Cast Steel
Cast


Displaying: 1 - 24 of 146 Matching Items
146 Items
View:
Active Filters :
Part #:304966
Extremely durable for hard-use institutional applications. Spring-loaded covers close automatically when plugs are removed. Die-cast copper-free aluminum construction. Stainless steel springs. Screws and spring covers are chrome-plated brass. Baked-on lacquer finish. Heavy rubber gaskets provide positive seal. All covers below are for 4 screw mounting only. Comply with 2005 NEC Section 406.8(A) and 406.8(B)(2).
$ 12.35
Qty:
add to cart
$ 41.50
Qty:
add to cart
Part #:303701
One Gang Heavy Cast Aluminum Cover Duplex Receptacle Horizontal, Gray Extremely durable for hard-use institutional applications. Spring-loaded covers close automatically when plugs are removed. Die-cast copper-free aluminum construction. Stainless steel springs. Screws and spring covers are chrome-plated brass. Baked-on lacquer finish. Heavy rubber gaskets provide positive seal. All covers below are for 4 screw mounting only. Comply with 2005 NEC Section 406.8(A) and 406.8(B)(2). CSA File Number 16807
$71.48 MSRP $ 45.62
Qty:
add to cart
$ 21.17
Qty:
add to cart
$ 33.00
Qty:
add to cart
closeout
Part #:512353
CLOSEOUTS Only 1 Left!
$12.62 MSRP $ 8.09
Qty:
add to cart
Part #:300310
Single Gang Cast While-In-Use Cover, Gray Compliant with National Electric Code (NEC) Section 406.8(B)(1) for wet locations. UL listed for ''Extra-Duty'' applications. Heavy cast aluminum construction. Corner hinge allows for vertical or horizontal mounting. Device inserts allow for multiple device types. Install without removing electrical device thanks to keyed mounting holes. Cord flap gaskets inhibit water splash and insects, all gaskets are factory installed. Accepts padlocks.
$31.98 MSRP $ 23.81
Qty:
add to cart
$423.00 MSRP $ 274.95
Qty:
add to cart
$550.80 MSRP $ 358.02
Qty:
add to cart
$676.80 MSRP $ 439.92
Qty:
add to cart
$909.00 MSRP $ 590.85
Qty:
add to cart
$1,045.80 MSRP $ 679.77
Qty:
add to cart
$125.00 MSRP $ 81.25
Qty:
add to cart
$143.14 MSRP $ 93.04
Qty:
add to cart
$193.54 MSRP $ 125.80
Qty:
add to cart
Part #:302593
One Gang Heavy Cast Aluminum Cover Decorator/GFCI Horizontal, Gray Extremely durable for hard-use institutional applications. Spring-loaded covers close automatically when plugs are removed. Die-cast copper-free aluminum construction. Stainless steel springs. Screws and spring covers are chrome-plated brass. Baked-on lacquer finish. Heavy rubber gaskets provide positive seal. All covers below are for 4 screw mounting only. Comply with 2005 NEC Section 406.8(A) and 406.8(B)(2). CSA File Number 16807
$66.08 MSRP $ 42.17
Qty:
add to cart
Part #:302594
One Gang Heavy Cast Aluminum Cover Decorator/GFCI Vertical, Gray Extremely durable for hard-use institutional applications. Spring-loaded covers close automatically when plugs are removed. Die-cast copper-free aluminum construction. Stainless steel springs. Screws and spring covers are chrome-plated brass. Baked-on lacquer finish. Heavy rubber gaskets provide positive seal. All covers below are for 4 screw mounting only. Comply with 2005 NEC Section 406.8(A) and 406.8(B)(2). CSA File Number 16807
$61.11 MSRP $ 39.01
Qty:
add to cart
Part #:303252
Cast Weatherproof Two Gang Cover, Gray Broad line of two gang covers for switches, receptacles, GFCIs, and power outlets. Baked-on electrostatic, polyester, powder paint for superior scratch and corrosion resistance. Heavy-duty die-cast zinc. Stainless steel springs. All covers have 2 self-closing lids. Covers comply with 2005 NEC Section 406.8(A) and 406.8(B)(2).
$35.69 MSRP $ 22.78
Qty:
add to cart
Part #:303216
Cast Weatherproof Cover Single Pole Toggle Switch, Gray Broad line of single gang covers for switches and GFCIs. Baked-on electrostatic, polyester, powder paint for superior scratch and corrosion resistance. Heavy-duty die-cast zinc. Stainless steel springs. Covers comply with 2005 NEC Section 406.8(A) and 406.8(B)(2).
$15.78 MSRP $ 11.74
Qty:
add to cart
closeout
Part #:501964
CLOSEOUTS Only 3 Left!
