Thermostatic Traps
Steam and Filter Products
View:
Active Filters :
- Main Category: Steam and Filter Products
- Steam Traps: Thermostatic Traps Trap Valve Stations
Part #:501-B7863
- Bimetallic Superheat Steam TrapsBimetallic steam traps have the ability to handle large start-up loads. As the system increases in temperature and pressure, the traps stacked nickel-chrome bimetallic elements start to expand, allowing for tight shutoff as steam reaches the trap, thus preventing steam loss.
The bimetallic trap offers resistance to water hammer. A titanium valve and seat on high-pressure bimetallic traps ensure extremely long service life in the harsh environment of superheated steam systems.
Qty:
Part #:501-C4448-1
- Thermostatic Wafer Steam TrapsArmstrong offers several thermostatic wafer steam traps. The WT-1 is ideal for low-capacity steam tracers and features an exclusive non-welded wafer design, a sealed stainless steel body and an internal strainer screen two to three times larger than that of other thermostatic traps. Choose from NPT or BSPT screwed connections.
The WT-2000 is adaptable to a 360 connector to expand piping options and simplify installation. Choose NPT or BSPT screwed or socketweld connections. The WT-2000 is also available for use on the IS-2 stainless steel connector with integral strainer. It can also be used with the TVS 4000.
Armstrongs WT-3 is a carbon steel thermostatic wafer trap for superheated drip service. It features an exclusive non-welded wafer design, which eliminates problems associated with weld stress. The WT-3 has no thin-walled enclosures such as bellows or welded diaphragms. It is also resistant to water hammer. Choose NPT or BSPT screwed or socketweld connections.
The Series MT from Armstrong is sized precisely to accommodate the extremely low condensate loads found in most instrument steam tracer lines.
NOTE Since the normal operation of all suppressed temperature-discharge (subcooling) steam traps is to back up condensate, they should not be used on drip legs for saturated steam service, heating or process equipment. Exercise care in the maintenance of any thermostatic wafer trap with a small discharge area susceptible to clogging.
Qty:
Part #:501-D15977
- Thermostatic Wafer Steam TrapsArmstrong offers several thermostatic wafer steam traps. The WT-1 is ideal for low-capacity steam tracers and features an exclusive non-welded wafer design, a sealed stainless steel body and an internal strainer screen two to three times larger than that of other thermostatic traps. Choose from NPT or BSPT screwed connections.
The WT-2000 is adaptable to a 360 connector to expand piping options and simplify installation. Choose NPT or BSPT screwed or socketweld connections. The WT-2000 is also available for use on the IS-2 stainless steel connector with integral strainer. It can also be used with the TVS 4000.
Armstrongs WT-3 is a carbon steel thermostatic wafer trap for superheated drip service. It features an exclusive non-welded wafer design, which eliminates problems associated with weld stress. The WT-3 has no thin-walled enclosures such as bellows or welded diaphragms. It is also resistant to water hammer. Choose NPT or BSPT screwed or socketweld connections.
The Series MT from Armstrong is sized precisely to accommodate the extremely low condensate loads found in most instrument steam tracer lines.
NOTE Since the normal operation of all suppressed temperature-discharge (subcooling) steam traps is to back up condensate, they should not be used on drip legs for saturated steam service, heating or process equipment. Exercise care in the maintenance of any thermostatic wafer trap with a small discharge area susceptible to clogging.
Qty:
Part #:501-D3609
- TVS 4000 Series Stainless Steel Trap Valve Station
Stainless Steel
The stainless steel version of the remarkable Armstrong Trap Valve Station (TVS) gives you two piston-style isolation valves, a test valve and an integral stainless steel strainer with blowdown valveall merged in a single, versatile package. Whats more, the unique Armstrong connector makes the TVS compatible with all of these
• Inverted bucket
• Disc
• Thermostatic
• Thermostatic wafer
• Bimetallic
• Float and thermostatic
• Two-bolt steam traps from other manufacturersWith Armstrongs Trap Valve Station, youll profit from all of these benefits
• Reduced costs. TVS saves by eliminating potential leak points and reducing installation and maintenance time.
