PVC
Electrical Equipment
View:
Active Filters :
- Main Category: Electrical Equipment
- Material: PVC Steel
- Electrical Boxes, Conduit, Strut, and Raceway: Electrical Fittings
Part #:300005
- Appleton and O-Z/Gedney offer NEER zinc gland compression connectors and couplings. TC-600 couplings are used to join lengths of steel EMT for concretetight dry or damp location applications. TC-600 connectors are used to secure and terminate steel EMT to knockouts in concretetight box dry or damp location applications.
$
1.44
Qty:
$
2.46
Qty:
$
3.19
Qty:
$
4.19
Qty:
Part #:301272
- CANTEX 6141625 is a 1 in. Schedule 40 Standard Center Stop Coupling used to join lengths of conduit pipe together with two solvent weld socket ends
Features
For use with Schedule 40 and Schedule 80 conduit. May also be used in EB & DB Duct applications.
Center stop to help determine proper depth of connection
For use aboveground and underground and non-conductive and sunlight resistant
Meets NEMA TC-3 Standards
UL and CSA listed
Made in USA
$
0.21
Qty:
Part #:301354
- CANTEX 6141630 is a 3 in. Schedule 40 Standard Center Stop Coupling used to join lengths of conduit pipe together with two solvent weld socket ends
Features
For use with Schedule 40 and Schedule 80 conduit. May also be used in EB & DB Duct applications.
Center stop to help determine proper depth of connection
For use aboveground and underground and non-conductive and sunlight resistant
Meets NEMA TC-3 Standards
UL and CSA listed
Made in USA
$
1.43
Qty:
Part #:301356
- CANTEX 6141632 is a 4 in. Schedule 40 Standard Center Stop Coupling used to join lengths of conduit pipe together with two solvent weld socket ends
Features
For use with Schedule 40 and Schedule 80 conduit. May also be used in EB & DB Duct applications.
Center stop to help determine proper depth of connection
For use aboveground and underground and non-conductive and sunlight resistant
Meets NEMA TC-3 Standards
UL and CSA listed
Made in USA
$
2.20
Qty:
Part #:301402
- CANTEX 5140112 is a 4 in. Male Terminal Adapter which is a connector used to transition from a spigot end PVC conduit to a threaded metal or PVC plastic female bell end
Features
Durable non-conductive PVC will not rust or corrode
For use with Schedule 40 and Schedule 80 conduit. May also be used in EB & DB Duct applications.
Meets NEMA TC-3 Standards
UL and CSA listed
Made in USA
$
3.02
Qty:
Part #:301405
- CANTEX 5133828 is a 2 in. x 90-Degree Plain End Schedule 40 Standard Radius Elbow used to change the direction of a conduit run by 90-Degree
Features
Schedule 40 Nonmetallic PVC construction for strength and durability
For indoor or outdoor use
Suitable for aboveground or buried
Plain-end connections are solvent weld
ETL listed Conforms to UL 651 and NEMA TC-3 Conforms to UL 651 and NEMA TC-3
Made in USA
$
2.09
Qty:
Part #:301414
- CANTEX 5133832 is a 4 in. x 90-Degree Plain End Schedule 40 Standard Radius Elbow used to change the direction of a conduit run by 90-Degree
Features
Schedule 40 Nonmetallic PVC construction for strength and durability
For indoor or outdoor use
Suitable for aboveground or buried
Plain-end connections are solvent weld
ETL listed Conforms to UL 651 and NEMA TC-3 Conforms to UL 651 and NEMA TC-3
Made in USA
$
28.17
Qty:
Part #:301487
- CANTEX 5133821 is a 4 in. x 90-Degree x 36 in. Radius Plain End Schedule 40 Special Radius Elbow used to change the direction of a conduit run by 90-Degree
Features
Schedule 40 Nonmetallic PVC construction for strength and durability
For indoor or outdoor use
Suitable for aboveground or buried
Plain-end connections are solvent weld
ETL listed Conforms to UL 651 and NEMA TC-3 Conforms to UL 651 and NEMA TC-3
Made in USA
$
87.11
Qty:
Part #:303756
- CANTEX 5133836 is a 2 in. x 90-Degree x 24 in. Radius Plain End Schedule 40 Special Radius Elbow used to change the direction of a conduit run by 90-Degree
Features
Schedule 40 Nonmetallic PVC construction for strength and durability
For indoor or outdoor use
Suitable for aboveground or buried
Plain-end connections are solvent weld
ETL listed Conforms to UL 651 and NEMA TC-3 Conforms to UL 651 and NEMA TC-3
Made in USA
$
22.99
Qty:
Part #:304347
- CANTEX 5133825 is a 1 in. x 90-Degree Plain End Schedule 40 Standard Radius Elbow used to change the direction of a conduit run by 90-Degree Features Schedule 40 Nonmetallic PVC construction for strength and durability For indoor or outdoor use Suitable for aboveground or buried Plain-end connections are solvent weld ETL listed Conforms to UL 651 and NEMA TC-3 Conforms to UL 651 and NEMA TC-3 Made in USA
$
1.56
Qty:
Part #:305112
- Appleton and O-Z/Gedney offer NEER zinc set screw offset nipples. The TN-50 is a set screw type offset connector with locknut. It is used to make a slight adjustment in terminating the end of a run of EMT to an enclosure or box.
$
8.96
Qty:
Part #:309685
- Appleton and O-Z/Gedney offer NEER zinc gland compression connectors and couplings. TC-600 couplings are used to join lengths of steel EMT for concretetight dry or damp location applications. TC-600 connectors are used to secure and terminate steel EMT to knockouts in concretetight box dry or damp location applications.
$
0.92
Qty:
$
4.76
Qty:
Part #:309835
- Appleton and O-Z/Gedney offer NEER zinc gland compression connectors and couplings. TC-600 couplings are used to join lengths of steel EMT for concretetight dry or damp location applications. TC-600 connectors are used to secure and terminate steel EMT to knockouts in concretetight box dry or damp location applications.
$
1.85
Qty:
Part #:310706
- Appleton and O-Z/Gedney offer NEER zinc gland compression connectors and couplings. TC-600 couplings are used to join lengths of steel EMT for concretetight dry or damp location applications. TC-600 connectors are used to secure and terminate steel EMT to knockouts in concretetight box dry or damp location applications.
$
1.63
Qty:
Displaying: 1 - 24 of 80 Matching Items