Armstrong International
Campbell


Displaying: 1 - 24 of 506 Matching Items
506 Items
View:
Active Filters :
Part #:511851
3/4" Wire Rope Clip, Forged Carbon Steel, Galvanized Base is Drop-Forged Carbon Steel Hot Galvanized to ASTM A-153 to Resist Rust and Corrosion U-Bolts Are colored Blue for Identification Purposes and Use Heavy Duty Hex Nuts (UNC-2A) Designed to Meet Federal Specifications, FF-C-450, Type 1, Class 1 Designed to Meet or Exceed All Requirements of ASME B30.26 Including Identification, Ductility, Design Factor and Temperature Permanently Marked with Size and Manufacturer Sizes 1/4" and Above Marked with USA and Date Code Sizes 1/8" Through 1-1/4" Are Supplied Bagged and Unassembled Note See Application and Warning Information
$22.86 MSRP $ 13.04
Qty:
add to cart
Part #:511897
3/4" Anchor Shackle, Screw Pin, Forged Carbon Steel, Painted Blue Shackle Bodies Are Drop-Forged Carbon Steel Self Colored (Painted Blue) C-419-S Shackles Meet the Design Requirements of Federal Specification RR-C-271, Type IVA, Grade A, Class 2 Working Load Limit, Size, Manufacture Name, Date Code and USA Permanently Marked on Each Shackle Statistically Tested for Impact Resistance, Tensile Strength, Hardness, Ductility and Fatigue 419 Series Shackles Meet or Exceed All Manufacturing Requirements of the ASME B30.26 &rdquoRigging Hardware&rdquo. These Include the Material Ductility Requirement (Section 26-1.1.2), the Design Factor Requirement (Section 26.1.2), the Identification Requirement (Section 26-1.5.1), and the Effective Temperature Range (Section 26-1.6.1). the Shackles Can Be Proof Tested in Accordance with Section 26-1.4 Certification Available Upon Request 6 to 1 Design Factor Pins and Bolts Are Heat-Treated and Made of Alloy Steel
$53.51 MSRP $ 29.73
Qty:
add to cart
Part #:511923
Universal Replacement Latch Kit, For Hook Sizes 2-22 (1/4") Always Inspect the Hook and Latch Before Using Always Make Sure the Spring Forces the Latch Against the Point of Hook Check the Load Before Lifting to Make Sure the Hook (Not the Latch) is Supporting Load To Assemble Latch on Hook, Follow Instructions Supplied with Latch Kit Clapper Latches Are Zinc Plated Spring Spacer Adapts Latch to Hooks with Narrow Cam Bolt and Nut Permit Fast, Easy Installation Note Latches Listed on This Page Cannot Be Used on Campbell'S Current Design of Integrated Sling and Hoist Hooks. Please Refer to the Appropriate Catalog Pages for These Hooks for Proper Replacement Latch Kits.
$9.56 MSRP $ 5.46
Qty:
add to cart
Part #:805434
INSUL-TUBE® products are non-porous, non-fibrous and are approved by Factory Mutual Research Corporation. APPLICATIONS Air conditioning Cold water Chilled water Refrigeration Duct wrap Hot water:
$ 1.25
Qty:
add to cart
Part #:511960
3/4" x 6" Jaw &amp Jaw Turnbuckle, Forged Carbon Steel, Galvanized Drop-Forged Carbon Steel Galvanized to Meet ASTM A-153 Specifications 5 to 1 Design Factor Meets Design Requirements of ASTM F1145, Type 1, Grade 1, Class G Jaws on Sizes 1/4&rdquo Through 5/8&rdquo Have Hex Head Bolt and Nut Jaws on Sizes 3/4&rdquo Through 1-1/2&rdquo Have Cotter Key and Bolt IMPORTANT Instructions For Use Turnbuckles are Designed for a Static Load In Loads Where There is Vibration, Lock Nuts (Jam Nuts) Should be Used to Prevent the Connection from Turning or Loosening DO NOT EXCEED THE WORKING LOAD LIMIT
