3"
Electrical Equipment
View:
Active Filters :
- Main Category: Electrical Equipment
- Alt. Length: 3" 1.5" 7.13" 2.085"
Part #:300407
- Catalog Number LPN-RK_SP (250V), LPS-RK_SP (600V) Dimensions See data sheets Volts - LPN-RK:
- 250Vac (up to 600A), 125Vdc (up to 60A), 250Vdc (70 to 600A) - LPS-RK
Qty:
Part #:300656
- Catalog Number FNA-(amp) Dimensions 13⁄32” x 1 1⁄2” (10.3 x 38.1mm) Volts - 250Vac (1⁄10-6A) - 125Vac (6 1/4-15A) - 32Vac (20-30A) Amps 1⁄10-30A IR See data sheet # 2029 for interrupting rating by circuit voltage and fuse amp rating Agency Information - CE - UL Listed 1/10 to 8/10A @ 125/250Vac, 1-15A @ 125Vac, Guide JDYX, File E19180 - CSA Certified 1/10 to 10A @ 125Vac, Class 1422-01, File 53787 Typical Applications - Power electronic circuits with high inrush currents and fuse openings must be quickly apparent - Inductive load circuits where pin indication of open fuse condition is desired Construction - Silver-plated pin for positive, electrical signal activation - 12 amp and more versions are dual-tube construction:
Qty:
Part #:301112
- 13&frasl32 x 1-1/2 250Vac Fast-acting supplemental fuses Catalog symbol &ndash color code BAF - Green (250Vac max 1/4 to 30A) For superior protection, Bussmann recommends upgrading to Low-Peak&trade Class CC fuses.
Qty:
Part #:301116
- 13&frasl32 x 1-1/2 250Vac Fast-acting supplemental fuses Catalog symbol &ndash color code BAF - Green (250Vac max 1/4 to 30A) For superior protection, Bussmann recommends upgrading to Low-Peak&trade Class CC fuses.
Qty:
Part #:301125
- 13&frasl32 x 1-1/2 250Vac Fast-acting supplemental fuses Catalog symbol &ndash color code BAF - Green (250Vac max 1/4 to 30A) For superior protection, Bussmann recommends upgrading to Low-Peak&trade Class CC fuses.
Qty:
Part #:301312
- 13&frasl32 x 1-1&frasl2 500Vac Time-delay supplemental fuses Catalog symbol / color code FNQ - Orange (500Vac maximum voltage)
Qty:
Part #:301386
- 13&frasl32 x 1-1&frasl2 500Vac Time-delay supplemental fuses Catalog symbol / color code FNQ - Orange (500Vac maximum voltage)
Qty:
Part #:301510
- 13&frasl32 x 1-1&frasl2 250Vac Time-delay supplemental fuses Catalog symbol / color code FNM - Green (250Vac maximum voltage)
Qty:
closeout
$16.88 MSRP
$
12.58
Part #:301613
- CLOSEOUTS Only 4 Left!
- 20A NEMA Plug L220 - Black Back, White Front Body
Interior components constructed of high-grade brass material for physical and electrical integrity.
High-impact thermoplastic housing withstands on-the-job abuse.
Ratings and NEMA configurations are clearly visible on flange face, for fast I.D. while in use.