• Multiple functions. TVS has test and strainer blowdown valves. When installed with Armstrong Model 2011 and 2022 steam traps, it will also accommodate the Armstrong pop drain, and SteamEyeremote steam trap monitoring and testing devices.
• Reduced design time. Permits combining products with exact face-to-face dimensions.
• Three-year guarantee. The TVS is guaranteed for three years.
• Easy, in-line repairability with maximum safety. TVS allows isolation at point of service with upstream/downstream depressurization.
• Installation versatility. The TVS is adaptable to any manufacturers two-bolt steam trap and piping configuration.
• Simplified trap testing. You get enhanced capability to check trap operation and a built-in method to block and bleed traps.
Qty:
Part #:501-D3611
- TVS 4000 Series Stainless Steel Trap Valve Station
Stainless Steel
The stainless steel version of the remarkable Armstrong Trap Valve Station (TVS) gives you two piston-style isolation valves, a test valve and an integral stainless steel strainer with blowdown valveall merged in a single, versatile package. Whats more, the unique Armstrong connector makes the TVS compatible with all of these
• Inverted bucket
• Disc
• Thermostatic
• Thermostatic wafer
• Bimetallic
• Float and thermostatic
• Two-bolt steam traps from other manufacturersWith Armstrongs Trap Valve Station, youll profit from all of these benefits
• Reduced costs. TVS saves by eliminating potential leak points and reducing installation and maintenance time.
• Multiple functions. TVS has test and strainer blowdown valves. When installed with Armstrong Model 2011 and 2022 steam traps, it will also accommodate the Armstrong pop drain, and SteamEyeremote steam trap monitoring and testing devices.
• Reduced design time. Permits combining products with exact face-to-face dimensions.
• Three-year guarantee. The TVS is guaranteed for three years.
• Easy, in-line repairability with maximum safety. TVS allows isolation at point of service with upstream/downstream depressurization.
• Installation versatility. The TVS is adaptable to any manufacturers two-bolt steam trap and piping configuration.
• Simplified trap testing. You get enhanced capability to check trap operation and a built-in method to block and bleed traps.
Qty:
Part #:501-D3612
- TVS 4000 Series Stainless Steel Trap Valve Station
Stainless Steel
The stainless steel version of the remarkable Armstrong Trap Valve Station (TVS) gives you two piston-style isolation valves, a test valve and an integral stainless steel strainer with blowdown valveall merged in a single, versatile package. Whats more, the unique Armstrong connector makes the TVS compatible with all of these
• Inverted bucket
• Disc
• Thermostatic
• Thermostatic wafer
• Bimetallic
• Float and thermostatic
• Two-bolt steam traps from other manufacturersWith Armstrongs Trap Valve Station, youll profit from all of these benefits
• Reduced costs. TVS saves by eliminating potential leak points and reducing installation and maintenance time.
• Multiple functions. TVS has test and strainer blowdown valves. When installed with Armstrong Model 2011 and 2022 steam traps, it will also accommodate the Armstrong pop drain, and SteamEyeremote steam trap monitoring and testing devices.
• Reduced design time. Permits combining products with exact face-to-face dimensions.
• Three-year guarantee. The TVS is guaranteed for three years.
• Easy, in-line repairability with maximum safety. TVS allows isolation at point of service with upstream/downstream depressurization.
• Installation versatility. The TVS is adaptable to any manufacturers two-bolt steam trap and piping configuration.
• Simplified trap testing. You get enhanced capability to check trap operation and a built-in method to block and bleed traps.
Qty:
Part #:501-D4802
- TVS 4000F Series Stainless Steel Trap Valve Station
Stainless Steel
A complete package featuring two piston-style isolation valves, test valve and integral stainless steel strainer with blowdown valve. You'll realize all the benefits of a piston valve integrated into the same space-saving package.br
Features
• Reduced costs. TVS saves by eliminating potential leak points and reducing installation and maintenance time.
• Multiple functions. TVS has test and strainer blowdown valves. When installed with Armstrong Model 2011 and 2022 steam traps, it will also accommodate the Armstrong pop drain, and SteamEyeremote steam trap monitoring and testing devices.
• Reduced design time. Permits combining products with exact face-to-face dimensions.
• Three-year guarantee. The TVS is guaranteed for three years.
