Fuses
Electrical Equipment
View:
Part #:300025
- For superior protection, Eaton recommends upgrading to Low-Peak Class CC fuses. See data sheet No. 1023.:
Qty:
Part #:301004
- Features Separate overload and short-circuit elements provide time delay for sizing as close as 125% of motor FLA 2:
- 1 selective coordination amp ratio (within the Cooper Bussmann RK5 fuse family) prevents overcurrent events from opening upstream Fusetron fuses Insulated end caps for 225A-600A fuses reduces exposure to live parts and extends air gap to distance between blades of adjacent mounted fuses or to housing
Qty:
Part #:301364
- 13&frasl32 x 1-1&frasl2 500Vac Time-delay supplemental fuses Catalog symbol / color code FNQ - Orange (500Vac maximum voltage)
Qty:
Part #:302122
- Advanced Protection Energy Efficient 600Vac/300Vdc, 1/10-600A, Dual Element, Time-Delay Fuses Energy efficient Class RK5 dual element, current-limiting, time-delay fuses with optional open fuse indication on select ratings (see data sheets). Time-delay &ndash 10 second (minimum) at 500% of rated current. Fusetron fuses are on average 23% more energy efficient than the next leading brand.
Qty:
Part #:302145
- Advanced Protection Energy Efficient 600Vac/300Vdc, 1/10-600A, Dual Element, Time-Delay Fuses Energy efficient Class RK5 dual element, current-limiting, time-delay fuses with optional open fuse indication on select ratings (see data sheets). Time-delay &ndash 10 second (minimum) at 500% of rated current. Fusetron fuses are on average 23% more energy efficient than the next leading brand.
Qty:
Part #:305133
- Advanced protection 600Vac, 1/4-30A, time-delay fuses Class CC current-limiting, time-delay fuses.
Qty:
Qty:
Part #:311746
- 13&frasl32 x 1-1&frasl2 250Vac Time-delay supplemental fuses Catalog symbol / color code FNM - Green (250Vac maximum voltage)
Qty:
Part #:301151
- 13&frasl32 x 1-1&frasl2 250Vac Time-delay supplemental fuses Catalog symbol / color code FNM - Green (250Vac maximum voltage)
Qty:
Part #:301176
- Fused and non-fused HVAC disconnects in NEMA 3R enclosures Fused pullout versions are available in 30 and 60 amp ratings with or without self-testing GFCI receptacles. Non-fused pullout versions are available in 60 amp versions with or without self-testing GFCI receptacles. There is also a 60 A non-fused switch version available.
Qty:
Part #:302084
- Features Separate overload and short-circuit elements provide time delay for sizing as close as 125% of motor FLA 2:
- 1 selective coordination amp ratio (within the Cooper Bussmann RK5 fuse family) prevents overcurrent events from opening upstream Fusetron fuses Insulated end caps for 225A-600A fuses reduces exposure to live parts and extends air gap to distance between blades of adjacent mounted fuses or to housing
Qty:
Part #:302111
- Features Separate overload and short-circuit elements provide time delay for sizing as close as 125% of motor FLA 2:
- 1 selective coordination amp ratio (within the Cooper Bussmann RK5 fuse family) prevents overcurrent events from opening upstream Fusetron fuses Insulated end caps for 225A-600A fuses reduces exposure to live parts and extends air gap to distance between blades of adjacent mounted fuses or to housing
Qty:
closeout
$19.41 MSRP
$
16.16
Qty:
Qty:
closeout
$129.48 MSRP
$
107.81
Qty:
closeout
$25.94 MSRP
$
21.60
Qty:
Displaying: 1 - 17 of 17 Matching Items