$132.76 MSRP $ 75.80
Qty:
add to cart
Part #:511961
3/4" x 9" Jaw &amp Jaw Turnbuckle, Forged Carbon Steel, Galvanized Drop-Forged Carbon Steel Galvanized to Meet ASTM A-153 Specifications 5 to 1 Design Factor Meets Design Requirements of ASTM F1145, Type 1, Grade 1, Class G Jaws on Sizes 1/4&rdquo Through 5/8&rdquo Have Hex Head Bolt and Nut Jaws on Sizes 3/4&rdquo Through 1-1/2&rdquo Have Cotter Key and Bolt IMPORTANT Instructions For Use Turnbuckles are Designed for a Static Load In Loads Where There is Vibration, Lock Nuts (Jam Nuts) Should be Used to Prevent the Connection from Turning or Loosening DO NOT EXCEED THE WORKING LOAD LIMIT
$168.18 MSRP $ 96.04
Qty:
add to cart
Part #:713370
Y-Type Cast Iron Strainers 250 lb Screwed 1/2"-3" Class 125 Flanged 2"-6" Class 250 Flanged 2"-6" Screen chambers won't leak or crush Both ends of the chambers are precisely machined. This means perfectly round and smooth seating surfaces, as well as a fixed chamber length. Since the screen seats snugly on the machined surface, no particle bigger than the screen opening can escape around the end of the screen. Screwed retainers easy in, easy out Straight threads mean it takes less torque to achieve a tight seal with proper gasket compression. Less torque is also required to remove the retainer. For you, that means less danger of "freezing in" than with hard-to-break tapered pipe threads. Off-center blowdown connections for better dirt removal Off-center drains on 2-1/2" and 3" strainers allow you to remove liquid and dirt nearly completely when blowing down the strainer. Also, less liquid will spill when the screen retainer is removed. Many screen choices Many screen materials, meshes and perforations are available
$770.00 MSRP $ 628.05
Qty:
add to cart
Part #:511877
3/4" Connecting Link, Forged Carbon Steel, Galvanized, 5 Pcs per Box Drop-Forged Heat-Treated Carbon or Alloy Steel Standard Finish is Self-Colored or Galvanized to Meet ASTM A-153 Specifications 4 to 1 Design Factor For Proper Closure, Peen the Prongs to Fill the Hole of the Mating Half as Much as Possible Meets Design Requirements of Federal Specification RR-C-271D, Type II Make Sure the Connecting Link Used is the Same Size as the Components Being Joined. e.g., a 3/8 in. Connecting Link is Used with 3/8 in. Chain Any Assembly Made Using Connecting Links Should be Rated at the Working Load Limit of the Weakest Component. The Working Load Limit of Connecting Links is Based on a Straight Line Pull. Any Side or Shock Loading Will Significantly Reduce the Actual Working Load Limit. NEVER Re-Use a Connecting Link DO NOT EXCEED THE WORKING LOAD LIMIT
$42.71 MSRP $ 24.38
Qty:
add to cart
Part #:511945
3/4" Heavy Wire Rope Thimble, Galvanized Standard Material Hot Rolled, Mild Steel Galvanized Imported A Thimble is a Wear Pad That Protects the Rope From Cuts, Kinking and Abrasions. Always Use An Appropriate Thimble When Making An Eye in a Rope. When it is Necessary to Open a Thimble to Insert a Fitting, Make Sure the Points are Properly Aligned When the Thimble is Closed. Inspect Carefully for Cracks. Thimbles ARE NOT Designed for Load Carrying Purposes Therefore Working Load Limits Have Not Been Established.
