37deg Flare JIC x SAE-ORB
1/2 in. Male National Pipe Thread (MNPT)
View:
Active Filters :
- End Connection: 1/2 in. Male National Pipe Thread (MNPT) 37deg Flare JIC x SAE-ORB
Qty:
Qty:
Part #:1128-8-4 C5OX-S
Qty:
Qty:
Qty:
Qty:
Qty:
Part #:1128-2503-10-10
Qty:
Part #:1128-12 C5OX-S
Qty:
Qty:
Qty:
Part #:1128-20 F65OX-S
- Performance Characteristics
Connection Type
37° Flare
Industry Standards
SAE J514
Maximum Dynamic Pressure (psi)
4000
Shape
Straight
Connection Style
Tube to SAE-ORB
Connection 1 Style
Female 37° Flare Swivel
Connection 1 Tube O.D. (inch)
1 1/4
Connection 1 Tube O.D. (mm)
28, 30, 32
Connection 2 Style
Male SAE-ORB
Connection 2 Tube O.D. (inch)
na
Connection 2 Tube O.D. (mm)
na
Connection 2 Thread Size (inch)
1 5/8-12
Connection 2 Thread Size (mm)
na
Connection 3 Style
na
Connection 3 Tube O.D. (inch)
na
Connection 3 Tube O.D. (mm)
na
Connection 3 Thread Size (inch)
na
Connection 3 Thread Size (mm)
na
Connection 4 Style
na
Connection 4 Tube O.D. (inch)
na
Connection 4 Tube O.D. (mm)
na
O-Ring Material
90 Durometer Nitrile
Body Material
Steel, Chromium-6 Free
$
49.35
Qty:
Part #:1128-PH 8F5OX-S
-
Parker's 37° Flare JIC tube fittings and adapters, Triple-Lok®, meet the requirements of both SAE J514 and ISO 8434-2 and offer the industry's broadest offering of port ends. The design has a small metal to metal seal area which results in a compact design, low assembly torque, high temperature and high pressure capability.
Markets
&bull Construction
&bull Military Ground Systems
&bull Aerial Lift
&bull Agriculture
&bull Material Handling
&bull Military Marine
&bull Engine Transmission
Features/Benefits
&bull Easily adaptable to inch tube, metric tube and hose giving it worldwide acceptance.
&bull Vast selection of port end options, including SAE Straight Thread O-ring Boss (ORB), NPTF, BSPP-ED, BSPP-O-ring Retaining Ring (ORR), BSPP, BSPT, ISO 6149, Metric-O-ring Retaining Ring (ORR), and Metric-ED
&bull Parker's Robust Port Stud on adjustable ports is manufactured with a longer locknut virtually eliminating washer damage and potential leaks, as well as making assembly mistake-proof.
&bull Steel fittings substantially exceeded the SAE corrosion requirements of 72 hours without red rust, lasting up to 1,000 as found by an independent test facility.
&bull Stainless Steel nuts have a coating to prevent galling.
&bull Available in steel, stainless steel, and brass in sizes 1/8&rdquo - 2 ½&rdquo with working pressures up to 7500 psi.
Applications
&bull Hydraulic fluid and gas handling connections
Print Product Overview
s.
$
1.98
Qty:
Part #:1267-625-100-1-1-8-8
- Additional InformationFactory Mutual and Canadian Standards Association approvedCE compliant to suppress RFI, EMI and ESDNSI/ISA-12.27.01 approved single sealNOSHOK 625 and 626 Series transmitters are Factory Mutual and Canadian Standards Association approved for use in hazardous location applications as followsIntrinsically Safe, entity approval for Class I, II and III, Division 1, Groups A, B, C, D, E, F and G and Class I, Zone 0 Aex ia IICDust Ignition-proof for Class II and III, Division 2, Groups F and GNon-incendive for Class I, Division 2, Groups A, B, C and D.CE compliant with pressure equipment directive 2014/68/EU. ANSI/ISA-12.27.01, Approved single seal.Ideal for applications including chemical processing, gas pressure measurement, oil field & offshore, mining, vapory recovery systems, well head measurementLimitations Which Apply AreThese units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation.In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice.
