Appleton
Armstrong International


Displaying: 1 - 23 of 23 Matching Items
23 Items
View:
Active Filters :
Part #:304003
Appleton and O-Z/Gedney K-clamps are designed to secure rigid metal conduit IMC or EMT. They can be used across parallel or perpendicular to beam channel and angle supports.
$ 21.72
Qty:
add to cart
Part #:300864
Appleton and O-Z/Gedney K-clamps are designed to secure rigid metal conduit IMC or EMT. They can be used across parallel or perpendicular to beam channel and angle supports
$ 8.48
Qty:
add to cart
Part #:301655
Appleton and O-Z/Gedney metallic 4 octagon boxes extension rings and covers are widely recognized for quality selection and ease of installation. They may be used as a junction box or a device box for switches receptacles GFCIs etc. Manufactured of durable materials with consistent construction means easy installation making all the difference in the speed and final quality of any wiring job.
$ 26.89
Qty:
add to cart
Part #:302553
Appleton and O-Z/Gedney offer ETP 4000S Series steel EMT set screw connectors. They are used to ground and secure EMT raceways to boxes and enclosures. The 4000S Series have a male NPS threaded hub and are available with or without an insulated throat.
$ 30.55
Qty:
add to cart
Part #:302840
Appleton HUB threaded conduit hubs are general purpose fittings designed for RMC and IMC. They provide a more vibration resistant connection with assured ground continuity. The HUB design is an insulated throat form with a bonding screw. The o-ring provides a watertight connection between the hub and an enclosure.
$ 157.47
Qty:
add to cart
Part #:304014
Appleton and O-Z/Gedney offer ETP 5000S Series steel EMT set screw couplings. They are used to ground and secure EMT raceway sections together.
$ 21.09
Qty:
add to cart
Part #:306957
Appleton and O-Z/Gedney rigid conduit and IMC locknuts are used to secure and ground conduits and fittings to enclosures and prevents loosening due to vibration or motion. They are available in plain gasketed and bonding styles.
$ 24.81
Qty:
add to cart
Part #:307130
O-Z/Gedney threaded three piece couplings join two lengths of conduit when neither can be turned. Elbows provide a 90 change of direction in a conduit run. Gasket elbows also provide a compact wire pulling point.
$ 417.49
Qty:
add to cart
Part #:307360
Appleton offers beam clamps straps clamps and clamp backs for rigid metal conduit or imc. Beam clamps provide support for conduit hanging systems. Two-hole straps are used to support rigid metal conduit and IMC. Clamp backs provide spacing from mounting surfaces when they are used with pipe clamps.
$ 16.32
Qty:
add to cart
Part #:308324
Appleton Form 35 Malleable Iron Conduit Outlet Bodies Covers and Gaskets are used to connect and change direction of conduit runs. In addition to making bends in a conduit system they allow connections for branch runs. These conduit bodies serve as pulling fittings and permit access to conductors for splicing and maintenance.
$ 477.81
Qty:
add to cart
Part #:308421
Appleton Form 85 Unilets Conduit Outlet Bodies Covers and Gaskets are used to connect and change direction of conduit runs. In addition to making bends in a conduit system they allow connections for branch runs. These conduit bodies serve as pulling fittings and permit access to conductors for splicing and maintenance.
$ 34.13
Qty:
add to cart
$20.59 MSRP $ 11.75
Qty:
add to cart
$12.95 MSRP $ 7.39
Qty:
add to cart
$9.87 MSRP $ 5.63
Qty:
add to cart
$12.36 MSRP $ 7.05
Qty:
add to cart
$11.97 MSRP $ 6.82
Qty:
add to cart
Part #:501-D25979
DS Series In-Line Condensate SeparatorsDuctile Iron Drain SeparatorCondensate in steam and air piping reduces thermal efficiency, causes water hammer, corrodes equipment such as valves and pipes, and causes other problems. In-line (drain) separators DS-1, DS-2, DS-3, and DS-4 separate condensate efficiently by using the centrifugal force of steam or air created by introducing it into a specifically shaped path. Because of the simple structure of the drain separators, pressure loss is minimized, enabling clean, dry steam or air to be fed to equipment. When steam or air flow enters the drain separator, centrifugal force is generated in the fluid because of the devices internal structural design. The fluid drains along the wall because of the difference in specific gravity with steam or air, eventually striking the baffle. The baffle guides the fluid to the drain outlet and to the trap, which drains it. As a result, small dirt particles and condensate are separated and removed from the system through the bottom drain. &#8226 Cyclone structure maximizes liquid separation efficiency &#8226 Pressure loss is extremely low &#8226 No moving parts means no breakdowns
$3,821.00 MSRP $ 2,936.82
Qty:
add to cart
Part #:501-D25980