• Easy, in-line repairability with maximum safety. TVS allows isolation at point of service with upstream/downstream depressurization.
• Installation versatility. The TVS is adaptable to any manufacturers two-bolt steam trap and piping configuration.
• Simplified trap testing. You get enhanced capability to check trap operation and a built-in method to block and bleed traps. • Integral Flanges. The body and connections are of one piece construction, free of welds and other potential leak paths.
Qty:
Part #:501-D4803
- TVS 4000F Series Stainless Steel Trap Valve Station
Stainless Steel
A complete package featuring two piston-style isolation valves, test valve and integral stainless steel strainer with blowdown valve. You'll realize all the benefits of a piston valve integrated into the same space-saving package.br
Features
• Reduced costs. TVS saves by eliminating potential leak points and reducing installation and maintenance time.
• Multiple functions. TVS has test and strainer blowdown valves. When installed with Armstrong Model 2011 and 2022 steam traps, it will also accommodate the Armstrong pop drain, and SteamEyeremote steam trap monitoring and testing devices.
• Reduced design time. Permits combining products with exact face-to-face dimensions.
• Three-year guarantee. The TVS is guaranteed for three years.
• Easy, in-line repairability with maximum safety. TVS allows isolation at point of service with upstream/downstream depressurization.
• Installation versatility. The TVS is adaptable to any manufacturers two-bolt steam trap and piping configuration.
• Simplified trap testing. You get enhanced capability to check trap operation and a built-in method to block and bleed traps. • Integral Flanges. The body and connections are of one piece construction, free of welds and other potential leak paths.
Qty:
Part #:501-D4976
- TVS 4000 Series Stainless Steel Trap Valve Station
Stainless Steel
The stainless steel version of the remarkable Armstrong Trap Valve Station (TVS) gives you two piston-style isolation valves, a test valve and an integral stainless steel strainer with blowdown valveall merged in a single, versatile package. Whats more, the unique Armstrong connector makes the TVS compatible with all of these
• Inverted bucket
• Disc
• Thermostatic
• Thermostatic wafer
• Bimetallic
• Float and thermostatic
• Two-bolt steam traps from other manufacturersWith Armstrongs Trap Valve Station, youll profit from all of these benefits
• Reduced costs. TVS saves by eliminating potential leak points and reducing installation and maintenance time.
• Multiple functions. TVS has test and strainer blowdown valves. When installed with Armstrong Model 2011 and 2022 steam traps, it will also accommodate the Armstrong pop drain, and SteamEyeremote steam trap monitoring and testing devices.
• Reduced design time. Permits combining products with exact face-to-face dimensions.
• Three-year guarantee. The TVS is guaranteed for three years.
• Easy, in-line repairability with maximum safety. TVS allows isolation at point of service with upstream/downstream depressurization.
• Installation versatility. The TVS is adaptable to any manufacturers two-bolt steam trap and piping configuration.
• Simplified trap testing. You get enhanced capability to check trap operation and a built-in method to block and bleed traps.
Qty:
Part #:501-D4977
- TVS 4000 Series Stainless Steel Trap Valve Station
Stainless Steel
The stainless steel version of the remarkable Armstrong Trap Valve Station (TVS) gives you two piston-style isolation valves, a test valve and an integral stainless steel strainer with blowdown valveall merged in a single, versatile package. Whats more, the unique Armstrong connector makes the TVS compatible with all of these
• Inverted bucket
• Disc
• Thermostatic
• Thermostatic wafer
• Bimetallic
• Float and thermostatic
• Two-bolt steam traps from other manufacturersWith Armstrongs Trap Valve Station, youll profit from all of these benefits
• Reduced costs. TVS saves by eliminating potential leak points and reducing installation and maintenance time.
• Multiple functions. TVS has test and strainer blowdown valves. When installed with Armstrong Model 2011 and 2022 steam traps, it will also accommodate the Armstrong pop drain, and SteamEyeremote steam trap monitoring and testing devices.
• Reduced design time. Permits combining products with exact face-to-face dimensions.
• Three-year guarantee. The TVS is guaranteed for three years.
• Easy, in-line repairability with maximum safety. TVS allows isolation at point of service with upstream/downstream depressurization.
