Bussmann Division
Armstrong International
View:
Active Filters :
closeout
$5.93 MSRP
$
4.93
Qty:
closeout
$14.79 MSRP
$
12.31
Qty:
closeout
$19.41 MSRP
$
16.16
Qty:
closeout
$10.28 MSRP
$
8.56
Qty:
Part #:303034
- Catalog Number LPN-RK_SP (250V), LPS-RK_SP (600V) Dimensions See data sheets Volts - LPN-RK:
- 250Vac (up to 600A), 125Vdc (up to 60A), 250Vdc (70 to 600A) - LPS-RK
Qty:
closeout
$29.48 MSRP
$
23.87
Qty:
closeout
$103.83 MSRP
$
100.51
Qty:
closeout
$
197.18
Qty:
closeout
$129.48 MSRP
$
107.81
Qty:
closeout
$25.94 MSRP
$
21.60
Qty:
Part #:600417
- Features&bull High flow performance featuringrugged design for the mostdemanding applications&bull Ideal for those installations calling forconstant pressure with wide variationin flow&bull Diaphragm operated design withbalanced poppet design for quickand accurate regulation&bull Secondary aspiration plus balancedpoppet provides quick responseand accurate pressure regulation&bull Heavy duty tee handle adjustment&bull Reverse flow version available&bull Panel mount version available&bull High flow 1/4" &ndash 100 SCFM
Qty:
Part #:600441
- Features&bull Adapted for control by a remote ordistant small pilot regulator. Ideal formaximum capacity requirements inapplications where units are notreadily accessible&bull High flow performance featuringrugged design for the mostdemanding applications&bull Ideal for those installations calling forconstant pressure with wide variationin flow&bull Piston operated design with balancedpoppet and dual constant bleed forquick and accurate regulation&bull High flow 2" & 2-1/2" &ndash 1800 SCFM
Qty:
Qty:
Qty:
Part #:701257
- The most reliable steam trap known&mdashthe inverted bucket&mdashprovides efficientcondensate drainage of virtually all types of steam-using equipment. Putthe inverted bucket to work in a tough cast iron package, and you have thebest of both worlds. Because they operate efficiently for longer periods oftime, Armstrong cast iron inverted buckets add solid energy savings to lowerreplacement/labor costs. All Armstrong cast iron inverted bucket steam trapsare repairable for even bigger maintenance savings.
A unique leverage system multiplies the force provided by the bucket to openthe valve against system pressure. The mechanism is free-floating, and hasno fixed pivots to create wear or friction.
Because the mechanism is located at the top of the trap, no dirt can collecton the orifice. Small particles of dirt are held in suspension until dischargedby the full differential purging action when the bucket sinks, pulling the valveoff the seat.
The discharge orifice is surrounded by a water seal, preventing live steamloss. Automatic air venting is provided by a small vent hole in the bucket, whichprovides continuous automatic air and CO2 venting at steam temperature.Inverted bucket traps drain continuously, although discharging intermittently,allowing no condensate backup. They are also resistant to water hammer.
Qty:
Part #:701262
- The most reliable steam trap known&mdashthe inverted bucket&mdashprovides efficientcondensate drainage of virtually all types of steam-using equipment. Putthe inverted bucket to work in a tough cast iron package, and you have thebest of both worlds. Because they operate efficiently for longer periods oftime, Armstrong cast iron inverted buckets add solid energy savings to lowerreplacement/labor costs. All Armstrong cast iron inverted bucket steam trapsare repairable for even bigger maintenance savings.
A unique leverage system multiplies the force provided by the bucket to openthe valve against system pressure. The mechanism is free-floating, and hasno fixed pivots to create wear or friction.
Because the mechanism is located at the top of the trap, no dirt can collecton the orifice. Small particles of dirt are held in suspension until dischargedby the full differential purging action when the bucket sinks, pulling the valveoff the seat.
The discharge orifice is surrounded by a water seal, preventing live steamloss. Automatic air venting is provided by a small vent hole in the bucket, whichprovides continuous automatic air and CO2 venting at steam temperature.Inverted bucket traps drain continuously, although discharging intermittently,allowing no condensate backup. They are also resistant to water hammer.
Qty:
Part #:706405
-
Y-Type Cast Iron Strainers
250 lb Screwed 1/2"-3" Class 125 Flanged 2"-6" Class 250 Flanged 2"-6"
Screen chambers won't leak or crush
Both ends of the chambers are precisely machined. This means perfectly round and smooth seating surfaces, as well as a fixed chamber length. Since the screen seats snugly on the machined surface, no particle bigger than the screen opening can escape around the end of the screen.
Screwed retainers easy in, easy out
Straight threads mean it takes less torque to achieve a tight seal with proper gasket compression. Less torque is also required to remove the retainer. For you, that means less danger of "freezing in" than with hard-to-break tapered pipe threads.
Off-center blowdown connections for better dirt removal
Off-center drains on 2-1/2" and 3" strainers allow you to remove liquid and dirt nearly completely when blowing down the strainer. Also, less liquid will spill when the screen retainer is removed.
Many screen choices
Many screen materials, meshes and perforations are available.
