD-33 is a disc-style trap designed to control the traps cycle rate. By reducing the cycle rate, the Armstrong CD-33 extends its service life well beyond that of typical disc traps. This enhanced performance minimizes maintenance time and greatly reduces steam costs. The CD-33 is designed with three discharge ports, which offer stable disc operation to extend operating life. The capacities of the Armstrong CD-33 have been engineered specifically for the following applications large steam main drips, process equipment and HVAC heating equipment on constant pressure. The CD-33L (low capacity) trap is designed for the low capacity applications of steam main drips and steam tracing lines. By ensuring that the capacities are designed to suit the applicationand are not oversizedthe CD-33 Series will last longer than other disc traps with excessive capacity ratings. Heres why &#8226 Three-discharge port design &#8226 Minimum wear with controlled cycling &#8226 Freeze resistant &#8226 Hardened seat and disc
$523.00 MSRP $ 401.98
Part #:501-B2311C-1

Steam Trap ConnectorsBesides 2000 Series stainless steel inverted bucket traps, the standard 360 connector or IS-2 connector with integral strainer can also be used on many Armstrong thermostatic, disc, bimetallic, and float and thermostatic traps. Any manufacturers two-bolt steam traps can use Armstrong connectors. IS-2 Stainless Steel Connector with Integral Strainer &#8226 A full line stainless steel strainer in the connector eliminates leak points and reduces installation time &#8226 A strainer that is not discarded when the trap is replaced &#8226 Easy strainer screen replacement &#8226 Optional blowdown valve &#8226 Accommodates Armstrongs inverted bucket, disc, thermostatic, thermostatic wafer, bimetallic, and float and thermostatic traps. Any manufacturers 2-bolt steam trap can also be applied to Armstrongs S-2 connector. Standard 360 Stainless Steel Connector &#8226 A compact, lightweight assembly &#8226 Standardization, reducing inventory &#8226 A compact design, simplifying piping &#8226 Accommodates Armstrongs inverted bucket, disc, thermostatic, thermostatic wafer and bimetallic steam traps. Any manufacturers 2-bolt steam trap can also be applied to Armstrongs standard connector.
$218.10 MSRP $ 172.40
Part #:501-B2311C-2

Steam Trap ConnectorsBesides 2000 Series stainless steel inverted bucket traps, the standard 360 connector or IS-2 connector with integral strainer can also be used on many Armstrong thermostatic, disc, bimetallic, and float and thermostatic traps. Any manufacturers two-bolt steam traps can use Armstrong connectors. IS-2 Stainless Steel Connector with Integral Strainer &#8226 A full line stainless steel strainer in the connector eliminates leak points and reduces installation time &#8226 A strainer that is not discarded when the trap is replaced &#8226 Easy strainer screen replacement &#8226 Optional blowdown valve &#8226 Accommodates Armstrongs inverted bucket, disc, thermostatic, thermostatic wafer, bimetallic, and float and thermostatic traps. Any manufacturers 2-bolt steam trap can also be applied to Armstrongs S-2 connector. Standard 360 Stainless Steel Connector &#8226 A compact, lightweight assembly &#8226 Standardization, reducing inventory &#8226 A compact design, simplifying piping &#8226 Accommodates Armstrongs inverted bucket, disc, thermostatic, thermostatic wafer and bimetallic steam traps. Any manufacturers 2-bolt steam trap can also be applied to Armstrongs standard connector.
$218.10 MSRP $ 172.40
Part #:501-B2311D-1

Steam Trap ConnectorsBesides 2000 Series stainless steel inverted bucket traps, the standard 360 connector or IS-2 connector with integral strainer can also be used on many Armstrong thermostatic, disc, bimetallic, and float and thermostatic traps. Any manufacturers two-bolt steam traps can use Armstrong connectors. IS-2 Stainless Steel Connector with Integral Strainer &#8226 A full line stainless steel strainer in the connector eliminates leak points and reduces installation time &#8226 A strainer that is not discarded when the trap is replaced &#8226 Easy strainer screen replacement &#8226 Optional blowdown valve &#8226 Accommodates Armstrongs inverted bucket, disc, thermostatic, thermostatic wafer, bimetallic, and float and thermostatic traps. Any manufacturers 2-bolt steam trap can also be applied to Armstrongs S-2 connector. Standard 360 Stainless Steel Connector &#8226 A compact, lightweight assembly &#8226 Standardization, reducing inventory &#8226 A compact design, simplifying piping &#8226 Accommodates Armstrongs inverted bucket, disc, thermostatic, thermostatic wafer and bimetallic steam traps. Any manufacturers 2-bolt steam trap can also be applied to Armstrongs standard connector.
$218.10 MSRP $ 172.40
Part #:501-B2311D-2

Steam Trap ConnectorsBesides 2000 Series stainless steel inverted bucket traps, the standard 360 connector or IS-2 connector with integral strainer can also be used on many Armstrong thermostatic, disc, bimetallic, and float and thermostatic traps. Any manufacturers two-bolt steam traps can use Armstrong connectors. IS-2 Stainless Steel Connector with Integral Strainer &#8226 A full line stainless steel strainer in the connector eliminates leak points and reduces installation time &#8226 A strainer that is not discarded when the trap is replaced &#8226 Easy strainer screen replacement &#8226 Optional blowdown valve &#8226 Accommodates Armstrongs inverted bucket, disc, thermostatic, thermostatic wafer, bimetallic, and float and thermostatic traps. Any manufacturers 2-bolt steam trap can also be applied to Armstrongs S-2 connector. Standard 360 Stainless Steel Connector &#8226 A compact, lightweight assembly &#8226 Standardization, reducing inventory &#8226 A compact design, simplifying piping &#8226 Accommodates Armstrongs inverted bucket, disc, thermostatic, thermostatic wafer and bimetallic steam traps. Any manufacturers 2-bolt steam trap can also be applied to Armstrongs standard connector.
$218.10 MSRP $ 172.40
Part #:501-B4046

CD-40 and CD-60 Series Controlled Disc Steam TrapsFor pressures to 600 psig (41 barg) Capacities to 2,850 lb/hr (1 295 kg/hr) Armstrong CD-40 and CD-60 Series controlled disc traps contain a replaceable capsule, making it possible to renew a worn trap by simply replacing the capsule. A heating chamber in the shell ensures consistent operation. This steam jacket provides a relatively constant temperature in the control chamber regardless of ambient conditions. Cycling rate is controlled and does not increase when the trap is exposed to cold winds, rain or snow. CD-40 Series traps are also available with optional integral .045 perforated stainless steel strainer screens. CD-60 Series traps contain integral strainers with ratios of open area to inside area of pipe that equal or exceed those of most separate Y-type strainers.
$316.00 MSRP $ 249.80
 
Displaying: 1 - 24 of 1,982 Matching Items