Fuses
Electrical Equipment
View:
Active Filters :
- Main Category: Electrical Equipment
- Fuses, Circuit Breakers, Load Centers, and Safety Switches: Fuses
- Application: Combination starters, motor contol centers, Machinery disconnects, power panelboards Combination Staters, motor control centers, machinery desconnects, power panelboards Inductive load circuits, electronic circuits Large distribution switchboards, power panelboards motor control centers
Part #:301004
- Features Separate overload and short-circuit elements provide time delay for sizing as close as 125% of motor FLA 2:
- 1 selective coordination amp ratio (within the Cooper Bussmann RK5 fuse family) prevents overcurrent events from opening upstream Fusetron fuses Insulated end caps for 225A-600A fuses reduces exposure to live parts and extends air gap to distance between blades of adjacent mounted fuses or to housing
Qty:
Part #:300656
- Catalog Number FNA-(amp) Dimensions 13⁄32” x 1 1⁄2” (10.3 x 38.1mm) Volts - 250Vac (1⁄10-6A) - 125Vac (6 1/4-15A) - 32Vac (20-30A) Amps 1⁄10-30A IR See data sheet # 2029 for interrupting rating by circuit voltage and fuse amp rating Agency Information - CE - UL Listed 1/10 to 8/10A @ 125/250Vac, 1-15A @ 125Vac, Guide JDYX, File E19180 - CSA Certified 1/10 to 10A @ 125Vac, Class 1422-01, File 53787 Typical Applications - Power electronic circuits with high inrush currents and fuse openings must be quickly apparent - Inductive load circuits where pin indication of open fuse condition is desired Construction - Silver-plated pin for positive, electrical signal activation - 12 amp and more versions are dual-tube construction:
Qty:
Part #:301006
- Advanced Protection Energy Efficient 600Vac/300Vdc, 1/10-600A, Dual Element, Time-Delay Fuses Energy efficient Class RK5 dual element, current-limiting, time-delay fuses with optional open fuse indication on select ratings (see data sheets). Time-delay &ndash 10 second (minimum) at 500% of rated current. Fusetron fuses are on average 23% more energy efficient than the next leading brand.
Qty:
Part #:303715
- Catalog Number LPN-RK_SP (250V), LPS-RK_SP (600V) Dimensions See data sheets Volts - LPN-RK:
- 250Vac (up to 600A), 125Vdc (up to 60A), 250Vdc (70 to 600A) - LPS-RK
Qty:
Part #:303716
- Catalog Number LPN-RK_SP (250V), LPS-RK_SP (600V) Dimensions See data sheets Volts - LPN-RK:
- 250Vac (up to 600A), 125Vdc (up to 60A), 250Vdc (70 to 600A) - LPS-RK
Qty:
Part #:303717
- Catalog Number LPN-RK_SP (250V), LPS-RK_SP (600V) Dimensions See data sheets Volts - LPN-RK:
- 250Vac (up to 600A), 125Vdc (up to 60A), 250Vdc (70 to 600A) - LPS-RK
Qty:
Part #:303721
- Advanced Protection Energy Efficient 600Vac/300Vdc, 1/10-600A, Dual Element, Time-Delay Fuses Energy efficient Class RK5 dual element, current-limiting, time-delay fuses with optional open fuse indication on select ratings (see data sheets). Time-delay &ndash 10 second (minimum) at 500% of rated current. Fusetron fuses are on average 23% more energy efficient than the next leading brand.
Qty:
Part #:304017
- Advanced Protection Energy Efficient 600Vac/300Vdc, 1/10-600A, Dual Element, Time-Delay Fuses Energy efficient Class RK5 dual element, current-limiting, time-delay fuses with optional open fuse indication on select ratings (see data sheets). Time-delay &ndash 10 second (minimum) at 500% of rated current. Fusetron fuses are on average 23% more energy efficient than the next leading brand.
Qty:
Displaying: 1 - 8 of 8 Matching Items