$9.10 MSRP $ 7.28
Qty:
add to cart
Part #:501-D500388
Inverted Bucket Steam TrapsEnergy efficient because it's so reliable The inverted bucket is the most reliable steam trap operating principle known. The heart of its simple design is a unique leverage system that multiplies the force provided by the bucket to open the valve against pressure. Since the bucket is open at the bottom, it resists damage from water hammer, and wear points are heavily reinforced for long life. The inverted bucket has only two moving parts-the valve lever assembly and the bucket. That means no fixed points, no complicated linkage. Nothing to stick, bind or clog. Conserves energy even in the presence of wear Armstrong inverted bucket steam traps open and close based on the difference in density between condensate and steam-the inverted bucket principle. They open and close gently, minimizing wear. This simple fact means that inverted buckets are subject to less wear than some other types of traps. In fact, as an Armstrong inverted bucket trap wears, its tight seal actually improves. The valve and seat of the Armstrong trap provide essentially line contact-resulting in a tight seal because the entire closing force is concentrated on one narrow seating ring. An Armstrong inverted bucket steam trap continues to operate efficiently with use. Gradual wear slightly increases the diameter of the seat and alters the shape and diameter of the valve. But, as this occurs, a tight seal is still preserved-the ball merely seats itself more deeply. Corrosion-resistant parts The stainless steel valve and seat of the Armstrong inverted bucket steam trap are individually ground and lapped together in matched sets. All other working parts are wear- and corrosion-resistant stainless steel. Venting of air and CO2 The Armstrong inverted bucket provides continuous automatic air and CO2 venting with no cooling lag or threat of air binding. Operation against back pressure The Armstrong inverted bucket has excellent performance against back pressure. It has no adverse effect on inverted bucket operation other than to reduce its capacity by the low differential. The bucket simply requires less force to pull the valve open and cycle the trap. Freedom from dirt problems Armstrong designed its inverted bucket to be virtually free of dirt problems. The valve and seat are at the top of the trap, far away from the larger particles of dirt, which fall to the bottom. Here, the up-and-down action of the bucket pulverizes them. Since the valve of an inverted bucket is either fully closed or open, dirt particles pass freely. And the swift flow of condensate from under the bucket's edge creates a unique self-scrubbing action that sweeps dirt out of the trap.
$3,419.90 MSRP $ 2,603.50
Qty:
add to cart
Part #:501-D500525
Inverted Bucket Steam TrapsEnergy efficient because it's so reliable The inverted bucket is the most reliable steam trap operating principle known. The heart of its simple design is a unique leverage system that multiplies the force provided by the bucket to open the valve against pressure. Since the bucket is open at the bottom, it resists damage from water hammer, and wear points are heavily reinforced for long life. The inverted bucket has only two moving parts-the valve lever assembly and the bucket. That means no fixed points, no complicated linkage. Nothing to stick, bind or clog. Conserves energy even in the presence of wear Armstrong inverted bucket steam traps open and close based on the difference in density between condensate and steam-the inverted bucket principle. They open and close gently, minimizing wear. This simple fact means that inverted buckets are subject to less wear than some other types of traps. In fact, as an Armstrong inverted bucket trap wears, its tight seal actually improves. The valve and seat of the Armstrong trap provide essentially line contact-resulting in a tight seal because the entire closing force is concentrated on one narrow seating ring. An Armstrong inverted bucket steam trap continues to operate efficiently with use. Gradual wear slightly increases the diameter of the seat and alters the shape and diameter of the valve. But, as this occurs, a tight seal is still preserved-the ball merely seats itself more deeply. Corrosion-resistant parts The stainless steel valve and seat of the Armstrong inverted bucket steam trap are individually ground and lapped together in matched sets. All other working parts are wear- and corrosion-resistant stainless steel. Venting of air and CO2 The Armstrong inverted bucket provides continuous automatic air and CO2 venting with no cooling lag or threat of air binding. Operation against back pressure The Armstrong inverted bucket has excellent performance against back pressure. It has no adverse effect on inverted bucket operation other than to reduce its capacity by the low differential. The bucket simply requires less force to pull the valve open and cycle the trap. Freedom from dirt problems Armstrong designed its inverted bucket to be virtually free of dirt problems. The valve and seat are at the top of the trap, far away from the larger particles of dirt, which fall to the bottom. Here, the up-and-down action of the bucket pulverizes them. Since the valve of an inverted bucket is either fully closed or open, dirt particles pass freely. And the swift flow of condensate from under the bucket's edge creates a unique self-scrubbing action that sweeps dirt out of the trap.