Qty:
Part #:1267-625-1000-1-1-8-3
- Additional InformationFactory Mutual and Canadian Standards Association approvedCE compliant to suppress RFI, EMI and ESDNSI/ISA-12.27.01 approved single sealNOSHOK 625 and 626 Series transmitters are Factory Mutual and Canadian Standards Association approved for use in hazardous location applications as followsIntrinsically Safe, entity approval for Class I, II and III, Division 1, Groups A, B, C, D, E, F and G and Class I, Zone 0 Aex ia IICDust Ignition-proof for Class II and III, Division 2, Groups F and GNon-incendive for Class I, Division 2, Groups A, B, C and D.CE compliant with pressure equipment directive 2014/68/EU. ANSI/ISA-12.27.01, Approved single seal.Ideal for applications including chemical processing, gas pressure measurement, oil field & offshore, mining, vapory recovery systems, well head measurementLimitations Which Apply AreThese units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation.In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice.
Qty:
Part #:1267-625-1000-1-1-8-8
- Additional InformationFactory Mutual and Canadian Standards Association approvedCE compliant to suppress RFI, EMI and ESDNSI/ISA-12.27.01 approved single sealNOSHOK 625 and 626 Series transmitters are Factory Mutual and Canadian Standards Association approved for use in hazardous location applications as followsIntrinsically Safe, entity approval for Class I, II and III, Division 1, Groups A, B, C, D, E, F and G and Class I, Zone 0 Aex ia IICDust Ignition-proof for Class II and III, Division 2, Groups F and GNon-incendive for Class I, Division 2, Groups A, B, C and D.CE compliant with pressure equipment directive 2014/68/EU. ANSI/ISA-12.27.01, Approved single seal.Ideal for applications including chemical processing, gas pressure measurement, oil field & offshore, mining, vapory recovery systems, well head measurementLimitations Which Apply AreThese units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation.In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice.
Qty:
Part #:1267-625-10000-1-1-8-8
- Additional InformationFactory Mutual and Canadian Standards Association approvedCE compliant to suppress RFI, EMI and ESDNSI/ISA-12.27.01 approved single sealNOSHOK 625 and 626 Series transmitters are Factory Mutual and Canadian Standards Association approved for use in hazardous location applications as followsIntrinsically Safe, entity approval for Class I, II and III, Division 1, Groups A, B, C, D, E, F and G and Class I, Zone 0 Aex ia IICDust Ignition-proof for Class II and III, Division 2, Groups F and GNon-incendive for Class I, Division 2, Groups A, B, C and D.CE compliant with pressure equipment directive 2014/68/EU. ANSI/ISA-12.27.01, Approved single seal.Ideal for applications including chemical processing, gas pressure measurement, oil field & offshore, mining, vapory recovery systems, well head measurementLimitations Which Apply AreThese units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation.In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice.
Qty:
Part #:1267-625-12OZ/IN2-1-1-8-8
- Additional InformationFactory Mutual and Canadian Standards Association approvedCE compliant to suppress RFI, EMI and ESDNSI/ISA-12.27.01 approved single sealNOSHOK 625 and 626 Series transmitters are Factory Mutual and Canadian Standards Association approved for use in hazardous location applications as followsIntrinsically Safe, entity approval for Class I, II and III, Division 1, Groups A, B, C, D, E, F and G and Class I, Zone 0 Aex ia IICDust Ignition-proof for Class II and III, Division 2, Groups F and GNon-incendive for Class I, Division 2, Groups A, B, C and D.CE compliant with pressure equipment directive 2014/68/EU. ANSI/ISA-12.27.01, Approved single seal.Ideal for applications including chemical processing, gas pressure measurement, oil field & offshore, mining, vapory recovery systems, well head measurementLimitations Which Apply AreThese units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation.In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice.
Qty:
Part #:1267-625-15-1-1-8-14
- Additional InformationFactory Mutual and Canadian Standards Association approvedCE compliant to suppress RFI, EMI and ESDNSI/ISA-12.27.01 approved single sealNOSHOK 625 and 626 Series transmitters are Factory Mutual and Canadian Standards Association approved for use in hazardous location applications as followsIntrinsically Safe, entity approval for Class I, II and III, Division 1, Groups A, B, C, D, E, F and G and Class I, Zone 0 Aex ia IICDust Ignition-proof for Class II and III, Division 2, Groups F and GNon-incendive for Class I, Division 2, Groups A, B, C and D.CE compliant with pressure equipment directive 2014/68/EU. ANSI/ISA-12.27.01, Approved single seal.Ideal for applications including chemical processing, gas pressure measurement, oil field & offshore, mining, vapory recovery systems, well head measurementLimitations Which Apply AreThese units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation.In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice.
