1A
Electrical Equipment
View:
Active Filters :
- Main Category: Electrical Equipment
- Amperage: 1A 20A/30A 35A 500mA
Part #:305126
- Advanced protection 600Vac, 1/4-30A, time-delay fuses Class CC current-limiting, time-delay fuses.
Qty:
Part #:305127
- Advanced protection 600Vac, 1/4-30A, time-delay fuses Class CC current-limiting, time-delay fuses.
Qty:
Part #:303395
- Thermoplastic Weatherproof Covers for Flanged Inlet/Outlet
Unbreakable glass-filled polycarbonate construction to withstand years of job site abuse and harsh environmental exposure.
Stainless steel mounting screws also resist corrosion.
Covers comply with 2005 NEC Section 406.8(A) and 406.8(B)(2).
Molded-in label area (2.8 sq. in.) for pre-printed or handwritten labels for identification of circuits, ratings and other application data.
WPG1 and WPG2 have lockable bullnose for OSHA locktag/tagout compliance.
Covers fit all competitive inlets and outlets.
Pre-attached gaskets for easy installation and tight seal to panel or weatherproof box -- with no misaligned or collapsed gaskets.
Tamper-proof hinge features permanent, locked-in pins for added security.
cULus ListingNumber 143222
Qty:
Part #:300531
- Catalog Number LPN-RK_SP (250V), LPS-RK_SP (600V) Dimensions See data sheets Volts - LPN-RK:
- 250Vac (up to 600A), 125Vdc (up to 60A), 250Vdc (70 to 600A) - LPS-RK
Qty:
Part #:300656
- Catalog Number FNA-(amp) Dimensions 13⁄32” x 1 1⁄2” (10.3 x 38.1mm) Volts - 250Vac (1⁄10-6A) - 125Vac (6 1/4-15A) - 32Vac (20-30A) Amps 1⁄10-30A IR See data sheet # 2029 for interrupting rating by circuit voltage and fuse amp rating Agency Information - CE - UL Listed 1/10 to 8/10A @ 125/250Vac, 1-15A @ 125Vac, Guide JDYX, File E19180 - CSA Certified 1/10 to 10A @ 125Vac, Class 1422-01, File 53787 Typical Applications - Power electronic circuits with high inrush currents and fuse openings must be quickly apparent - Inductive load circuits where pin indication of open fuse condition is desired Construction - Silver-plated pin for positive, electrical signal activation - 12 amp and more versions are dual-tube construction:
Qty:
Part #:300756
- Catalog Number LPN-RK_SP (250V), LPS-RK_SP (600V) Dimensions See data sheets Volts - LPN-RK:
- 250Vac (up to 600A), 125Vdc (up to 60A), 250Vdc (70 to 600A) - LPS-RK
Qty:
Part #:301092
- 13&frasl32 x 1-1/2 250Vac Fast-acting supplemental fuses Catalog symbol &ndash color code BAF - Green (250Vac max 1/4 to 30A) For superior protection, Bussmann recommends upgrading to Low-Peak&trade Class CC fuses.
Qty:
Part #:302083
- Features Separate overload and short-circuit elements provide time delay for sizing as close as 125% of motor FLA 2:
- 1 selective coordination amp ratio (within the Cooper Bussmann RK5 fuse family) prevents overcurrent events from opening upstream Fusetron fuses Insulated end caps for 225A-600A fuses reduces exposure to live parts and extends air gap to distance between blades of adjacent mounted fuses or to housing
Qty:
Part #:302121
- Advanced Protection Energy Efficient 600Vac/300Vdc, 1/10-600A, Dual Element, Time-Delay Fuses Energy efficient Class RK5 dual element, current-limiting, time-delay fuses with optional open fuse indication on select ratings (see data sheets). Time-delay &ndash 10 second (minimum) at 500% of rated current. Fusetron fuses are on average 23% more energy efficient than the next leading brand.
Qty:
Part #:302781
- Catalog Number LPN-RK_SP (250V), LPS-RK_SP (600V) Dimensions See data sheets Volts - LPN-RK:
- 250Vac (up to 600A), 125Vdc (up to 60A), 250Vdc (70 to 600A) - LPS-RK
Qty:
Part #:303631
- Catalog Number LPJ_SP-_ Dimensions See Data Sheets # 1006 (1-60A) & #1007 (70-600A) Volts - 600Vac - 300Vdc (does not apply to indicating versions) Amps 1-600A IR - 300kA Vac RMS Sym. - 100kA Vdc Agency Information - CE - UL Listed, Guide JDDZ, File E4273 - CSA Certified, Class J per CSA-22.2 NO. 248.8, Class 1422-02, File 53787 Typical Applications - Power Panelboards - Branch Circuit Breaker Panelboard Mains - Machinery Disconnects - Industrial Control:
Qty:
closeout
Part #:304771
- CLOSEOUTS Only 1 Left!
- Industrial Spec Grade Turnlok® Locking Devices Accessories
$
13.24
Qty:
Part #:306232
- Features Separate overload and short-circuit elements provide time delay for sizing as close as 125% of motor FLA 2:
- 1 selective coordination amp ratio (within the Cooper Bussmann RK5 fuse family) prevents overcurrent events from opening upstream Fusetron fuses Insulated end caps for 225A-600A fuses reduces exposure to live parts and extends air gap to distance between blades of adjacent mounted fuses or to housing
Qty:
Part #:306387
- 13&frasl32 x 1-1&frasl2 250Vac Time-delay supplemental fuses Catalog symbol / color code FNM - Green (250Vac maximum voltage)
Qty:
Part #:311767
- Basic Protection 250V (NON) and 600V (NOS), 1/8-600A General Purpose Fuses
Qty:
Qty:
Qty:
Qty:
Part #:194-FNQ-1
- Eaton Bussmann series FNQ fuse, Time-delay Midget fuse, Motor control transformers, circuits with in-rush currents, 1 A, Non-indicating, Ferrule end x ferrule end, 10 kAIC at 500 Vac, Nickel-plated bronze endcap, Standard, 500 V
Qty:
Displaying: 1 - 23 of 23 Matching Items