$13.31 MSRP $ 7.60
Qty:
add to cart
Part #:501-A21862
CD-33 Series Disc Steam TrapFor steam service up to 600 psig (42 barg) Capacities to 2,500 lb/hr (1,134 kg/hr). The Armstrong CD-33 is a disc-style trap designed to control the traps cycle rate. By reducing the cycle rate, the Armstrong CD-33 extends its service life well beyond that of typical disc traps. This enhanced performance minimizes maintenance time and greatly reduces steam costs. The CD-33 is designed with three discharge ports, which offer stable disc operation to extend operating life. The capacities of the Armstrong CD-33 have been engineered specifically for the following applications large steam main drips, process equipment and HVAC heating equipment on constant pressure. The CD-33L (low capacity) trap is designed for the low capacity applications of steam main drips and steam tracing lines. By ensuring that the capacities are designed to suit the applicationand are not oversizedthe CD-33 Series will last longer than other disc traps with excessive capacity ratings. Heres why &#8226 Three-discharge port design &#8226 Minimum wear with controlled cycling &#8226 Freeze resistant &#8226 Hardened seat and disc
$544.00 MSRP $ 450.54
Qty:
add to cart
Part #:501-B2311C-2
Steam Trap ConnectorsBesides 2000 Series stainless steel inverted bucket traps, the standard 360 connector or IS-2 connector with integral strainer can also be used on many Armstrong thermostatic, disc, bimetallic, and float and thermostatic traps. Any manufacturers two-bolt steam traps can use Armstrong connectors. IS-2 Stainless Steel Connector with Integral Strainer &#8226 A full line stainless steel strainer in the connector eliminates leak points and reduces installation time &#8226 A strainer that is not discarded when the trap is replaced &#8226 Easy strainer screen replacement &#8226 Optional blowdown valve &#8226 Accommodates Armstrongs inverted bucket, disc, thermostatic, thermostatic wafer, bimetallic, and float and thermostatic traps. Any manufacturers 2-bolt steam trap can also be applied to Armstrongs S-2 connector. Standard 360 Stainless Steel Connector &#8226 A compact, lightweight assembly &#8226 Standardization, reducing inventory &#8226 A compact design, simplifying piping &#8226 Accommodates Armstrongs inverted bucket, disc, thermostatic, thermostatic wafer and bimetallic steam traps. Any manufacturers 2-bolt steam trap can also be applied to Armstrongs standard connector.
$218.10 MSRP $ 172.40
Qty:
add to cart
Part #:501-B2311D-2
Steam Trap ConnectorsBesides 2000 Series stainless steel inverted bucket traps, the standard 360 connector or IS-2 connector with integral strainer can also be used on many Armstrong thermostatic, disc, bimetallic, and float and thermostatic traps. Any manufacturers two-bolt steam traps can use Armstrong connectors. IS-2 Stainless Steel Connector with Integral Strainer &#8226 A full line stainless steel strainer in the connector eliminates leak points and reduces installation time &#8226 A strainer that is not discarded when the trap is replaced &#8226 Easy strainer screen replacement &#8226 Optional blowdown valve &#8226 Accommodates Armstrongs inverted bucket, disc, thermostatic, thermostatic wafer, bimetallic, and float and thermostatic traps. Any manufacturers 2-bolt steam trap can also be applied to Armstrongs S-2 connector. Standard 360 Stainless Steel Connector &#8226 A compact, lightweight assembly &#8226 Standardization, reducing inventory &#8226 A compact design, simplifying piping &#8226 Accommodates Armstrongs inverted bucket, disc, thermostatic, thermostatic wafer and bimetallic steam traps. Any manufacturers 2-bolt steam trap can also be applied to Armstrongs standard connector.
$218.10 MSRP $ 172.40
Qty:
add to cart
Part #:501-B4924-2
B Series Cast Carbon Steel Y-Type Pipe Strainer Y-Type Cast Carbon Steel (WCB) Strainer &#8226 600lb and 900lb Screwed or Socketweld 1/2in - 3in &#8226 Class 150, 300 Flanged 1/2in - 6in &#8226 Class 600 Flanged 1/2in - 4inScreen chambers won't leak or crush Both ends of the chambers are precisely machined. This means perfectly round and smooth seating surfaces, as well as a fixed chamber length. Since the screen seats snugly on the machined surface, no particle bigger than the screen opening can escape around the end of the screen. Screwed retainers easy in, easy out Straight threads mean it takes less torque to achieve a tight seal with proper gasket compression. Less torque is also required to remove the retainer. For you, that means less danger of "freezing in" than with hard-to-break tapered pipe threads. Off-center blowdown connections for better dirt removal Off-center drains on 2-1/2" and 3" strainers allow you to remove liquid and dirt nearly completely when blowing down the strainer. Also, less liquid will spill when the screen retainer is removed. Many screen choices Many screen materials, meshes and perforations are available.
