1/2in
1-1/4in x 1-1/2in
View:
Active Filters :
- Size: 1-1/4in x 1-1/2in 1/2in 17 Quart 24in
- Material: Aluminum Cast Iron Ductile Iron Plastic Poly/Plastic PVC 40 PVC DWV
Part #:300515
- Appleton Form 85 Unilets Conduit Outlet Bodies Covers and Gaskets are used to connect and change direction of conduit runs. In addition to making bends in a conduit system they allow connections for branch runs. These conduit bodies serve as pulling fittings and permit access to conductors for splicing and maintenance.
Qty:
$
2.01
Qty:
Qty:
Part #:521536
- In-Line Lubricator Attributes
Maximum Operating Pressure
500 PSI at 70°F (21°C)
Weight
0.88 lb
Female Thread Size Metric
15mm
Material
Aluminum
Capacity
1.4 fluid oz. oil (40ml)
Female Thread
NPT
Flow
30 SCFM
Female Thread Size
1/2"
$
80.44
Qty:
Part #:301990
- Appleton Form 85 Unilets Conduit Outlet Bodies Covers and Gaskets are used to connect and change direction of conduit runs. In addition to making bends in a conduit system they allow connections for branch runs. These conduit bodies serve as pulling fittings and permit access to conductors for splicing and maintenance.
Qty:
Part #:302195
- Appleton Form 85 Unilets Conduit Outlet Bodies Covers and Gaskets are used to connect and change direction of conduit runs. In addition to making bends in a conduit system they allow connections for branch runs. These conduit bodies serve as pulling fittings and permit access to conductors for splicing and maintenance.
Qty:
Qty:
Qty:
Qty:
Part #:713360
-
Y-Type Cast Iron Strainers
250 lb Screwed 1/2"-3" Class 125 Flanged 2"-6" Class 250 Flanged 2"-6"
Screen chambers won't leak or crush
Both ends of the chambers are precisely machined. This means perfectly round and smooth seating surfaces, as well as a fixed chamber length. Since the screen seats snugly on the machined surface, no particle bigger than the screen opening can escape around the end of the screen.
Screwed retainers easy in, easy out
Straight threads mean it takes less torque to achieve a tight seal with proper gasket compression. Less torque is also required to remove the retainer. For you, that means less danger of "freezing in" than with hard-to-break tapered pipe threads.
Off-center blowdown connections for better dirt removal
Off-center drains on 2-1/2" and 3" strainers allow you to remove liquid and dirt nearly completely when blowing down the strainer. Also, less liquid will spill when the screen retainer is removed.
Many screen choices
Many screen materials, meshes and perforations are available.
Qty:
Qty:
Qty:
Part #:301957
- Appleton Form 85 Unilets Conduit Outlet Bodies Covers and Gaskets are used to connect and change direction of conduit runs. In addition to making bends in a conduit system they allow connections for branch runs. These conduit bodies serve as pulling fittings and permit access to conductors for splicing and maintenance.
Qty:
Part #:302152
- Appleton Form 85 Unilets Conduit Outlet Bodies Covers and Gaskets are used to connect and change direction of conduit runs. In addition to making bends in a conduit system they allow connections for branch runs. These conduit bodies serve as pulling fittings and permit access to conductors for splicing and maintenance.
Qty:
Part #:302172
- Appleton Form 85 Unilets Conduit Outlet Bodies Covers and Gaskets are used to connect and change direction of conduit runs. In addition to making bends in a conduit system they allow connections for branch runs. These conduit bodies serve as pulling fittings and permit access to conductors for splicing and maintenance.
Qty:
Part #:501644
- Double Utility Pail, 17qt, Gray
RCP2617GRA
Be the first to write a review
Double pail allows you to separate cleaning solution from your rinse water.
Molded-in graduations.
Wide pour spout.
Durable, molded plastic.
$
50.83
Qty:
Part #:701257
- The most reliable steam trap known&mdashthe inverted bucket&mdashprovides efficientcondensate drainage of virtually all types of steam-using equipment. Putthe inverted bucket to work in a tough cast iron package, and you have thebest of both worlds. Because they operate efficiently for longer periods oftime, Armstrong cast iron inverted buckets add solid energy savings to lowerreplacement/labor costs. All Armstrong cast iron inverted bucket steam trapsare repairable for even bigger maintenance savings.
A unique leverage system multiplies the force provided by the bucket to openthe valve against system pressure. The mechanism is free-floating, and hasno fixed pivots to create wear or friction.
Because the mechanism is located at the top of the trap, no dirt can collecton the orifice. Small particles of dirt are held in suspension until dischargedby the full differential purging action when the bucket sinks, pulling the valveoff the seat.
The discharge orifice is surrounded by a water seal, preventing live steamloss. Automatic air venting is provided by a small vent hole in the bucket, whichprovides continuous automatic air and CO2 venting at steam temperature.Inverted bucket traps drain continuously, although discharging intermittently,allowing no condensate backup. They are also resistant to water hammer.
Qty:
Qty:
Qty:
Qty:
Displaying: 1 - 24 of 122 Matching Items