• Installation versatility. The TVS is adaptable to any manufacturers two-bolt steam trap and piping configuration.
• Simplified trap testing. You get enhanced capability to check trap operation and a built-in method to block and bleed traps.
Qty:
Part #:501-D4978
- TVS 4000 Series Stainless Steel Trap Valve Station
Stainless Steel
The stainless steel version of the remarkable Armstrong Trap Valve Station (TVS) gives you two piston-style isolation valves, a test valve and an integral stainless steel strainer with blowdown valveall merged in a single, versatile package. Whats more, the unique Armstrong connector makes the TVS compatible with all of these
• Inverted bucket
• Disc
• Thermostatic
• Thermostatic wafer
• Bimetallic
• Float and thermostatic
• Two-bolt steam traps from other manufacturersWith Armstrongs Trap Valve Station, youll profit from all of these benefits
• Reduced costs. TVS saves by eliminating potential leak points and reducing installation and maintenance time.
• Multiple functions. TVS has test and strainer blowdown valves. When installed with Armstrong Model 2011 and 2022 steam traps, it will also accommodate the Armstrong pop drain, and SteamEyeremote steam trap monitoring and testing devices.
• Reduced design time. Permits combining products with exact face-to-face dimensions.
• Three-year guarantee. The TVS is guaranteed for three years.
• Easy, in-line repairability with maximum safety. TVS allows isolation at point of service with upstream/downstream depressurization.
• Installation versatility. The TVS is adaptable to any manufacturers two-bolt steam trap and piping configuration.
• Simplified trap testing. You get enhanced capability to check trap operation and a built-in method to block and bleed traps.
Qty:
Part #:501-D4979
- TVS 4000 Series Stainless Steel Trap Valve Station
Stainless Steel
The stainless steel version of the remarkable Armstrong Trap Valve Station (TVS) gives you two piston-style isolation valves, a test valve and an integral stainless steel strainer with blowdown valveall merged in a single, versatile package. Whats more, the unique Armstrong connector makes the TVS compatible with all of these
• Inverted bucket
• Disc
• Thermostatic
• Thermostatic wafer
• Bimetallic
• Float and thermostatic
• Two-bolt steam traps from other manufacturersWith Armstrongs Trap Valve Station, youll profit from all of these benefits
• Reduced costs. TVS saves by eliminating potential leak points and reducing installation and maintenance time.
• Multiple functions. TVS has test and strainer blowdown valves. When installed with Armstrong Model 2011 and 2022 steam traps, it will also accommodate the Armstrong pop drain, and SteamEyeremote steam trap monitoring and testing devices.
• Reduced design time. Permits combining products with exact face-to-face dimensions.
• Three-year guarantee. The TVS is guaranteed for three years.
• Easy, in-line repairability with maximum safety. TVS allows isolation at point of service with upstream/downstream depressurization.
• Installation versatility. The TVS is adaptable to any manufacturers two-bolt steam trap and piping configuration.
• Simplified trap testing. You get enhanced capability to check trap operation and a built-in method to block and bleed traps.
Qty:
Part #:501-D500551
- Thermostatic Wafer Steam TrapsArmstrong offers several thermostatic wafer steam traps. The WT-1 is ideal for low-capacity steam tracers and features an exclusive non-welded wafer design, a sealed stainless steel body and an internal strainer screen two to three times larger than that of other thermostatic traps. Choose from NPT or BSPT screwed connections.
The WT-2000 is adaptable to a 360 connector to expand piping options and simplify installation. Choose NPT or BSPT screwed or socketweld connections. The WT-2000 is also available for use on the IS-2 stainless steel connector with integral strainer. It can also be used with the TVS 4000.
Armstrongs WT-3 is a carbon steel thermostatic wafer trap for superheated drip service. It features an exclusive non-welded wafer design, which eliminates problems associated with weld stress. The WT-3 has no thin-walled enclosures such as bellows or welded diaphragms. It is also resistant to water hammer. Choose NPT or BSPT screwed or socketweld connections.
The Series MT from Armstrong is sized precisely to accommodate the extremely low condensate loads found in most instrument steam tracer lines.