$343.00 MSRP $ 288.93
Qty:
add to cart
Part #:501-B5663
CD-33 Series Disc Steam TrapFor steam service up to 600 psig (42 barg) Capacities to 2,500 lb/hr (1,134 kg/hr). The Armstrong CD-33 is a disc-style trap designed to control the traps cycle rate. By reducing the cycle rate, the Armstrong CD-33 extends its service life well beyond that of typical disc traps. This enhanced performance minimizes maintenance time and greatly reduces steam costs. The CD-33 is designed with three discharge ports, which offer stable disc operation to extend operating life. The capacities of the Armstrong CD-33 have been engineered specifically for the following applications large steam main drips, process equipment and HVAC heating equipment on constant pressure. The CD-33L (low capacity) trap is designed for the low capacity applications of steam main drips and steam tracing lines. By ensuring that the capacities are designed to suit the applicationand are not oversizedthe CD-33 Series will last longer than other disc traps with excessive capacity ratings. Heres why &#8226 Three-discharge port design &#8226 Minimum wear with controlled cycling &#8226 Freeze resistant &#8226 Hardened seat and disc
$495.00 MSRP $ 409.95
Qty:
add to cart
Part #:501-B5667
CD-33 Series Disc Steam TrapFor steam service up to 600 psig (42 barg) Capacities to 2,500 lb/hr (1,134 kg/hr). The Armstrong CD-33 is a disc-style trap designed to control the traps cycle rate. By reducing the cycle rate, the Armstrong CD-33 extends its service life well beyond that of typical disc traps. This enhanced performance minimizes maintenance time and greatly reduces steam costs. The CD-33 is designed with three discharge ports, which offer stable disc operation to extend operating life. The capacities of the Armstrong CD-33 have been engineered specifically for the following applications large steam main drips, process equipment and HVAC heating equipment on constant pressure. The CD-33L (low capacity) trap is designed for the low capacity applications of steam main drips and steam tracing lines. By ensuring that the capacities are designed to suit the applicationand are not oversizedthe CD-33 Series will last longer than other disc traps with excessive capacity ratings. Heres why &#8226 Three-discharge port design &#8226 Minimum wear with controlled cycling &#8226 Freeze resistant &#8226 Hardened seat and disc
$390.00 MSRP $ 331.23
Qty:
add to cart
Part #:501-C3510-12
1-AV Series Air and Gas VentsFor pressures to 300 psig (21 bar) or specific gravity down to 0.40. 1-AVA cast iron air vent that uses a free-floating lever that closes positively, ensuring a leaktight closing under all conditions. This vent is good for low capacity air/gas venting up to 300 psi (21 bar).
$275.00 MSRP $ 234.54
Qty:
add to cart
Part #:501-C3510-2
1-AV Series Air and Gas VentsFor pressures to 300 psig (21 bar) or specific gravity down to 0.40. 1-AVA cast iron air vent that uses a free-floating lever that closes positively, ensuring a leaktight closing under all conditions. This vent is good for low capacity air/gas venting up to 300 psi (21 bar).
$275.00 MSRP $ 226.98
Qty:
add to cart
Part #:501-C4448-1
Thermostatic Wafer Steam TrapsArmstrong offers several thermostatic wafer steam traps. The WT-1 is ideal for low-capacity steam tracers and features an exclusive non-welded wafer design, a sealed stainless steel body and an internal strainer screen two to three times larger than that of other thermostatic traps. Choose from NPT or BSPT screwed connections. The WT-2000 is adaptable to a 360 connector to expand piping options and simplify installation. Choose NPT or BSPT screwed or socketweld connections. The WT-2000 is also available for use on the IS-2 stainless steel connector with integral strainer. It can also be used with the TVS 4000. Armstrongs WT-3 is a carbon steel thermostatic wafer trap for superheated drip service. It features an exclusive non-welded wafer design, which eliminates problems associated with weld stress. The WT-3 has no thin-walled enclosures such as bellows or welded diaphragms. It is also resistant to water hammer. Choose NPT or BSPT screwed or socketweld connections. The Series MT from Armstrong is sized precisely to accommodate the extremely low condensate loads found in most instrument steam tracer lines. NOTE Since the normal operation of all suppressed temperature-discharge (subcooling) steam traps is to back up condensate, they should not be used on drip legs for saturated steam service, heating or process equipment. Exercise care in the maintenance of any thermostatic wafer trap with a small discharge area susceptible to clogging.