Qty:
Part #:302090
- Features Separate overload and short-circuit elements provide time delay for sizing as close as 125% of motor FLA 2:
- 1 selective coordination amp ratio (within the Cooper Bussmann RK5 fuse family) prevents overcurrent events from opening upstream Fusetron fuses Insulated end caps for 225A-600A fuses reduces exposure to live parts and extends air gap to distance between blades of adjacent mounted fuses or to housing
Qty:
Part #:302091
- Features Separate overload and short-circuit elements provide time delay for sizing as close as 125% of motor FLA 2:
- 1 selective coordination amp ratio (within the Cooper Bussmann RK5 fuse family) prevents overcurrent events from opening upstream Fusetron fuses Insulated end caps for 225A-600A fuses reduces exposure to live parts and extends air gap to distance between blades of adjacent mounted fuses or to housing
Qty:
Part #:302092
- Features Separate overload and short-circuit elements provide time delay for sizing as close as 125% of motor FLA 2:
- 1 selective coordination amp ratio (within the Cooper Bussmann RK5 fuse family) prevents overcurrent events from opening upstream Fusetron fuses Insulated end caps for 225A-600A fuses reduces exposure to live parts and extends air gap to distance between blades of adjacent mounted fuses or to housing
Qty:
Part #:302094
- Features Separate overload and short-circuit elements provide time delay for sizing as close as 125% of motor FLA 2:
- 1 selective coordination amp ratio (within the Cooper Bussmann RK5 fuse family) prevents overcurrent events from opening upstream Fusetron fuses Insulated end caps for 225A-600A fuses reduces exposure to live parts and extends air gap to distance between blades of adjacent mounted fuses or to housing
Qty:
Part #:302100
- Features Separate overload and short-circuit elements provide time delay for sizing as close as 125% of motor FLA 2:
- 1 selective coordination amp ratio (within the Cooper Bussmann RK5 fuse family) prevents overcurrent events from opening upstream Fusetron fuses Insulated end caps for 225A-600A fuses reduces exposure to live parts and extends air gap to distance between blades of adjacent mounted fuses or to housing
Qty:
Part #:302103
- Features Separate overload and short-circuit elements provide time delay for sizing as close as 125% of motor FLA 2:
- 1 selective coordination amp ratio (within the Cooper Bussmann RK5 fuse family) prevents overcurrent events from opening upstream Fusetron fuses Insulated end caps for 225A-600A fuses reduces exposure to live parts and extends air gap to distance between blades of adjacent mounted fuses or to housing
Qty:
Part #:302105
- Features Separate overload and short-circuit elements provide time delay for sizing as close as 125% of motor FLA 2:
- 1 selective coordination amp ratio (within the Cooper Bussmann RK5 fuse family) prevents overcurrent events from opening upstream Fusetron fuses Insulated end caps for 225A-600A fuses reduces exposure to live parts and extends air gap to distance between blades of adjacent mounted fuses or to housing
Qty:
Part #:302106
- Features Separate overload and short-circuit elements provide time delay for sizing as close as 125% of motor FLA 2:
- 1 selective coordination amp ratio (within the Cooper Bussmann RK5 fuse family) prevents overcurrent events from opening upstream Fusetron fuses Insulated end caps for 225A-600A fuses reduces exposure to live parts and extends air gap to distance between blades of adjacent mounted fuses or to housing
Qty:
Part #:302107
- Features Separate overload and short-circuit elements provide time delay for sizing as close as 125% of motor FLA 2:
- 1 selective coordination amp ratio (within the Cooper Bussmann RK5 fuse family) prevents overcurrent events from opening upstream Fusetron fuses Insulated end caps for 225A-600A fuses reduces exposure to live parts and extends air gap to distance between blades of adjacent mounted fuses or to housing
Qty:
Part #:303764
- 13&frasl32 x 1-1/2 250Vac Fast-acting supplemental fuses Catalog symbol &ndash color code BAF - Green (250Vac max 1/4 to 30A) For superior protection, Bussmann recommends upgrading to Low-Peak&trade Class CC fuses.
Qty:
Part #:305466
- Catalog Number KTK-R-_ Dimensions 13/32" x 1-1/2" (10.3 x 38.1mm) Volts 600Vac (or less) Amps 1⁄10-30A IR - 200kA Vac RMS Sym Agency Information - CE - UL Listed, Std. 248-4, Class CC, UL Listed, Guide JDDZ, File E4273 - CSA Certified, File 53787, Class 1422-02, C22.2 NO. 248.4 - RoHS Compliant Typical Applications - Branch Circuits - Specialized Circuits - Industrial Control - Street Lighting (isolated, in-line fuse holders):
Qty:
Part #:306387
- 13&frasl32 x 1-1&frasl2 250Vac Time-delay supplemental fuses Catalog symbol / color code FNM - Green (250Vac maximum voltage)
Qty:
Part #:307102
- Appleton RB Series reducers are explosionproof and dust-ignitionproof. They are designed to reduce conduit entries to a smaller size and are used in threaded rigid and IMC conduit systems
$
28.89
Qty:
Displaying: 25 - 48 of 48 Matching Items