$4,430.70 MSRP $ 3,372.90
Qty:
add to cart
Part #:501-D500543
Inverted Bucket Steam TrapsEnergy efficient because it's so reliable The inverted bucket is the most reliable steam trap operating principle known. The heart of its simple design is a unique leverage system that multiplies the force provided by the bucket to open the valve against pressure. Since the bucket is open at the bottom, it resists damage from water hammer, and wear points are heavily reinforced for long life. The inverted bucket has only two moving parts-the valve lever assembly and the bucket. That means no fixed points, no complicated linkage. Nothing to stick, bind or clog. Conserves energy even in the presence of wear Armstrong inverted bucket steam traps open and close based on the difference in density between condensate and steam-the inverted bucket principle. They open and close gently, minimizing wear. This simple fact means that inverted buckets are subject to less wear than some other types of traps. In fact, as an Armstrong inverted bucket trap wears, its tight seal actually improves. The valve and seat of the Armstrong trap provide essentially line contact-resulting in a tight seal because the entire closing force is concentrated on one narrow seating ring. An Armstrong inverted bucket steam trap continues to operate efficiently with use. Gradual wear slightly increases the diameter of the seat and alters the shape and diameter of the valve. But, as this occurs, a tight seal is still preserved-the ball merely seats itself more deeply. Corrosion-resistant parts The stainless steel valve and seat of the Armstrong inverted bucket steam trap are individually ground and lapped together in matched sets. All other working parts are wear- and corrosion-resistant stainless steel. Venting of air and CO2 The Armstrong inverted bucket provides continuous automatic air and CO2 venting with no cooling lag or threat of air binding. Operation against back pressure The Armstrong inverted bucket has excellent performance against back pressure. It has no adverse effect on inverted bucket operation other than to reduce its capacity by the low differential. The bucket simply requires less force to pull the valve open and cycle the trap. Freedom from dirt problems Armstrong designed its inverted bucket to be virtually free of dirt problems. The valve and seat are at the top of the trap, far away from the larger particles of dirt, which fall to the bottom. Here, the up-and-down action of the bucket pulverizes them. Since the valve of an inverted bucket is either fully closed or open, dirt particles pass freely. And the swift flow of condensate from under the bucket's edge creates a unique self-scrubbing action that sweeps dirt out of the trap.
$1,910.00 MSRP $ 1,454.00
Qty:
add to cart
Part #:501-D500556
Inverted Bucket Steam TrapsEnergy efficient because it's so reliable The inverted bucket is the most reliable steam trap operating principle known. The heart of its simple design is a unique leverage system that multiplies the force provided by the bucket to open the valve against pressure. Since the bucket is open at the bottom, it resists damage from water hammer, and wear points are heavily reinforced for long life. The inverted bucket has only two moving parts-the valve lever assembly and the bucket. That means no fixed points, no complicated linkage. Nothing to stick, bind or clog. Conserves energy even in the presence of wear Armstrong inverted bucket steam traps open and close based on the difference in density between condensate and steam-the inverted bucket principle. They open and close gently, minimizing wear. This simple fact means that inverted buckets are subject to less wear than some other types of traps. In fact, as an Armstrong inverted bucket trap wears, its tight seal actually improves. The valve and seat of the Armstrong trap provide essentially line contact-resulting in a tight seal because the entire closing force is concentrated on one narrow seating ring. An Armstrong inverted bucket steam trap continues to operate efficiently with use. Gradual wear slightly increases the diameter of the seat and alters the shape and diameter of the valve. But, as this occurs, a tight seal is still preserved-the ball merely seats itself more deeply. Corrosion-resistant parts The stainless steel valve and seat of the Armstrong inverted bucket steam trap are individually ground and lapped together in matched sets. All other working parts are wear- and corrosion-resistant stainless steel. Venting of air and CO2 The Armstrong inverted bucket provides continuous automatic air and CO2 venting with no cooling lag or threat of air binding. Operation against back pressure The Armstrong inverted bucket has excellent performance against back pressure. It has no adverse effect on inverted bucket operation other than to reduce its capacity by the low differential. The bucket simply requires less force to pull the valve open and cycle the trap. Freedom from dirt problems Armstrong designed its inverted bucket to be virtually free of dirt problems. The valve and seat are at the top of the trap, far away from the larger particles of dirt, which fall to the bottom. Here, the up-and-down action of the bucket pulverizes them. Since the valve of an inverted bucket is either fully closed or open, dirt particles pass freely. And the swift flow of condensate from under the bucket's edge creates a unique self-scrubbing action that sweeps dirt out of the trap.
$6,244.00 MSRP $ 4,753.40
Qty:
add to cart
 
Displaying: 1 - 24 of 146 Matching Items