NOTE Since the normal operation of all suppressed temperature-discharge (subcooling) steam traps is to back up condensate, they should not be used on drip legs for saturated steam service, heating or process equipment. Exercise care in the maintenance of any thermostatic wafer trap with a small discharge area susceptible to clogging.
Qty:
Part #:501-D501413
- Thermostatic Wafer Steam TrapsArmstrong offers several thermostatic wafer steam traps. The WT-1 is ideal for low-capacity steam tracers and features an exclusive non-welded wafer design, a sealed stainless steel body and an internal strainer screen two to three times larger than that of other thermostatic traps. Choose from NPT or BSPT screwed connections.
The WT-2000 is adaptable to a 360 connector to expand piping options and simplify installation. Choose NPT or BSPT screwed or socketweld connections. The WT-2000 is also available for use on the IS-2 stainless steel connector with integral strainer. It can also be used with the TVS 4000.
Armstrongs WT-3 is a carbon steel thermostatic wafer trap for superheated drip service. It features an exclusive non-welded wafer design, which eliminates problems associated with weld stress. The WT-3 has no thin-walled enclosures such as bellows or welded diaphragms. It is also resistant to water hammer. Choose NPT or BSPT screwed or socketweld connections.
The Series MT from Armstrong is sized precisely to accommodate the extremely low condensate loads found in most instrument steam tracer lines.
NOTE Since the normal operation of all suppressed temperature-discharge (subcooling) steam traps is to back up condensate, they should not be used on drip legs for saturated steam service, heating or process equipment. Exercise care in the maintenance of any thermostatic wafer trap with a small discharge area susceptible to clogging.
Qty:
Part #:501-D501581
- Thermostatic Wafer Steam TrapsArmstrong offers several thermostatic wafer steam traps. The WT-1 is ideal for low-capacity steam tracers and features an exclusive non-welded wafer design, a sealed stainless steel body and an internal strainer screen two to three times larger than that of other thermostatic traps. Choose from NPT or BSPT screwed connections.
The WT-2000 is adaptable to a 360 connector to expand piping options and simplify installation. Choose NPT or BSPT screwed or socketweld connections. The WT-2000 is also available for use on the IS-2 stainless steel connector with integral strainer. It can also be used with the TVS 4000.
Armstrongs WT-3 is a carbon steel thermostatic wafer trap for superheated drip service. It features an exclusive non-welded wafer design, which eliminates problems associated with weld stress. The WT-3 has no thin-walled enclosures such as bellows or welded diaphragms. It is also resistant to water hammer. Choose NPT or BSPT screwed or socketweld connections.
The Series MT from Armstrong is sized precisely to accommodate the extremely low condensate loads found in most instrument steam tracer lines.
NOTE Since the normal operation of all suppressed temperature-discharge (subcooling) steam traps is to back up condensate, they should not be used on drip legs for saturated steam service, heating or process equipment. Exercise care in the maintenance of any thermostatic wafer trap with a small discharge area susceptible to clogging.
Qty:
Part #:501-D502941
- Thermostatic Wafer Steam TrapsArmstrong offers several thermostatic wafer steam traps. The WT-1 is ideal for low-capacity steam tracers and features an exclusive non-welded wafer design, a sealed stainless steel body and an internal strainer screen two to three times larger than that of other thermostatic traps. Choose from NPT or BSPT screwed connections.
The WT-2000 is adaptable to a 360 connector to expand piping options and simplify installation. Choose NPT or BSPT screwed or socketweld connections. The WT-2000 is also available for use on the IS-2 stainless steel connector with integral strainer. It can also be used with the TVS 4000.
Armstrongs WT-3 is a carbon steel thermostatic wafer trap for superheated drip service. It features an exclusive non-welded wafer design, which eliminates problems associated with weld stress. The WT-3 has no thin-walled enclosures such as bellows or welded diaphragms. It is also resistant to water hammer. Choose NPT or BSPT screwed or socketweld connections.
The Series MT from Armstrong is sized precisely to accommodate the extremely low condensate loads found in most instrument steam tracer lines.
NOTE Since the normal operation of all suppressed temperature-discharge (subcooling) steam traps is to back up condensate, they should not be used on drip legs for saturated steam service, heating or process equipment. Exercise care in the maintenance of any thermostatic wafer trap with a small discharge area susceptible to clogging.
