Fiat
HVAC and Plumbing
View:
Active Filters :
- Main Category: HVAC and Plumbing
- Brand: Fiat Honeywell Residential Maxitrol
Part #:284-S87C1030
- HONS87C1030 Dsi Control 21 Sec. Lockout,dual Rod
Part Description
Ignition Control Module
Type Direct Spark, Electronic, Pilot
Fuel Type Natural/Liquid Propane Gas
Flame Sense Type Two Rod
Ignition Source Internal High Voltage Spark Generator
Ignition Sequence 1-Trial
Ignition Trial Time 21 Second
Flame Failure Response Time 0.8 Second at 5 Microamp
Power Rating 24 Volt AC at 60 Hertz
Size 4-1/16 Inch Width x 1-15/16 Inch Length x 5-1/4 Inch Height
Temperature Rating -40 to 175 Deg F
Application Gas Fired Furnace, Boiler, Heating Appliance
Approval CSA
Lockout Timing 21 Second
Flame Failure Re-Ignition Time 0.8 Second
Qty:
Part #:284-S8610U3009
- HONS8610U3009 Universal Intermittent Pilot Control For Lp & Natural Gas With Field Selectable Prepurge & Ignition Trial Timings, For Single & Dual Rod Applications, Suitable For Use With Vent Dampers
Part Description
Ignition Control Module
Type Universal, Intermittent Pilot
Fuel Type Natural/Liquid Propane Gas
Flame Sense Type Single or Dual Rod
Ignition Source Internal High Voltage Spark Generator
Ignition Sequence Continuous Retry
Ignition Trial Time 15/90 Second
Prepurge Time Configurable to 30 Second/No Pre-Purge
Flame Failure Response Time 2 Second
Valve Rating 1 Amp Pilot/2 Amp Main at 165 Deg F, 1 Amp Pilot/Main at 175 Deg F
Power Rating 24 Volt AC at 60 Hertz
Size 5-7/16 Inch Width x 2-5/8 Inch Depth x 3-15/16 Inch Height
Temperature Rating -40 to 165 Deg F
Application Warm Air Furnace, Heating Appliance
Approval CSA
Includes Damper Connection, Automatic Vent Damper Plug
Qty:
Part #:284-WT8840B1000
- HONWT8840B1000 Water Heater Gas Valve, Standing Pilot With Piezo, Setpoint 55-155f, Spud Length 1", Bracket=centered, Reg Setting 5" Wc, Natural Gas
Part Description
Water Heater Control
Item Water Heater Control
Type 90 Degree
Port Connection 1/2 Inch Threaded x 1/2 Inch Inverted Flare
Input Supply Rating 350 to 850 Millivolt DC
Temperature Rating 0 to 150 Deg F
Pressure Rating 5 Inch WC
Media Handled Gas
Inclusions/Features Integrated NTC Temperature Sensor
Application Water Heater
Applicable Standard CSA 6.20/4.6, CAN/CSA C22.2, ANSI Z21.20/Z21.23/Z21.78/Z21.87
Tank Insulation Size 1 Inch
Ambient Temperature 32 to 150 Deg F, -40 to 150 Deg F (Storage), 55 Deg F to 155 Deg F Valve (Set Point)
Mounting Position Upright
Capacity 30 Foot per 3 Hour to 75 Foot per 3 Hour
Humidity 95 Percent (Non-Condensing) at 104 Deg F
Qty:
Part #:284-325-7A-1-1/4IN
-
MAX325-7A-1 1/4" 1-1/4" Gas Pressure Regulator 1,250,000 BTU Use With R8110 Series Spring... Comes W/standard Spring Is 4-12",10 PSI Max Inlet Pressure,replaces 325-7-1-1/4" 1010 = 1-1/4"
Part Description
Gas Pressure Regulator
Actuation Type Lever
Nominal Size 1-1/4 Inch
End Connection Female Threaded x Female Threaded
End to End Distance 8 Inch
Body Material Aluminum
Temperature Rating 40 to 205 Deg F
Pressure Rating 2/5/10 PSI (Inlet), 65 PSI (Emergency Exposure Limit)
Application Residential, Commercial, Industrial
Applicable Standard CSA (Canada and US), CE, ANSI Z21.18/CSA 6.3