Qty:
Part #:1267-625-15-1-1-8-8
- Additional InformationFactory Mutual and Canadian Standards Association approvedCE compliant to suppress RFI, EMI and ESDNSI/ISA-12.27.01 approved single sealNOSHOK 625 and 626 Series transmitters are Factory Mutual and Canadian Standards Association approved for use in hazardous location applications as followsIntrinsically Safe, entity approval for Class I, II and III, Division 1, Groups A, B, C, D, E, F and G and Class I, Zone 0 Aex ia IICDust Ignition-proof for Class II and III, Division 2, Groups F and GNon-incendive for Class I, Division 2, Groups A, B, C and D.CE compliant with pressure equipment directive 2014/68/EU. ANSI/ISA-12.27.01, Approved single seal.Ideal for applications including chemical processing, gas pressure measurement, oil field & offshore, mining, vapory recovery systems, well head measurementLimitations Which Apply AreThese units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation.In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice.
Qty:
Part #:1267-625-15-2-1-8-8
- Additional InformationFactory Mutual and Canadian Standards Association approvedCE compliant to suppress RFI, EMI and ESDNSI/ISA-12.27.01 approved single sealNOSHOK 625 and 626 Series transmitters are Factory Mutual and Canadian Standards Association approved for use in hazardous location applications as followsIntrinsically Safe, entity approval for Class I, II and III, Division 1, Groups A, B, C, D, E, F and G and Class I, Zone 0 Aex ia IICDust Ignition-proof for Class II and III, Division 2, Groups F and GNon-incendive for Class I, Division 2, Groups A, B, C and D.CE compliant with pressure equipment directive 2014/68/EU. ANSI/ISA-12.27.01, Approved single seal.Ideal for applications including chemical processing, gas pressure measurement, oil field & offshore, mining, vapory recovery systems, well head measurementLimitations Which Apply AreThese units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation.In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice.
Qty:
Part #:1267-625-150-1-1-8-1
- Additional InformationFactory Mutual and Canadian Standards Association approvedCE compliant to suppress RFI, EMI and ESDNSI/ISA-12.27.01 approved single sealNOSHOK 625 and 626 Series transmitters are Factory Mutual and Canadian Standards Association approved for use in hazardous location applications as followsIntrinsically Safe, entity approval for Class I, II and III, Division 1, Groups A, B, C, D, E, F and G and Class I, Zone 0 Aex ia IICDust Ignition-proof for Class II and III, Division 2, Groups F and GNon-incendive for Class I, Division 2, Groups A, B, C and D.CE compliant with pressure equipment directive 2014/68/EU. ANSI/ISA-12.27.01, Approved single seal.Ideal for applications including chemical processing, gas pressure measurement, oil field & offshore, mining, vapory recovery systems, well head measurementLimitations Which Apply AreThese units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation.In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice.
Qty:
Part #:1267-625-150-1-1-8-8
- Additional InformationFactory Mutual and Canadian Standards Association approvedCE compliant to suppress RFI, EMI and ESDNSI/ISA-12.27.01 approved single sealNOSHOK 625 and 626 Series transmitters are Factory Mutual and Canadian Standards Association approved for use in hazardous location applications as followsIntrinsically Safe, entity approval for Class I, II and III, Division 1, Groups A, B, C, D, E, F and G and Class I, Zone 0 Aex ia IICDust Ignition-proof for Class II and III, Division 2, Groups F and GNon-incendive for Class I, Division 2, Groups A, B, C and D.CE compliant with pressure equipment directive 2014/68/EU. ANSI/ISA-12.27.01, Approved single seal.Ideal for applications including chemical processing, gas pressure measurement, oil field & offshore, mining, vapory recovery systems, well head measurementLimitations Which Apply AreThese units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation.In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice.
Qty:
Part #:1267-625-15000-1-1-8-8
- Additional InformationFactory Mutual and Canadian Standards Association approvedCE compliant to suppress RFI, EMI and ESDNSI/ISA-12.27.01 approved single sealNOSHOK 625 and 626 Series transmitters are Factory Mutual and Canadian Standards Association approved for use in hazardous location applications as followsIntrinsically Safe, entity approval for Class I, II and III, Division 1, Groups A, B, C, D, E, F and G and Class I, Zone 0 Aex ia IICDust Ignition-proof for Class II and III, Division 2, Groups F and GNon-incendive for Class I, Division 2, Groups A, B, C and D.CE compliant with pressure equipment directive 2014/68/EU. ANSI/ISA-12.27.01, Approved single seal.Ideal for applications including chemical processing, gas pressure measurement, oil field & offshore, mining, vapory recovery systems, well head measurementLimitations Which Apply AreThese units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation.In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice.
Qty:
Displaying: 1 - 24 of 52 Matching Items