Wiremold
Armstrong International


Displaying: 1 - 24 of 2,113 Matching Items
2,113 Items
View:
Active Filters :
Part #:300715

$0.90 MSRP $ 0.66
$18.99 MSRP $ 13.99
Part #:303116

$13.99 MSRP $ 10.46
Part #:303382

$21.99 MSRP $ 16.54
Part #:303383

$30.99 MSRP $ 23.12
Part #:706624

Inverted Bucket Steam TrapsEnergy efficient because it's so reliable The inverted bucket is the most reliable steam trap operating principle known. The heart of its simple design is a unique leverage system that multiplies the force provided by the bucket to open the valve against pressure. Since the bucket is open at the bottom, it resists damage from water hammer, and wear points are heavily reinforced for long life. The inverted bucket has only two moving parts-the valve lever assembly and the bucket. That means no fixed points, no complicated linkage. Nothing to stick, bind or clog. Conserves energy even in the presence of wear Armstrong inverted bucket steam traps open and close based on the difference in density between condensate and steam-the inverted bucket principle. They open and close gently, minimizing wear. This simple fact means that inverted buckets are subject to less wear than some other types of traps. In fact, as an Armstrong inverted bucket trap wears, its tight seal actually improves. The valve and seat of the Armstrong trap provide essentially line contact-resulting in a tight seal because the entire closing force is concentrated on one narrow seating ring. An Armstrong inverted bucket steam trap continues to operate efficiently with use. Gradual wear slightly increases the diameter of the seat and alters the shape and diameter of the valve. But, as this occurs, a tight seal is still preserved-the ball merely seats itself more deeply. Corrosion-resistant parts The stainless steel valve and seat of the Armstrong inverted bucket steam trap are individually ground and lapped together in matched sets. All other working parts are wear- and corrosion-resistant stainless steel. Venting of air and CO2 The Armstrong inverted bucket provides continuous automatic air and CO2 venting with no cooling lag or threat of air binding. Operation against back pressure The Armstrong inverted bucket has excellent performance against back pressure. It has no adverse effect on inverted bucket operation other than to reduce its capacity by the low differential. The bucket simply requires less force to pull the valve open and cycle the trap. Freedom from dirt problems Armstrong designed its inverted bucket to be virtually free of dirt problems. The valve and seat are at the top of the trap, far away from the larger particles of dirt, which fall to the bottom. Here, the up-and-down action of the bucket pulverizes them. Since the valve of an inverted bucket is either fully closed or open, dirt particles pass freely. And the swift flow of condensate from under the bucket's edge creates a unique self-scrubbing action that sweeps dirt out of the trap.
$494.00 MSRP $ 386.91
Part #:706681

Steam Trap ConnectorsBesides 2000 Series stainless steel inverted bucket traps, the standard 360&deg connector or IS-2 connector with integral strainer can also be used on many Armstrong thermostatic, disc, bimetallic, and float and thermostatic traps. Any manufacturer&rsquos two-bolt steam traps can use Armstrong connectors. IS-2 Stainless Steel Connector with Integral Strainer &bull A full line stainless steel strainer in the connector eliminates leak points and reduces installation time &bull A strainer that is not discarded when the trap is replaced &bull Easy strainer screen replacement &bull Optional blowdown valve &bull Accommodates Armstrong&rsquos inverted bucket, disc, thermostatic, thermostatic wafer, bimetallic, and float and thermostatic traps. Any manufacturer&rsquos 2-bolt steam trap can also be applied to Armstrong&rsquos S-2 connector. Standard 360&deg Stainless Steel Connector &bull A compact, lightweight assembly &bull Standardization, reducing inventory &bull A compact design, simplifying piping &bull Accommodates Armstrong&rsquos inverted bucket, disc, thermostatic, thermostatic wafer and bimetallic steam traps. Any manufacturer&rsquos 2-bolt steam trap can also be applied to Armstrong&rsquos standard connector.
$442.00 MSRP $ 346.19
Part #:708464