$1,104.00 MSRP $ 848.53
Qty:
add to cart
Part #:501-C4860
Inverted Bucket Steam TrapsEnergy efficient because it's so reliable The inverted bucket is the most reliable steam trap operating principle known. The heart of its simple design is a unique leverage system that multiplies the force provided by the bucket to open the valve against pressure. Since the bucket is open at the bottom, it resists damage from water hammer, and wear points are heavily reinforced for long life. The inverted bucket has only two moving parts-the valve lever assembly and the bucket. That means no fixed points, no complicated linkage. Nothing to stick, bind or clog. Conserves energy even in the presence of wear Armstrong inverted bucket steam traps open and close based on the difference in density between condensate and steam-the inverted bucket principle. They open and close gently, minimizing wear. This simple fact means that inverted buckets are subject to less wear than some other types of traps. In fact, as an Armstrong inverted bucket trap wears, its tight seal actually improves. The valve and seat of the Armstrong trap provide essentially line contact-resulting in a tight seal because the entire closing force is concentrated on one narrow seating ring. An Armstrong inverted bucket steam trap continues to operate efficiently with use. Gradual wear slightly increases the diameter of the seat and alters the shape and diameter of the valve. But, as this occurs, a tight seal is still preserved-the ball merely seats itself more deeply. Corrosion-resistant parts The stainless steel valve and seat of the Armstrong inverted bucket steam trap are individually ground and lapped together in matched sets. All other working parts are wear- and corrosion-resistant stainless steel. Venting of air and CO2 The Armstrong inverted bucket provides continuous automatic air and CO2 venting with no cooling lag or threat of air binding. Operation against back pressure The Armstrong inverted bucket has excellent performance against back pressure. It has no adverse effect on inverted bucket operation other than to reduce its capacity by the low differential. The bucket simply requires less force to pull the valve open and cycle the trap. Freedom from dirt problems Armstrong designed its inverted bucket to be virtually free of dirt problems. The valve and seat are at the top of the trap, far away from the larger particles of dirt, which fall to the bottom. Here, the up-and-down action of the bucket pulverizes them. Since the valve of an inverted bucket is either fully closed or open, dirt particles pass freely. And the swift flow of condensate from under the bucket's edge creates a unique self-scrubbing action that sweeps dirt out of the trap.
$3,477.00 MSRP $ 3,088.14
Qty:
add to cart
Part #:501-C4920
Steam Trap ConnectorsBesides 2000 Series stainless steel inverted bucket traps, the standard 360 connector or IS-2 connector with integral strainer can also be used on many Armstrong thermostatic, disc, bimetallic, and float and thermostatic traps. Any manufacturers two-bolt steam traps can use Armstrong connectors. IS-2 Stainless Steel Connector with Integral Strainer &#8226 A full line stainless steel strainer in the connector eliminates leak points and reduces installation time &#8226 A strainer that is not discarded when the trap is replaced &#8226 Easy strainer screen replacement &#8226 Optional blowdown valve &#8226 Accommodates Armstrongs inverted bucket, disc, thermostatic, thermostatic wafer, bimetallic, and float and thermostatic traps. Any manufacturers 2-bolt steam trap can also be applied to Armstrongs S-2 connector. Standard 360 Stainless Steel Connector &#8226 A compact, lightweight assembly &#8226 Standardization, reducing inventory &#8226 A compact design, simplifying piping &#8226 Accommodates Armstrongs inverted bucket, disc, thermostatic, thermostatic wafer and bimetallic steam traps. Any manufacturers 2-bolt steam trap can also be applied to Armstrongs standard connector.
