2.4in
Electrical Equipment
View:
Active Filters :
- Main Category: Electrical Equipment
- Length: 2.4in .56in 24.9in 7.88in
Part #:302130
- Advanced Protection Energy Efficient 600Vac/300Vdc, 1/10-600A, Dual Element, Time-Delay Fuses Energy efficient Class RK5 dual element, current-limiting, time-delay fuses with optional open fuse indication on select ratings (see data sheets). Time-delay &ndash 10 second (minimum) at 500% of rated current. Fusetron fuses are on average 23% more energy efficient than the next leading brand.
Qty:
Part #:311696
- Advanced Protection Energy Efficient 600Vac/300Vdc, 1/10-600A, Dual Element, Time-Delay Fuses Energy efficient Class RK5 dual element, current-limiting, time-delay fuses with optional open fuse indication on select ratings (see data sheets). Time-delay &ndash 10 second (minimum) at 500% of rated current. Fusetron fuses are on average 23% more energy efficient than the next leading brand.
Qty:
Part #:302084
- Features Separate overload and short-circuit elements provide time delay for sizing as close as 125% of motor FLA 2:
- 1 selective coordination amp ratio (within the Cooper Bussmann RK5 fuse family) prevents overcurrent events from opening upstream Fusetron fuses Insulated end caps for 225A-600A fuses reduces exposure to live parts and extends air gap to distance between blades of adjacent mounted fuses or to housing
Qty:
Part #:302093
- Features Separate overload and short-circuit elements provide time delay for sizing as close as 125% of motor FLA 2:
- 1 selective coordination amp ratio (within the Cooper Bussmann RK5 fuse family) prevents overcurrent events from opening upstream Fusetron fuses Insulated end caps for 225A-600A fuses reduces exposure to live parts and extends air gap to distance between blades of adjacent mounted fuses or to housing
Qty:
Part #:302101
- Features Separate overload and short-circuit elements provide time delay for sizing as close as 125% of motor FLA 2:
- 1 selective coordination amp ratio (within the Cooper Bussmann RK5 fuse family) prevents overcurrent events from opening upstream Fusetron fuses Insulated end caps for 225A-600A fuses reduces exposure to live parts and extends air gap to distance between blades of adjacent mounted fuses or to housing
Qty:
Part #:302796
- Catalog Number LPN-RK_SP (250V), LPS-RK_SP (600V) Dimensions See data sheets Volts - LPN-RK:
- 250Vac (up to 600A), 125Vdc (up to 60A), 250Vdc (70 to 600A) - LPS-RK
Qty:
Part #:302863
- Basic Protection 250V (NON) and 600V (NOS), 1/8-600A General Purpose Fuses
Qty:
Part #:303041
- Catalog Number LPN-RK_SP (250V), LPS-RK_SP (600V) Dimensions See data sheets Volts - LPN-RK:
- 250Vac (up to 600A), 125Vdc (up to 60A), 250Vdc (70 to 600A) - LPS-RK
Qty:
Part #:303761
- Advanced Protection Energy Efficient 600Vac/300Vdc, 1/10-600A, Dual Element, Time-Delay Fuses Energy efficient Class RK5 dual element, current-limiting, time-delay fuses with optional open fuse indication on select ratings (see data sheets). Time-delay &ndash 10 second (minimum) at 500% of rated current. Fusetron fuses are on average 23% more energy efficient than the next leading brand.
Qty:
Part #:305540
- Advanced Protection Energy Efficient 600Vac/300Vdc, 1/10-600A, Dual Element, Time-Delay Fuses Energy efficient Class RK5 dual element, current-limiting, time-delay fuses with optional open fuse indication on select ratings (see data sheets). Time-delay &ndash 10 second (minimum) at 500% of rated current. Fusetron fuses are on average 23% more energy efficient than the next leading brand.
Qty:
Part #:306503
- Features Separate overload and short-circuit elements provide time delay for sizing as close as 125% of motor FLA 2:
- 1 selective coordination amp ratio (within the Cooper Bussmann RK5 fuse family) prevents overcurrent events from opening upstream Fusetron fuses Insulated end caps for 225A-600A fuses reduces exposure to live parts and extends air gap to distance between blades of adjacent mounted fuses or to housing
Qty:
Part #:308115
- SPECIFICATIONS
Amperage Rating
20 A
Color
Yellow
Jacket Material
Thermoplastic
Length
5-1/4 in
Temperature Rating
-30 to 150 deg F
Type
2-Pole In-Line Manual Reset
Voltage Rating
125 VAC
$
58.19
Qty:
Part #:194-FRN-R-8/10
- Eaton Bussmann series FRN-R fuse, 0.8 A, Dual, Class RK5, Non-indicating, Ferrule end x ferrule end, 8 sec at 500%, 200 kAIC at 250 V20 kAIC at 125 Vdc, Standard, 250 V, 125 Vdc
Qty:
Displaying: 1 - 14 of 14 Matching Items