Steam Trap ConnectorsBesides 2000 Series stainless steel inverted bucket traps, the standard 360&deg connector or IS-2 connector with integral strainer can also be used on many Armstrong thermostatic, disc, bimetallic, and float and thermostatic traps. Any manufacturer&rsquos two-bolt steam traps can use Armstrong connectors. IS-2 Stainless Steel Connector with Integral Strainer &bull A full line stainless steel strainer in the connector eliminates leak points and reduces installation time &bull A strainer that is not discarded when the trap is replaced &bull Easy strainer screen replacement &bull Optional blowdown valve &bull Accommodates Armstrong&rsquos inverted bucket, disc, thermostatic, thermostatic wafer, bimetallic, and float and thermostatic traps. Any manufacturer&rsquos 2-bolt steam trap can also be applied to Armstrong&rsquos S-2 connector. Standard 360&deg Stainless Steel Connector &bull A compact, lightweight assembly &bull Standardization, reducing inventory &bull A compact design, simplifying piping &bull Accommodates Armstrong&rsquos inverted bucket, disc, thermostatic, thermostatic wafer and bimetallic steam traps. Any manufacturer&rsquos 2-bolt steam trap can also be applied to Armstrong&rsquos standard connector.
$347.00 MSRP $ 271.78
$316.99 MSRP $ 239.33
$2.99 MSRP $ 2.52
$4.99 MSRP $ 3.43
$3.99 MSRP $ 3.12
$3.99 MSRP $ 2.74
$10.99 MSRP $ 8.52
$3.81 MSRP $ 2.88
$119.00 MSRP $ 89.75
$89.00 MSRP $ 67.37
$104.00 MSRP $ 78.53
$6.00 MSRP $ 4.41
Part #:713360

Y-Type Cast Iron Strainers 250 lb Screwed 1/2"-3" Class 125 Flanged 2"-6" Class 250 Flanged 2"-6" Screen chambers won't leak or crush Both ends of the chambers are precisely machined. This means perfectly round and smooth seating surfaces, as well as a fixed chamber length. Since the screen seats snugly on the machined surface, no particle bigger than the screen opening can escape around the end of the screen. Screwed retainers easy in, easy out Straight threads mean it takes less torque to achieve a tight seal with proper gasket compression. Less torque is also required to remove the retainer. For you, that means less danger of "freezing in" than with hard-to-break tapered pipe threads. Off-center blowdown connections for better dirt removal Off-center drains on 2-1/2" and 3" strainers allow you to remove liquid and dirt nearly completely when blowing down the strainer. Also, less liquid will spill when the screen retainer is removed. Many screen choices Many screen materials, meshes and perforations are available.
$28.00 MSRP $ 21.52
Part #:713363

Y-Type Cast Iron Strainers 250 lb Screwed 1/2"-3" Class 125 Flanged 2"-6" Class 250 Flanged 2"-6" Screen chambers won't leak or crush Both ends of the chambers are precisely machined. This means perfectly round and smooth seating surfaces, as well as a fixed chamber length. Since the screen seats snugly on the machined surface, no particle bigger than the screen opening can escape around the end of the screen. Screwed retainers easy in, easy out Straight threads mean it takes less torque to achieve a tight seal with proper gasket compression. Less torque is also required to remove the retainer. For you, that means less danger of "freezing in" than with hard-to-break tapered pipe threads. Off-center blowdown connections for better dirt removal Off-center drains on 2-1/2" and 3" strainers allow you to remove liquid and dirt nearly completely when blowing down the strainer. Also, less liquid will spill when the screen retainer is removed. Many screen choices Many screen materials, meshes and perforations are available.
$74.00 MSRP $ 56.79
Part #:713364

Y-Type Cast Iron Strainers 250 lb Screwed 1/2"-3" Class 125 Flanged 2"-6" Class 250 Flanged 2"-6" Screen chambers won't leak or crush Both ends of the chambers are precisely machined. This means perfectly round and smooth seating surfaces, as well as a fixed chamber length. Since the screen seats snugly on the machined surface, no particle bigger than the screen opening can escape around the end of the screen. Screwed retainers easy in, easy out Straight threads mean it takes less torque to achieve a tight seal with proper gasket compression. Less torque is also required to remove the retainer. For you, that means less danger of "freezing in" than with hard-to-break tapered pipe threads. Off-center blowdown connections for better dirt removal Off-center drains on 2-1/2" and 3" strainers allow you to remove liquid and dirt nearly completely when blowing down the strainer. Also, less liquid will spill when the screen retainer is removed. Many screen choices Many screen materials, meshes and perforations are available.
$70.00 MSRP $ 53.80
 
Displaying: 1 - 24 of 2,113 Matching Items