Armstrong International
Fernco
View:
Active Filters :
Qty:
Part #:204581
- 0600 ULFM-KSRW-Gate Valve
OS&Y Open Left with 3/4in Galvanized Pipe
Tapped and Plugged at Postion "A"
Flange x Flange
304SS Fasteners
304SS Stem
$
1,346.63
Qty:
Part #:206990
- 1406024:
Qty:
Qty:
Part #:206004
- 1406032:
$
54.00
Qty:
Part #:785-1406080
- Unshielded Rubber Coupling 6" Corrugated x 6" Cast Iron/Plastic
$
79.53
Qty:
Part #:200456
- 0600 KS-FW/SS B&N-MJ-NRS-CI
0600 KSFW (Resilent Seated Gate Valve)
NRS Dual Rated
Body/Bonnet C509 Cast Iron
Ends MJ
Wedge EPDM Encapsulated
Pain FBE
Cast (9.5-15 Mils DFT)
Mach (6-9 Mils DFT)
Hardware 304SS
Stem O/L C86700
Seal O-Ring
Gear/Motor N/A
Tap None
Operator 2in Op Nut
$
1,623.09
Qty:
$
2,170.13
Qty:
Qty:
$
50.88
Qty:
$
135.00
Qty:
Part #:501-D27090
- AEH Series Exhaust Heads Armstrongs AEH series carbon steel exhaust heads should be used when there is a risk of water carryover up an atmospheric vent pipe. The internal knock-out plate and stainless steel mesh screening effectively contains water carry-over and discharges it through the bottom drain leaving dry flash steam to vent through the top of the vessel.
Connections
• Flanged ASME B16.5 CL 150
• Drain FNPT
Qty:
Part #:501-D39124
- DS Series In-Line Condensate SeparatorsCarbon Steel Drain SeparatorCondensate in steam and air piping reduces thermal efficiency, causes water hammer, corrodes equipment such as valves and pipes, and causes other problems.
In-line (drain) separators DS-1, DS-2, DS-3, and DS-4 separate condensate efficiently by using the centrifugal force of steam or air created by introducing it into a specifically shaped path. Because of the simple structure of the drain separators, pressure loss is minimized, enabling clean, dry steam or air to be fed to equipment.
When steam or air flow enters the drain separator, centrifugal force is generated in the fluid because of the devices internal structural design. The fluid drains along the wall because of the difference in specific gravity with steam or air, eventually striking the baffle. The baffle guides the fluid to the drain outlet and to the trap, which drains it. As a result, small dirt particles and condensate are separated and removed from the system through the bottom drain.
• Cyclone structure maximizes liquid separation efficiency
• Pressure loss is extremely low
• No moving parts means no breakdowns
Qty:
Part #:501-D502638
- A/CA Series Cast Iron Y-Type Pipe Strainer Y-Type Cast Iron Strainer
• 250lb Screwed 1/2in - 3in
• Class 125 Flanged 2in - 6in
• Class 250 Flanged 2in - 6inScreen chambers won't leak or crush
Both ends of the chambers are precisely machined. This means perfectly round and smooth seating surfaces, as well as a fixed chamber length. Since the screen seats snugly on the machined surface, no particle bigger than the screen opening can escape around the end of the screen.
Screwed retainers easy in, easy out
Straight threads mean it takes less torque to achieve a tight seal with proper gasket compression. Less torque is also required to remove the retainer. For you, that means less danger of "freezing in" than with hard-to-break tapered pipe threads.
Off-center blowdown connections for better dirt removal
Off-center drains on 2-1/2" and 3" strainers allow you to remove liquid and dirt nearly completely when blowing down the strainer. Also, less liquid will spill when the screen retainer is removed.
Many screen choices
Many screen materials, meshes and perforations are available.
Qty:
Part #:206008
- Shielded 6" Clay x 6" Cast Iron/Plastic
$
117.00
Qty:
Displaying: 1 - 15 of 15 Matching Items