Gas Type Natural, Mixed Gas, Liquefied Petroleum Gas and LP Gas Air Mixture
Vent Pipe Connection 1/2 Inch Threaded
Swing Radius 6.1 Inch
Spring Size 4 to 12 Inch WC
Height 7.3 Inch
Individual Load Rating 1250000 BTU/Hour
Capacity 1250000 BTU/Hour
Qty:
Part #:284-MAX325-7A-1 1/2IN
- MAX325-7A-1 1/2" 1-1/2" Gas Pressure Regulator 1,250,000 Btu Use With R8110 Spring Comes With Standard 4-12" Spring Replaces 325-7-1 1/2" 10 Psi Max Inlet
Part Description
Gas Pressure Regulator
Actuation Type Lever
Nominal Size 1-1/2 Inch
End Connection Female Threaded x Female Threaded
End to End Distance 8 Inch
Body Material Aluminum
Temperature Rating 40 to 205 Deg F
Pressure Rating 2/5/10 PSI (Inlet), 65 PSI (Emergency Exposure Limit)
Application Residential, Commercial, Industrial
Applicable Standard CSA (Canada and US), CE, ANSI Z21.18/CSA 6.3
Gas Type Natural, Mixed Gas, Liquefied Petroleum Gas and LP Gas Air Mixture
Vent Pipe Connection 1/2 Inch Threaded
Swing Radius 6.1 Inch
Spring Size 4 to 12 Inch WC
Height 7.3 Inch
Individual Load Rating 1250000 BTU/Hour
Qty:
Part #:284-MAXR8110-1022
- MAXR8110-1022 Red Spring For RV81,210D,325-7 10-22"
Part Description
Gas Pressure Regulator Spring
MROSCS Leaf Class Name Valve Spring
Used On Item Gas Pressure Regulator
Used On Model/Brand RV81, 210D, 325-7A
Color Code Red
Overall Dimension 7/8 Inch Inner Diameter x 4-5/16 Inch Length
Outlet Pressure 10 to 22 Inch WC
$
39.35
Qty:
Part #:284-12A49
- MAX12A49 1/2" NPT. Automatic Vent Limiting Device For 325-7 & 325-9 Series, OPD210E
Part Description
Gas Pressure Regulator Vent Limiter
MROSCS Leaf Class Name Valve Limiter
Type Automatic
Material Brass
Used On Item Gas Pressure Regulator
Used On Model/Brand 325-7A, 325-7AL, 325-9, 325-9L, OPD210E
Applicable Standard CSA, ANSI
Nominal Size 1/2 Inch Threaded
Pressure Rating 2 PSI (Liquid Propane), 5 PSI (Natural)
$
175.00
Qty:
Part #:284-MAX13A25
- MAX13A25 Outdoor Vent Protector Kit For 325-7, 325-9, RV91 Series & 210E Series 1/2" Npt. (rain Cover)
Part Description
Gas Pressure Regulator Vent Protector
MROSCS Leaf Class Name Valve Protector
Used On Item 1/2 Inch Threaded Gas Pressure Regulator Vent
Used On Model/Brand 325-7A, 325-7AL, 325-9, 325-9L, RV91, 210E
Applicable Standard CSA (Canada and US)
Mounting Position Upright
Application Outdoor
$
93.95
Qty:
Part #:284-325-5-1IN
-
MAX325-5-1" 1" Gas Pressure Regulator For Up To 10 PSI Use With R325E10 Spring Includes 12A39 Vent Limiter & Standard 4-12" Spring 325,000 BTU Replaces 325-5A-1"
Part Description
Gas Pressure Regulator
Actuation Type Lever
Nominal Size 1 Inch
End Connection Female Threaded x Female Threaded
End to End Distance 5.9 Inch
Body Material Aluminum
Temperature Rating 40 to 205 Deg F
Pressure Rating 2/5/10 PSI (Inlet), 65 PSI (Emergency Exposure Limit)
Application Residential, Commercial, Industrial
Applicable Standard CSA (Canada and US), CE, ANSI Z21.18/CSA 6.3
Gas Type Natural, Mixed Gas, Liquefied Petroleum Gas and LP Gas Air Mixture
Vent Pipe Connection 3/8 Inch Threaded
Swing Radius 4.9 Inch
Spring Size 4 to 12 Inch WC
Height 5.3 Inch
Individual Load Rating 325000 BTU/Hour
Capacity 325000 BTU/Hour
Qty:
Part #:284-325-5-3/4IN
-