$361.00 MSRP $ 308.17
Qty:
add to cart
Part #:501-C5297-25
Inverted Bucket Steam TrapsEnergy efficient because it's so reliable The inverted bucket is the most reliable steam trap operating principle known. The heart of its simple design is a unique leverage system that multiplies the force provided by the bucket to open the valve against pressure. Since the bucket is open at the bottom, it resists damage from water hammer, and wear points are heavily reinforced for long life. The inverted bucket has only two moving parts-the valve lever assembly and the bucket. That means no fixed points, no complicated linkage. Nothing to stick, bind or clog. Conserves energy even in the presence of wear Armstrong inverted bucket steam traps open and close based on the difference in density between condensate and steam-the inverted bucket principle. They open and close gently, minimizing wear. This simple fact means that inverted buckets are subject to less wear than some other types of traps. In fact, as an Armstrong inverted bucket trap wears, its tight seal actually improves. The valve and seat of the Armstrong trap provide essentially line contact-resulting in a tight seal because the entire closing force is concentrated on one narrow seating ring. An Armstrong inverted bucket steam trap continues to operate efficiently with use. Gradual wear slightly increases the diameter of the seat and alters the shape and diameter of the valve. But, as this occurs, a tight seal is still preserved-the ball merely seats itself more deeply. Corrosion-resistant parts The stainless steel valve and seat of the Armstrong inverted bucket steam trap are individually ground and lapped together in matched sets. All other working parts are wear- and corrosion-resistant stainless steel. Venting of air and CO2 The Armstrong inverted bucket provides continuous automatic air and CO2 venting with no cooling lag or threat of air binding. Operation against back pressure The Armstrong inverted bucket has excellent performance against back pressure. It has no adverse effect on inverted bucket operation other than to reduce its capacity by the low differential. The bucket simply requires less force to pull the valve open and cycle the trap. Freedom from dirt problems Armstrong designed its inverted bucket to be virtually free of dirt problems. The valve and seat are at the top of the trap, far away from the larger particles of dirt, which fall to the bottom. Here, the up-and-down action of the bucket pulverizes them. Since the valve of an inverted bucket is either fully closed or open, dirt particles pass freely. And the swift flow of condensate from under the bucket's edge creates a unique self-scrubbing action that sweeps dirt out of the trap.
$307.00 MSRP $ 260.73
Qty:
add to cart
Part #:501-C5297-26
Inverted Bucket Steam TrapsEnergy efficient because it's so reliable The inverted bucket is the most reliable steam trap operating principle known. The heart of its simple design is a unique leverage system that multiplies the force provided by the bucket to open the valve against pressure. Since the bucket is open at the bottom, it resists damage from water hammer, and wear points are heavily reinforced for long life. The inverted bucket has only two moving parts-the valve lever assembly and the bucket. That means no fixed points, no complicated linkage. Nothing to stick, bind or clog. Conserves energy even in the presence of wear Armstrong inverted bucket steam traps open and close based on the difference in density between condensate and steam-the inverted bucket principle. They open and close gently, minimizing wear. This simple fact means that inverted buckets are subject to less wear than some other types of traps. In fact, as an Armstrong inverted bucket trap wears, its tight seal actually improves. The valve and seat of the Armstrong trap provide essentially line contact-resulting in a tight seal because the entire closing force is concentrated on one narrow seating ring. An Armstrong inverted bucket steam trap continues to operate efficiently with use. Gradual wear slightly increases the diameter of the seat and alters the shape and diameter of the valve. But, as this occurs, a tight seal is still preserved-the ball merely seats itself more deeply. Corrosion-resistant parts The stainless steel valve and seat of the Armstrong inverted bucket steam trap are individually ground and lapped together in matched sets. All other working parts are wear- and corrosion-resistant stainless steel. Venting of air and CO2 The Armstrong inverted bucket provides continuous automatic air and CO2 venting with no cooling lag or threat of air binding. Operation against back pressure The Armstrong inverted bucket has excellent performance against back pressure. It has no adverse effect on inverted bucket operation other than to reduce its capacity by the low differential. The bucket simply requires less force to pull the valve open and cycle the trap. Freedom from dirt problems Armstrong designed its inverted bucket to be virtually free of dirt problems. The valve and seat are at the top of the trap, far away from the larger particles of dirt, which fall to the bottom. Here, the up-and-down action of the bucket pulverizes them. Since the valve of an inverted bucket is either fully closed or open, dirt particles pass freely. And the swift flow of condensate from under the bucket's edge creates a unique self-scrubbing action that sweeps dirt out of the trap.
