Aluminum
1in
View:
Active Filters :
- Size: 1in
- Material: Aluminum Ductile Iron Manila
$
5.48
Qty:
Part #:521322
- Technical Specifications
Color Blue
Length (ft) 20
Pipe O.D. (mm) 25
Length (m) 6
Pipe O.D. (inch) 1
Pipe Outside Diameter 1 inch, 25 mm
Length 20 ft, 6 m
Color Blue
Maximum Operating Pressure 232 psi, 15.9 bar
Minimum Operating Temperature -4 °F, -20 °C
Maximum Operating Temperature +115 °F, +46.1 °C
Weight 4.24 lb, 1.92 kg
Vacuum Pressure Rating 29.6 Inch-Hg
Materials of Construction Powder Coated Aluminum
Application Compressed Air, Vacuum, Industrial/Inert Gases
Specifications Met EN 755.2, EN 755.8, EN 573.3, ISO 9001, ASME B31.1 - 31.9, ISO 8573 (Air Quality), TUV Certification, CE Conformity, QUALICOAT
$
14.95
Qty:
$
51.23
Qty:
Part #:301980
- Appleton Form 85 Unilets Conduit Outlet Bodies Covers and Gaskets are used to connect and change direction of conduit runs. In addition to making bends in a conduit system they allow connections for branch runs. These conduit bodies serve as pulling fittings and permit access to conductors for splicing and maintenance.
$
20.45
Qty:
$
20.19
Qty:
Part #:303015
- Appleton UNY UNF and UNL explosionproof and dust-ignitionproof unions are used for joining conduit and connecting conduit to enclosures. They facilitate modifications and permit the removal of enclosures without turning or removing conduit. They are also available as expansion unions which compensate for the expansion and contraction of conduit.
$
49.22
Qty:
Part #:501-D25913
- DS Series In-Line Condensate SeparatorsDuctile Iron Drain SeparatorCondensate in steam and air piping reduces thermal efficiency, causes water hammer, corrodes equipment such as valves and pipes, and causes other problems.
In-line (drain) separators DS-1, DS-2, DS-3, and DS-4 separate condensate efficiently by using the centrifugal force of steam or air created by introducing it into a specifically shaped path. Because of the simple structure of the drain separators, pressure loss is minimized, enabling clean, dry steam or air to be fed to equipment.
When steam or air flow enters the drain separator, centrifugal force is generated in the fluid because of the devices internal structural design. The fluid drains along the wall because of the difference in specific gravity with steam or air, eventually striking the baffle. The baffle guides the fluid to the drain outlet and to the trap, which drains it. As a result, small dirt particles and condensate are separated and removed from the system through the bottom drain.
• Cyclone structure maximizes liquid separation efficiency
• Pressure loss is extremely low
• No moving parts means no breakdowns
Qty:
Displaying: 1 - 13 of 13 Matching Items