G 1/2 B x 1/2 in. Male National Pipe Thread (MNPT) with 1/4 in. Female National Pipe Thread (FNPT)
37deg Flare JIC Swivel x FNPT
View:
Active Filters :
Qty:
Qty:
Qty:
Qty:
Part #:1128-12 G6X-S
- Performance Characteristics
Connection Type
37° Flare
Industry Standards
SAE J514
Maximum Dynamic Pressure (psi)
4000
Shape
Straight
Connection Style
Tube to NPT
Connection 1 Style
Female 37° Flare Swivel
Connection 1 Tube O.D. (inch)
3/4
Connection 1 Tube O.D. (mm)
18, 20
Connection 2 Style
Female NPT/NPTF
Connection 2 Tube O.D. (inch)
na
Connection 2 Tube O.D. (mm)
na
Connection 2 Thread Size (inch)
3/4-14
Connection 2 Thread Size (mm)
na
Connection 3 Style
na
Connection 3 Tube O.D. (inch)
na
Connection 3 Tube O.D. (mm)
na
Connection 3 Thread Size (inch)
na
Connection 3 Thread Size (mm)
na
Connection 4 Style
na
Connection 4 Tube O.D. (inch)
na
Connection 4 Tube O.D. (mm)
na
O-Ring Material
na
Body Material
Steel, Chromium-6 Free
Qty:
$
7.43
Qty:
Part #:1128-8 G6X-S
- Performance Characteristics
Connection Type
37° Flare
Industry Standards
SAE J514
Maximum Dynamic Pressure (psi)
5000
Shape
Straight
Connection Style
Tube to NPT
Connection 1 Style
Female 37° Flare Swivel
Connection 1 Tube O.D. (inch)
1/2
Connection 1 Tube O.D. (mm)
12
Connection 2 Style
Female NPT/NPTF
Connection 2 Tube O.D. (inch)
na
Connection 2 Tube O.D. (mm)
na
Connection 2 Thread Size (inch)
1/2-14
Connection 2 Thread Size (mm)
na
Connection 3 Style
na
Connection 3 Tube O.D. (inch)
na
Connection 3 Tube O.D. (mm)
na
Connection 3 Thread Size (inch)
na
Connection 3 Thread Size (mm)
na
Connection 4 Style
na
Connection 4 Tube O.D. (inch)
na
Connection 4 Tube O.D. (mm)
na
O-Ring Material
na
Body Material
Steel, Chromium-6 Free
$
7.94
Qty:
Part #:1267-612-100-1-1-T-15
- Additional InformationCE compliant to suppress RFI, EMI and ESDIdeal for applications including irrigation, tank monitoring, water & wastewater and well head measurementLimitations Which Apply AreThese units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation.In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice.
Qty:
Part #:1267-612-100-1-1-T-25
- Additional InformationCE compliant to suppress RFI, EMI and ESDIdeal for applications including irrigation, tank monitoring, water & wastewater and well head measurementLimitations Which Apply AreThese units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation.In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice.
Qty:
Part #:1267-612-100-1-1-T-75
- Additional InformationCE compliant to suppress RFI, EMI and ESDIdeal for applications including irrigation, tank monitoring, water & wastewater and well head measurementLimitations Which Apply AreThese units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation.In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice.
Qty:
Part #:1267-612-1000-1-1-T-5
- Additional InformationCE compliant to suppress RFI, EMI and ESDIdeal for applications including irrigation, tank monitoring, water & wastewater and well head measurementLimitations Which Apply AreThese units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation.In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice.
Qty:
Part #:1267-612-300-1-1-T-15
- Additional InformationCE compliant to suppress RFI, EMI and ESDIdeal for applications including irrigation, tank monitoring, water & wastewater and well head measurementLimitations Which Apply AreThese units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation.In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice.
Qty:
Displaying: 1 - 12 of 12 Matching Items