$307.00 MSRP $ 260.73
Qty:
add to cart
Part #:501-C5297-27
Inverted Bucket Steam TrapsEnergy efficient because it's so reliable The inverted bucket is the most reliable steam trap operating principle known. The heart of its simple design is a unique leverage system that multiplies the force provided by the bucket to open the valve against pressure. Since the bucket is open at the bottom, it resists damage from water hammer, and wear points are heavily reinforced for long life. The inverted bucket has only two moving parts-the valve lever assembly and the bucket. That means no fixed points, no complicated linkage. Nothing to stick, bind or clog. Conserves energy even in the presence of wear Armstrong inverted bucket steam traps open and close based on the difference in density between condensate and steam-the inverted bucket principle. They open and close gently, minimizing wear. This simple fact means that inverted buckets are subject to less wear than some other types of traps. In fact, as an Armstrong inverted bucket trap wears, its tight seal actually improves. The valve and seat of the Armstrong trap provide essentially line contact-resulting in a tight seal because the entire closing force is concentrated on one narrow seating ring. An Armstrong inverted bucket steam trap continues to operate efficiently with use. Gradual wear slightly increases the diameter of the seat and alters the shape and diameter of the valve. But, as this occurs, a tight seal is still preserved-the ball merely seats itself more deeply. Corrosion-resistant parts The stainless steel valve and seat of the Armstrong inverted bucket steam trap are individually ground and lapped together in matched sets. All other working parts are wear- and corrosion-resistant stainless steel. Venting of air and CO2 The Armstrong inverted bucket provides continuous automatic air and CO2 venting with no cooling lag or threat of air binding. Operation against back pressure The Armstrong inverted bucket has excellent performance against back pressure. It has no adverse effect on inverted bucket operation other than to reduce its capacity by the low differential. The bucket simply requires less force to pull the valve open and cycle the trap. Freedom from dirt problems Armstrong designed its inverted bucket to be virtually free of dirt problems. The valve and seat are at the top of the trap, far away from the larger particles of dirt, which fall to the bottom. Here, the up-and-down action of the bucket pulverizes them. Since the valve of an inverted bucket is either fully closed or open, dirt particles pass freely. And the swift flow of condensate from under the bucket's edge creates a unique self-scrubbing action that sweeps dirt out of the trap.
$307.00 MSRP $ 260.73
Qty:
add to cart
Part #:501-C5297-29
Inverted Bucket Steam TrapsEnergy efficient because it's so reliable The inverted bucket is the most reliable steam trap operating principle known. The heart of its simple design is a unique leverage system that multiplies the force provided by the bucket to open the valve against pressure. Since the bucket is open at the bottom, it resists damage from water hammer, and wear points are heavily reinforced for long life. The inverted bucket has only two moving parts-the valve lever assembly and the bucket. That means no fixed points, no complicated linkage. Nothing to stick, bind or clog. Conserves energy even in the presence of wear Armstrong inverted bucket steam traps open and close based on the difference in density between condensate and steam-the inverted bucket principle. They open and close gently, minimizing wear. This simple fact means that inverted buckets are subject to less wear than some other types of traps. In fact, as an Armstrong inverted bucket trap wears, its tight seal actually improves. The valve and seat of the Armstrong trap provide essentially line contact-resulting in a tight seal because the entire closing force is concentrated on one narrow seating ring. An Armstrong inverted bucket steam trap continues to operate efficiently with use. Gradual wear slightly increases the diameter of the seat and alters the shape and diameter of the valve. But, as this occurs, a tight seal is still preserved-the ball merely seats itself more deeply. Corrosion-resistant parts The stainless steel valve and seat of the Armstrong inverted bucket steam trap are individually ground and lapped together in matched sets. All other working parts are wear- and corrosion-resistant stainless steel. Venting of air and CO2 The Armstrong inverted bucket provides continuous automatic air and CO2 venting with no cooling lag or threat of air binding. Operation against back pressure The Armstrong inverted bucket has excellent performance against back pressure. It has no adverse effect on inverted bucket operation other than to reduce its capacity by the low differential. The bucket simply requires less force to pull the valve open and cycle the trap. Freedom from dirt problems Armstrong designed its inverted bucket to be virtually free of dirt problems. The valve and seat are at the top of the trap, far away from the larger particles of dirt, which fall to the bottom. Here, the up-and-down action of the bucket pulverizes them. Since the valve of an inverted bucket is either fully closed or open, dirt particles pass freely. And the swift flow of condensate from under the bucket's edge creates a unique self-scrubbing action that sweeps dirt out of the trap.
$307.00 MSRP $ 260.73
Qty:
add to cart
 
Displaying: 1 - 24 of 506 Matching Items