Armstrong International
DeWalt
View:
Active Filters :
- Brand: DeWalt Armstrong International Trent Vogt
- Size: 1in
Qty:
Qty:
Qty:
Part #:706681
- Steam Trap ConnectorsBesides 2000 Series stainless steel inverted bucket traps, the standard 360° connector or IS-2 connector with integral strainer can also be used on many Armstrong thermostatic, disc, bimetallic, and float and thermostatic traps. Any manufacturer&rsquos two-bolt steam traps can use Armstrong connectors. IS-2 Stainless Steel Connector with Integral Strainer &bull A full line stainless steel strainer in the connector eliminates leak points and reduces installation time &bull A strainer that is not discarded when the trap is replaced &bull Easy strainer screen replacement &bull Optional blowdown valve &bull Accommodates Armstrong&rsquos inverted bucket, disc, thermostatic, thermostatic wafer, bimetallic, and float and thermostatic traps. Any manufacturer&rsquos 2-bolt steam trap can also be applied to Armstrong&rsquos S-2 connector. Standard 360° Stainless Steel Connector &bull A compact, lightweight assembly &bull Standardization, reducing inventory &bull A compact design, simplifying piping &bull Accommodates Armstrong&rsquos inverted bucket, disc, thermostatic, thermostatic wafer and bimetallic steam traps. Any manufacturer&rsquos 2-bolt steam trap can also be applied to Armstrong&rsquos standard connector.
Qty:
Qty:
Qty:
Qty:
Part #:713363
-
Y-Type Cast Iron Strainers
250 lb Screwed 1/2"-3" Class 125 Flanged 2"-6" Class 250 Flanged 2"-6"
Screen chambers won't leak or crush
Both ends of the chambers are precisely machined. This means perfectly round and smooth seating surfaces, as well as a fixed chamber length. Since the screen seats snugly on the machined surface, no particle bigger than the screen opening can escape around the end of the screen.
Screwed retainers easy in, easy out
Straight threads mean it takes less torque to achieve a tight seal with proper gasket compression. Less torque is also required to remove the retainer. For you, that means less danger of "freezing in" than with hard-to-break tapered pipe threads.
Off-center blowdown connections for better dirt removal
Off-center drains on 2-1/2" and 3" strainers allow you to remove liquid and dirt nearly completely when blowing down the strainer. Also, less liquid will spill when the screen retainer is removed.
Many screen choices
Many screen materials, meshes and perforations are available.
Qty:
Qty:
Part #:701262
- The most reliable steam trap known&mdashthe inverted bucket&mdashprovides efficientcondensate drainage of virtually all types of steam-using equipment. Putthe inverted bucket to work in a tough cast iron package, and you have thebest of both worlds. Because they operate efficiently for longer periods oftime, Armstrong cast iron inverted buckets add solid energy savings to lowerreplacement/labor costs. All Armstrong cast iron inverted bucket steam trapsare repairable for even bigger maintenance savings.
A unique leverage system multiplies the force provided by the bucket to openthe valve against system pressure. The mechanism is free-floating, and hasno fixed pivots to create wear or friction.
Because the mechanism is located at the top of the trap, no dirt can collecton the orifice. Small particles of dirt are held in suspension until dischargedby the full differential purging action when the bucket sinks, pulling the valveoff the seat.
The discharge orifice is surrounded by a water seal, preventing live steamloss. Automatic air venting is provided by a small vent hole in the bucket, whichprovides continuous automatic air and CO2 venting at steam temperature.Inverted bucket traps drain continuously, although discharging intermittently,allowing no condensate backup. They are also resistant to water hammer.
Qty:
Part #:706642
- Steam Trap ConnectorsBesides 2000 Series stainless steel inverted bucket traps, the standard 360° connector or IS-2 connector with integral strainer can also be used on many Armstrong thermostatic, disc, bimetallic, and float and thermostatic traps. Any manufacturer&rsquos two-bolt steam traps can use Armstrong connectors. IS-2 Stainless Steel Connector with Integral Strainer &bull A full line stainless steel strainer in the connector eliminates leak points and reduces installation time &bull A strainer that is not discarded when the trap is replaced &bull Easy strainer screen replacement &bull Optional blowdown valve &bull Accommodates Armstrong&rsquos inverted bucket, disc, thermostatic, thermostatic wafer, bimetallic, and float and thermostatic traps. Any manufacturer&rsquos 2-bolt steam trap can also be applied to Armstrong&rsquos S-2 connector. Standard 360° Stainless Steel Connector &bull A compact, lightweight assembly &bull Standardization, reducing inventory &bull A compact design, simplifying piping &bull Accommodates Armstrong&rsquos inverted bucket, disc, thermostatic, thermostatic wafer and bimetallic steam traps. Any manufacturer&rsquos 2-bolt steam trap can also be applied to Armstrong&rsquos standard connector.
Qty:
Qty:
Qty:
Qty:
Qty:
Qty:
Qty:
Qty:
Qty:
Qty:
Qty:
Part #:1130-55007
$
47.00
Qty:
Part #:501-B4908
- CD-40 and CD-60 Series Controlled Disc Steam TrapsFor pressures to 600 psig (41 barg)
Capacities to 2,850 lb/hr (1 295 kg/hr)
Armstrong CD-40 and CD-60 Series controlled disc traps contain a replaceable capsule, making it possible to renew a worn trap by simply replacing the capsule. A heating chamber in the shell ensures consistent operation. This steam jacket provides a relatively constant temperature in the control chamber regardless of ambient conditions. Cycling rate is controlled and does not increase when the trap is exposed to cold winds, rain or snow. CD-40 Series traps are also available with optional integral .045 perforated stainless steel strainer screens. CD-60 Series traps contain integral strainers with ratios of open area to inside area of pipe that equal or exceed those of most separate Y-type strainers.
Qty:
Displaying: 1 - 24 of 497 Matching Items