Qty:
Part #:710287
- The most reliable steam trap known&mdashthe inverted bucket&mdashprovides efficientcondensate drainage of virtually all types of steam-using equipment. Putthe inverted bucket to work in a tough cast iron package, and you have thebest of both worlds. Because they operate efficiently for longer periods oftime, Armstrong cast iron inverted buckets add solid energy savings to lowerreplacement/labor costs. All Armstrong cast iron inverted bucket steam trapsare repairable for even bigger maintenance savings.
A unique leverage system multiplies the force provided by the bucket to openthe valve against system pressure. The mechanism is free-floating, and hasno fixed pivots to create wear or friction.
Because the mechanism is located at the top of the trap, no dirt can collecton the orifice. Small particles of dirt are held in suspension until dischargedby the full differential purging action when the bucket sinks, pulling the valveoff the seat.
The discharge orifice is surrounded by a water seal, preventing live steamloss. Automatic air venting is provided by a small vent hole in the bucket, whichprovides continuous automatic air and CO2 venting at steam temperature.Inverted bucket traps drain continuously, although discharging intermittently,allowing no condensate backup. They are also resistant to water hammer.
Qty:
Part #:713370
- Y-Type Cast Iron Strainers
250 lb Screwed 1/2"-3" Class 125 Flanged 2"-6" Class 250 Flanged 2"-6"
Screen chambers won't leak or crush
Both ends of the chambers are precisely machined. This means perfectly round and smooth seating surfaces, as well as a fixed chamber length. Since the screen seats snugly on the machined surface, no particle bigger than the screen opening can escape around the end of the screen.
Screwed retainers easy in, easy out
Straight threads mean it takes less torque to achieve a tight seal with proper gasket compression. Less torque is also required to remove the retainer. For you, that means less danger of "freezing in" than with hard-to-break tapered pipe threads.
Off-center blowdown connections for better dirt removal
Off-center drains on 2-1/2" and 3" strainers allow you to remove liquid and dirt nearly completely when blowing down the strainer. Also, less liquid will spill when the screen retainer is removed.
Many screen choices
Many screen materials, meshes and perforations are available
Qty:
Part #:602037
- Watts FRLs Regulator Diaphragm Relieving Kit & Valve Assembly Attributes
Weight
0.15 lb
Used on
R119-02, R119-03
$
39.98
Qty:
Part #:605114
- Watts FRLs Regulator Diaphragm Relieving Kit & Valve Assembly Attributes
Weight
0.165 lb
Used on
R119-04
$
49.24
Qty:
Part #:600411
- Country of Origin US:
Qty:
Part #:706642
- Steam Trap ConnectorsBesides 2000 Series stainless steel inverted bucket traps, the standard 360° connector or IS-2 connector with integral strainer can also be used on many Armstrong thermostatic, disc, bimetallic, and float and thermostatic traps. Any manufacturer&rsquos two-bolt steam traps can use Armstrong connectors. IS-2 Stainless Steel Connector with Integral Strainer &bull A full line stainless steel strainer in the connector eliminates leak points and reduces installation time &bull A strainer that is not discarded when the trap is replaced &bull Easy strainer screen replacement &bull Optional blowdown valve &bull Accommodates Armstrong&rsquos inverted bucket, disc, thermostatic, thermostatic wafer, bimetallic, and float and thermostatic traps. Any manufacturer&rsquos 2-bolt steam trap can also be applied to Armstrong&rsquos S-2 connector. Standard 360° Stainless Steel Connector &bull A compact, lightweight assembly &bull Standardization, reducing inventory &bull A compact design, simplifying piping &bull Accommodates Armstrong&rsquos inverted bucket, disc, thermostatic, thermostatic wafer and bimetallic steam traps. Any manufacturer&rsquos 2-bolt steam trap can also be applied to Armstrong&rsquos standard connector.
Qty:
Part #:706685
- Steam Trap ConnectorsBesides 2000 Series stainless steel inverted bucket traps, the standard 360° connector or IS-2 connector with integral strainer can also be used on many Armstrong thermostatic, disc, bimetallic, and float and thermostatic traps. Any manufacturer&rsquos two-bolt steam traps can use Armstrong connectors. IS-2 Stainless Steel Connector with Integral Strainer &bull A full line stainless steel strainer in the connector eliminates leak points and reduces installation time &bull A strainer that is not discarded when the trap is replaced &bull Easy strainer screen replacement &bull Optional blowdown valve &bull Accommodates Armstrong&rsquos inverted bucket, disc, thermostatic, thermostatic wafer, bimetallic, and float and thermostatic traps. Any manufacturer&rsquos 2-bolt steam trap can also be applied to Armstrong&rsquos S-2 connector. Standard 360° Stainless Steel Connector &bull A compact, lightweight assembly &bull Standardization, reducing inventory &bull A compact design, simplifying piping &bull Accommodates Armstrong&rsquos inverted bucket, disc, thermostatic, thermostatic wafer and bimetallic steam traps. Any manufacturer&rsquos 2-bolt steam trap can also be applied to Armstrong&rsquos standard connector.
Qty:
Displaying: 25 - 48 of 2,063 Matching Items