Qty:
Part #:501-D505364
- Thermostatic Wafer Steam TrapsArmstrong offers several thermostatic wafer steam traps. The WT-1 is ideal for low-capacity steam tracers and features an exclusive non-welded wafer design, a sealed stainless steel body and an internal strainer screen two to three times larger than that of other thermostatic traps. Choose from NPT or BSPT screwed connections.
The WT-2000 is adaptable to a 360 connector to expand piping options and simplify installation. Choose NPT or BSPT screwed or socketweld connections. The WT-2000 is also available for use on the IS-2 stainless steel connector with integral strainer. It can also be used with the TVS 4000.
Armstrongs WT-3 is a carbon steel thermostatic wafer trap for superheated drip service. It features an exclusive non-welded wafer design, which eliminates problems associated with weld stress. The WT-3 has no thin-walled enclosures such as bellows or welded diaphragms. It is also resistant to water hammer. Choose NPT or BSPT screwed or socketweld connections.
The Series MT from Armstrong is sized precisely to accommodate the extremely low condensate loads found in most instrument steam tracer lines.
NOTE Since the normal operation of all suppressed temperature-discharge (subcooling) steam traps is to back up condensate, they should not be used on drip legs for saturated steam service, heating or process equipment. Exercise care in the maintenance of any thermostatic wafer trap with a small discharge area susceptible to clogging.
Qty:
Part #:501-D541398
- Thermostatic Wafer Steam TrapsArmstrong offers several thermostatic wafer steam traps. The WT-1 is ideal for low-capacity steam tracers and features an exclusive non-welded wafer design, a sealed stainless steel body and an internal strainer screen two to three times larger than that of other thermostatic traps. Choose from NPT or BSPT screwed connections.
The WT-2000 is adaptable to a 360 connector to expand piping options and simplify installation. Choose NPT or BSPT screwed or socketweld connections. The WT-2000 is also available for use on the IS-2 stainless steel connector with integral strainer. It can also be used with the TVS 4000.
Armstrongs WT-3 is a carbon steel thermostatic wafer trap for superheated drip service. It features an exclusive non-welded wafer design, which eliminates problems associated with weld stress. The WT-3 has no thin-walled enclosures such as bellows or welded diaphragms. It is also resistant to water hammer. Choose NPT or BSPT screwed or socketweld connections.
The Series MT from Armstrong is sized precisely to accommodate the extremely low condensate loads found in most instrument steam tracer lines.
NOTE Since the normal operation of all suppressed temperature-discharge (subcooling) steam traps is to back up condensate, they should not be used on drip legs for saturated steam service, heating or process equipment. Exercise care in the maintenance of any thermostatic wafer trap with a small discharge area susceptible to clogging.
Qty:
Part #:513610
- TVS 4000 Series Stainless Steel Trap Valve Station
Stainless Steel
The stainless steel version of the remarkable Armstrong Trap Valve Station (TVS) gives you two piston-style isolation valves, a test valve and an integral stainless steel strainer with blowdown valveall merged in a single, versatile package. Whats more, the unique Armstrong connector makes the TVS compatible with all of these
• Inverted bucket
• Disc
• Thermostatic
• Thermostatic wafer
• Bimetallic
• Float and thermostatic
• Two-bolt steam traps from other manufacturersWith Armstrongs Trap Valve Station, youll profit from all of these benefits
• Reduced costs. TVS saves by eliminating potential leak points and reducing installation and maintenance time.
• Multiple functions. TVS has test and strainer blowdown valves. When installed with Armstrong Model 2011 and 2022 steam traps, it will also accommodate the Armstrong pop drain, and SteamEyeremote steam trap monitoring and testing devices.
• Reduced design time. Permits combining products with exact face-to-face dimensions.
• Three-year guarantee. The TVS is guaranteed for three years.
• Easy, in-line repairability with maximum safety. TVS allows isolation at point of service with upstream/downstream depressurization.
• Installation versatility. The TVS is adaptable to any manufacturers two-bolt steam trap and piping configuration.
• Simplified trap testing. You get enhanced capability to check trap operation and a built-in method to block and bleed traps.
Qty:
Displaying: 1 - 19 of 19 Matching Items