Stainless Steel
Armstrong International


Displaying: 1 - 3 of 3 Matching Items
3 Items
View:
Active Filters :
Part #:501-C5738

Inverted Bucket Steam TrapsEnergy efficient because it's so reliable The inverted bucket is the most reliable steam trap operating principle known. The heart of its simple design is a unique leverage system that multiplies the force provided by the bucket to open the valve against pressure. Since the bucket is open at the bottom, it resists damage from water hammer, and wear points are heavily reinforced for long life. The inverted bucket has only two moving parts-the valve lever assembly and the bucket. That means no fixed points, no complicated linkage. Nothing to stick, bind or clog. Conserves energy even in the presence of wear Armstrong inverted bucket steam traps open and close based on the difference in density between condensate and steam-the inverted bucket principle. They open and close gently, minimizing wear. This simple fact means that inverted buckets are subject to less wear than some other types of traps. In fact, as an Armstrong inverted bucket trap wears, its tight seal actually improves. The valve and seat of the Armstrong trap provide essentially line contact-resulting in a tight seal because the entire closing force is concentrated on one narrow seating ring. An Armstrong inverted bucket steam trap continues to operate efficiently with use. Gradual wear slightly increases the diameter of the seat and alters the shape and diameter of the valve. But, as this occurs, a tight seal is still preserved-the ball merely seats itself more deeply. Corrosion-resistant parts The stainless steel valve and seat of the Armstrong inverted bucket steam trap are individually ground and lapped together in matched sets. All other working parts are wear- and corrosion-resistant stainless steel. Venting of air and CO2 The Armstrong inverted bucket provides continuous automatic air and CO2 venting with no cooling lag or threat of air binding. Operation against back pressure The Armstrong inverted bucket has excellent performance against back pressure. It has no adverse effect on inverted bucket operation other than to reduce its capacity by the low differential. The bucket simply requires less force to pull the valve open and cycle the trap. Freedom from dirt problems Armstrong designed its inverted bucket to be virtually free of dirt problems. The valve and seat are at the top of the trap, far away from the larger particles of dirt, which fall to the bottom. Here, the up-and-down action of the bucket pulverizes them. Since the valve of an inverted bucket is either fully closed or open, dirt particles pass freely. And the swift flow of condensate from under the bucket's edge creates a unique self-scrubbing action that sweeps dirt out of the trap.
$10,164.00 MSRP $ 9,027.26
Part #:501-D4802

TVS 4000F Series Stainless Steel Trap Valve Station Stainless Steel A complete package featuring two piston-style isolation valves, test valve and integral stainless steel strainer with blowdown valve. You'll realize all the benefits of a piston valve integrated into the same space-saving package.br Features &#8226 Reduced costs. TVS saves by eliminating potential leak points and reducing installation and maintenance time. &#8226 Multiple functions. TVS has test and strainer blowdown valves. When installed with Armstrong Model 2011 and 2022 steam traps, it will also accommodate the Armstrong pop drain, and SteamEyeremote steam trap monitoring and testing devices. &#8226 Reduced design time. Permits combining products with exact face-to-face dimensions. &#8226 Three-year guarantee. The TVS is guaranteed for three years. &#8226 Easy, in-line repairability with maximum safety. TVS allows isolation at point of service with upstream/downstream depressurization. &#8226 Installation versatility. The TVS is adaptable to any manufacturers two-bolt steam trap and piping configuration. &#8226 Simplified trap testing. You get enhanced capability to check trap operation and a built-in method to block and bleed traps. &#8226 Integral Flanges. The body and connections are of one piece construction, free of welds and other potential leak paths.
$2,786.00 MSRP $ 2,120.93
Part #:501-D4803

TVS 4000F Series Stainless Steel Trap Valve Station Stainless Steel A complete package featuring two piston-style isolation valves, test valve and integral stainless steel strainer with blowdown valve. You'll realize all the benefits of a piston valve integrated into the same space-saving package.br Features &#8226 Reduced costs. TVS saves by eliminating potential leak points and reducing installation and maintenance time. &#8226 Multiple functions. TVS has test and strainer blowdown valves. When installed with Armstrong Model 2011 and 2022 steam traps, it will also accommodate the Armstrong pop drain, and SteamEyeremote steam trap monitoring and testing devices. &#8226 Reduced design time. Permits combining products with exact face-to-face dimensions. &#8226 Three-year guarantee. The TVS is guaranteed for three years. &#8226 Easy, in-line repairability with maximum safety. TVS allows isolation at point of service with upstream/downstream depressurization. &#8226 Installation versatility. The TVS is adaptable to any manufacturers two-bolt steam trap and piping configuration. &#8226 Simplified trap testing. You get enhanced capability to check trap operation and a built-in method to block and bleed traps. &#8226 Integral Flanges. The body and connections are of one piece construction, free of welds and other potential leak paths.
$2,786.00 MSRP $ 2,120.93
 
Displaying: 1 - 3 of 3 Matching Items