MAX325-5-3/4" 3/4" Gas Pressure Regulator For Up To 10 PSI Use R325E10 Spring Includes 12A39 Vent Limiter & Standard 4-12" Spring 325,000 BTU Replaces 325-5A-3/4"
Part Description
Gas Pressure Regulator
Actuation Type Lever
Nominal Size 3/4 Inch
End Connection Female Threaded x Female Threaded
End to End Distance 5.9 Inch
Body Material Aluminum
Temperature Rating 40 to 205 Deg F
Pressure Rating 2/5/10 PSI (Inlet), 65 PSI (Emergency Exposure Limit)
Application Residential, Commercial, Industrial
Applicable Standard CSA (Canada and US), CE, ANSI Z21.18/CSA 6.3
Gas Type Natural, Mixed Gas, Liquefied Petroleum Gas and LP Gas Air Mixture
Vent Pipe Connection 3/8 Inch Threaded
Swing Radius 4.9 Inch
Spring Size 4 to 12 Inch WC
Height 5.3 Inch
Individual Load Rating 325000 BTU/Hour
Capacity 325000 BTU/Hour
Qty:
Part #:284-RV48CL 3/4
- 3/4\" Gas Pressure Regulator 250,000 BTU Use With R4810 Spring 5\" Natural / 10\" LP Maximum 1/2 PSI Inlet Pressure Single Appliance Only
Part Description
Gas Pressure Regulator
Type Poppet
Nominal Size 3/4 Inch
End Connection Female Threaded x Female Threaded
End to End Distance 3.4 Inch
Body Material Aluminum
Seat Material Rubber
Temperature Rating 32 to 225 Deg F
Pressure Rating 1/2 PSI (Inlet), 2.5 PSI (Emergency Exposure Limit)
Inclusions/Features Integral Vent Limiting Orifice as the Breather Hole, Convertible Regulator
Application Burner and Pilot Load, Residential and Commercial Cooking Appliance, Barbecue, Hearth Product, Pilot Line
Applicable Standard CSA (Canada and US), CE, ANSI Z21.18/CSA 6.3
Gas Type Natural, Mixed Gas, Liquefied Petroleum Gas and LP Gas Air Mixture
Vent Type Integral/1/8 Inch Threaded, 12A04/12A06 Limiting Device
Swing Radius 2 Inch
Size 3 Inch Width x 2.8 Inch Height
Pressure Drop Rating 150000 BTU/Hour
Qty:
Part #:284-MAXR400S-1/2
- MAXR400S-1/2 1/2" Gas Pressure Regulator 300,000 BTU Use With R400B10 Spring Comes Standard W/ 3-6" Replaces RV42 1/2" Single Appliance Only
Part Description
Gas Pressure Regulator
Type Double Diaphragm Balanced Valve
Nominal Size 1/2 Inch
End Connection Female Threaded x Female Threaded
End to End Distance 2 Inch
Body Material Aluminum
Temperature Rating -40 to 250 Deg F
Pressure Rating 5 PSI (Inlet), 12.5 PSI (Emergency Exposure Limit)
Application Burner and Pilot Load, Infrared Heater and Pilot Line
Applicable Standard UL, CSA (Canada and US), CE, ANSI Z21.18
Gas Type Natural, Mixed Gas, Liquefied Petroleum Gas and LP Gas Air Mixture
Vent Pipe Connection 1/8 Inch Threaded
Swing Radius 2.4 Inch
Size 2 Inch Width x 3.3 Inch Height
Pressure Drop Rating 303 BTU/Hour
Qty:
Part #:284-VR8200A2132
- Substitute Items:
- W-R36C03-300 24v 1/2" X 3/4" Standing Pilot Thermocouple Actuated Gas Valve With LP Kit HONVR8200A2124 24v Standing Pilot Natural Gas Valve 1/2" X 1/2" W/36" Thermocouple & LP Kit 130,000 BTU RBS720-400 24v 1/2" X 3/4" Standing Pilot Gas Valve Includes LP Kit & Bushings 150,000 BTU RBS720-402 24v 1/2" X 3/4" Standing Pilot Dual Gas Valve-150,000 Btu Includes Lp Kit & Side Outlets 7200er Replaces 720-401 RBS720-406 24v 3/4" X 3/4" Standing Pilot Gas Valve Includes Lp Kit & Bushings 150,000 Btu 7200er Replaces 7a8-a1b-007
Qty:
