9in
Electrical Equipment
View:
Active Filters :
- Main Category: Electrical Equipment
- Length: 9in 5.5in 10.90in
Part #:302155
- Advanced Protection Energy Efficient 600Vac/300Vdc, 1/10-600A, Dual Element, Time-Delay Fuses Energy efficient Class RK5 dual element, current-limiting, time-delay fuses with optional open fuse indication on select ratings (see data sheets). Time-delay &ndash 10 second (minimum) at 500% of rated current. Fusetron fuses are on average 23% more energy efficient than the next leading brand.
Qty:
Part #:300403
- Advanced Protection Energy Efficient 600Vac/300Vdc, 1/10-600A, Dual Element, Time-Delay Fuses Energy efficient Class RK5 dual element, current-limiting, time-delay fuses with optional open fuse indication on select ratings (see data sheets). Time-delay &ndash 10 second (minimum) at 500% of rated current. Fusetron fuses are on average 23% more energy efficient than the next leading brand.
Qty:
Part #:300531
- Catalog Number LPN-RK_SP (250V), LPS-RK_SP (600V) Dimensions See data sheets Volts - LPN-RK:
- 250Vac (up to 600A), 125Vdc (up to 60A), 250Vdc (70 to 600A) - LPS-RK
Qty:
Part #:302124
- Advanced Protection Energy Efficient 600Vac/300Vdc, 1/10-600A, Dual Element, Time-Delay Fuses Energy efficient Class RK5 dual element, current-limiting, time-delay fuses with optional open fuse indication on select ratings (see data sheets). Time-delay &ndash 10 second (minimum) at 500% of rated current. Fusetron fuses are on average 23% more energy efficient than the next leading brand.
Qty:
Part #:302126
- Advanced Protection Energy Efficient 600Vac/300Vdc, 1/10-600A, Dual Element, Time-Delay Fuses Energy efficient Class RK5 dual element, current-limiting, time-delay fuses with optional open fuse indication on select ratings (see data sheets). Time-delay &ndash 10 second (minimum) at 500% of rated current. Fusetron fuses are on average 23% more energy efficient than the next leading brand.
Qty:
Part #:302793
- Catalog Number LPN-RK_SP (250V), LPS-RK_SP (600V) Dimensions See data sheets Volts - LPN-RK:
- 250Vac (up to 600A), 125Vdc (up to 60A), 250Vdc (70 to 600A) - LPS-RK
Qty:
Part #:302794
- Catalog Number LPN-RK_SP (250V), LPS-RK_SP (600V) Dimensions See data sheets Volts - LPN-RK:
- 250Vac (up to 600A), 125Vdc (up to 60A), 250Vdc (70 to 600A) - LPS-RK
Qty:
Part #:304017
- Advanced Protection Energy Efficient 600Vac/300Vdc, 1/10-600A, Dual Element, Time-Delay Fuses Energy efficient Class RK5 dual element, current-limiting, time-delay fuses with optional open fuse indication on select ratings (see data sheets). Time-delay &ndash 10 second (minimum) at 500% of rated current. Fusetron fuses are on average 23% more energy efficient than the next leading brand.
Qty:
Part #:303561
- All P&S Watertight Pin & Sleeve plugs, connectors, receptacles, and inlets bring you the features to enhance versatility, reliability, and safety. North American products come completely ready to wire, for quick, simple installation. And all feature chemical-resistant thermoplastic construction. Shrouded, nickel-plated, solid-brass pins provide corrosion protection and excellent conductivity. An exclusive, hinged cord grip eliminates loose parts that get lost. For covering patents, see www.legrand.us/patents.
Qty:
Part #:303605
- All P&S Watertight Pin & Sleeve plugs, connectors, receptacles, and inlets bring you the features to enhance versatility, reliability, and safety. North American products come completely ready to wire, for quick, simple installation. And all feature chemical-resistant thermoplastic construction. Shrouded, nickel-plated, solid-brass pins provide corrosion protection and excellent conductivity. An exclusive, hinged cord grip eliminates loose parts that get lost. For covering patents, see www.legrand.us/patents.
Qty:
Part #:310794
- Thermo-Shrink® Heavy-Wall Heat Shrink, 9" Length, 6-1 AWG
TS-46 irradiated cross-linked polyolefin with 31 standard shrink ratio
Adhesive liner provides complete insulation and protection to electrical splices in above-grade, underground or underwater applications
Maximum flame retardancy
Meets UL 486D, CSA C22.2 No. 198.2, ANSI C119.1, Western Underground Guides Nos. 2.4, 2.5, MIL-DTL-23053/15, IEEE 383 Vertical Flame Test, ANSI C37.20.2, ICEA S-19-8 and NEMA insulation thickness requirements
Rated for 600V, 90°C continuous use
Qty:
Part #:310947
- Thermo-Shrink® Heavy-Wall Heat Shrink, 9" Length, 4/0-400 MCM
TS-46 irradiated cross-linked polyolefin with 31 standard shrink ratio
Adhesive liner provides complete insulation and protection to electrical splices in above-grade, underground or underwater applications
Maximum flame retardancy
Meets UL 486D, CSA C22.2 No. 198.2, ANSI C119.1, Western Underground Guides Nos. 2.4, 2.5, MIL-DTL-23053/15, IEEE 383 Vertical Flame Test, ANSI C37.20.2, ICEA S-19-8 and NEMA insulation thickness requirements
Rated for 600V, 90°C continuous use
Qty:
Part #:311426
- Thermo-Shrink® Heavy-Wall Heat Shrink, 9" Length, 500-1,000 MCM
TS-46 irradiated cross-linked polyolefin with 31 standard shrink ratio
Adhesive liner provides complete insulation and protection to electrical splices in above-grade, underground or underwater applications
Maximum flame retardancy
Meets UL 486D, CSA C22.2 No. 198.2, ANSI C119.1, Western Underground Guides Nos. 2.4, 2.5, MIL-DTL-23053/15, IEEE 383 Vertical Flame Test, ANSI C37.20.2, ICEA S-19-8 and NEMA insulation thickness requirements
Rated for 600V, 90°C continuous use
Qty:
Displaying: 1 - 14 of 14 Matching Items