Part #:284-VR8245M2530
- HONVR8245M2530 24Vac Dual Intermittent Pilot, Direct Spark, Or Hot Surface Ignition Gas Valve With 1/2" x 1/2" Inlet/Outlet, Standard Opening and 3.5" WC Pressure Regulator Setting, Includes LP Kit
Part Description
Gas Valve
Type Universal Electronic/Direct/Intermittent Pilot Operated, 1-Stage, Straight-Through
Port Connection 1/2 Inch Compression x 1/2 Inch Compression
Input Supply Rating 24 Volt AC at 50/60 Hertz
Temperature Rating -40 to 175 Deg F
Pressure Rating 1/2 PSI
Mounting Details 0 to 90 Degree in any Direction from Upright Position of Gas Control Knob, Including Vertically
Media Handled Gas
Inclusions/Features (1) 1/2 Inch x 3/8 Inch Reducer Bushing, Natural to Liquid Propane Conversion Kit, Standard Opening, Manual Valve, (2) Automatic Operator, Pressure Regulator, Pilot Adjustment, Pilot Plug and Ignition Adapter, Low Voltage
Application Residential Gas Fired Appliance
Applicable Standard UL, CSA
Overall Dimension 4-1/16 Inch Width x 2-11/16 Inch Depth x 5-3/8 Inch Height
Pressure Regulator Setting 3.5 Inch WC
Pressure Tapping Size 1/8 Inch Threaded with Plug
Flow Capacity 20 to 200 CFH
Electrical Connection 1/4 Inch Quick Connect Male Terminal
Qty:
Part #:284-MAXR400ZM-1/2 1/2IN
- MAXR400ZM-1/2 1/2" Gas Pressure Regulator With Zero Governer Includes Brown Spring - 1-3" W.c. B.s.p. Pl parallel thread
Qty:
Part #:284-MAXR400B10-13
- MAXR400B10-13 Brown Spring For R400 & R400S 1" - 3.5"
$
4.85
Qty:
Maxitrol Outdoor Vent Protector Kit/Rain Cover for 325-7/325-9/RV91/210E Regulators (Replaces 13A25)
- MAX13A32-50 Outdoor Vent Protector Kit For 325-7, 325-9, RV91 Series & 210E Series 1/2" NPT. (Rain Cover) Replaces 13A25
Part Description
Gas Pressure Regulator Vent Protector
MROSCS Leaf Class Name Valve Protector
Used On Item 1/2 Inch Threaded Gas Pressure Regulator Vent
Used On Model/Brand 325-7A, 325-7AL, 325-9, 325-9L, RV91, 210E
Applicable Standard CSA (Canada and US)
Mounting Position Upright
Application Outdoor
$
76.25
Qty:
Part #:284-L4064B2210
- HONL4064B2210 Fan & Limit W/11" Insertion
Fan and Limit Controller
Type 11-1/2 Inch Length Element Insertion, Surface/Universal Mounting Bracket
Temperature Range -40 to 190 Deg F
Maximum Temperature Rating 190 Deg F (Switch), 350 Deg F (Element), 100 to 250 Deg F (High Limit), 65 to 215 Deg F (Fan ON), 50 to 200 Deg F (Fan OFF), 200 Deg F (High Limit Stop), 125 Deg F (Fan ON Stop), 100 Deg F (Fan OFF Stop)
Contact Rating 14 Amp at 120 Volt AC/7 Amp at 240 Volt AC Fan (Full Load), 8 Amp at 120 Volt AC/4 Amp at 240 Volt AC Limit (Full Load), 84 Amp at 120 Volt AC/42 Amp at 240 Volt AC Fan (Locked Rotor), 48 Amp at 120 Volt AC/24 Amp at 240 Volt AC Limit (Locked Rotor), 0.25 Amp at 0.25 to 12 Volt AC/2 Amp at 24 Volt AC (Pilot Duty)
Contact Configuration Fan Switch Makes, High Limit Switch Breaks on Temperature Rise
Connection Type Auxiliary Screw Terminal
Application Forced Warm Air Heating System
Approval UL, CSA
Overall Dimension 3 Inch Width x 1-19/32 Inch Depth x 4-9/32 Inch Height
Differential Temperature Rating 25 Deg F (High Limit)
Includes Manual and Automatic Fan On/Off Setting, Breakaway Jumper
Qty:
Displaying: 1 - 19 of 19 Matching Items