DS Series In-Line Condensate SeparatorsDuctile Iron Drain SeparatorCondensate in steam and air piping reduces thermal efficiency, causes water hammer, corrodes equipment such as valves and pipes, and causes other problems. In-line (drain) separators DS-1, DS-2, DS-3, and DS-4 separate condensate efficiently by using the centrifugal force of steam or air created by introducing it into a specifically shaped path. Because of the simple structure of the drain separators, pressure loss is minimized, enabling clean, dry steam or air to be fed to equipment. When steam or air flow enters the drain separator, centrifugal force is generated in the fluid because of the devices internal structural design. The fluid drains along the wall because of the difference in specific gravity with steam or air, eventually striking the baffle. The baffle guides the fluid to the drain outlet and to the trap, which drains it. As a result, small dirt particles and condensate are separated and removed from the system through the bottom drain. &#8226 Cyclone structure maximizes liquid separation efficiency &#8226 Pressure loss is extremely low &#8226 No moving parts means no breakdowns
$3,924.00 MSRP $ 3,015.99
Qty:
add to cart
Part #:501-D27089
AEH Series Exhaust Heads Armstrongs AEH series carbon steel exhaust heads should be used when there is a risk of water carryover up an atmospheric vent pipe. The internal knock-out plate and stainless steel mesh screening effectively contains water carry-over and discharges it through the bottom drain leaving dry flash steam to vent through the top of the vessel. Connections &#8226 Flanged ASME B16.5 CL 150 &#8226 Drain FNPT
$3,100.20 MSRP $ 2,360.10
Qty:
add to cart
Part #:501-D29066
DS Series In-Line Condensate SeparatorsCarbon Steel Drain SeparatorCondensate in steam and air piping reduces thermal efficiency, causes water hammer, corrodes equipment such as valves and pipes, and causes other problems. In-line (drain) separators DS-1, DS-2, DS-3, and DS-4 separate condensate efficiently by using the centrifugal force of steam or air created by introducing it into a specifically shaped path. Because of the simple structure of the drain separators, pressure loss is minimized, enabling clean, dry steam or air to be fed to equipment. When steam or air flow enters the drain separator, centrifugal force is generated in the fluid because of the devices internal structural design. The fluid drains along the wall because of the difference in specific gravity with steam or air, eventually striking the baffle. The baffle guides the fluid to the drain outlet and to the trap, which drains it. As a result, small dirt particles and condensate are separated and removed from the system through the bottom drain. &#8226 Cyclone structure maximizes liquid separation efficiency &#8226 Pressure loss is extremely low &#8226 No moving parts means no breakdowns
$9,811.00 MSRP $ 7,419.55
Qty:
add to cart
Part #:501-D33865
DS Series In-Line Condensate SeparatorsCarbon Steel Drain SeparatorCondensate in steam and air piping reduces thermal efficiency, causes water hammer, corrodes equipment such as valves and pipes, and causes other problems. In-line (drain) separators DS-1, DS-2, DS-3, and DS-4 separate condensate efficiently by using the centrifugal force of steam or air created by introducing it into a specifically shaped path. Because of the simple structure of the drain separators, pressure loss is minimized, enabling clean, dry steam or air to be fed to equipment. When steam or air flow enters the drain separator, centrifugal force is generated in the fluid because of the devices internal structural design. The fluid drains along the wall because of the difference in specific gravity with steam or air, eventually striking the baffle. The baffle guides the fluid to the drain outlet and to the trap, which drains it. As a result, small dirt particles and condensate are separated and removed from the system through the bottom drain. &#8226 Cyclone structure maximizes liquid separation efficiency &#8226 Pressure loss is extremely low &#8226 No moving parts means no breakdowns
$8,974.00 MSRP $ 7,421.38
Qty:
add to cart
Part #:501-D503469
A/CA Series Cast Iron Y-Type Pipe Strainer Y-Type Cast Iron Strainer &#8226 250lb Screwed 1/2in - 3in &#8226 Class 125 Flanged 2in - 6in &#8226 Class 250 Flanged 2in - 6inScreen chambers won't leak or crush Both ends of the chambers are precisely machined. This means perfectly round and smooth seating surfaces, as well as a fixed chamber length. Since the screen seats snugly on the machined surface, no particle bigger than the screen opening can escape around the end of the screen. Screwed retainers easy in, easy out Straight threads mean it takes less torque to achieve a tight seal with proper gasket compression. Less torque is also required to remove the retainer. For you, that means less danger of "freezing in" than with hard-to-break tapered pipe threads. Off-center blowdown connections for better dirt removal Off-center drains on 2-1/2" and 3" strainers allow you to remove liquid and dirt nearly completely when blowing down the strainer. Also, less liquid will spill when the screen retainer is removed. Many screen choices Many screen materials, meshes and perforations are available.
$1,985.00 MSRP $ 1,622.25
Qty:
add to cart
Part #:501-FH1367
Pumping TrapsArmstrong pump traps offer the following features, advantages and benefits Non-electric Utilizes inexpensive steam, air or gas for operation and has no seals, motors, impellers or electric components, which frequently fail. Wear and corrosion resistance. Mechanism frame assembly is constructed of rugged investment-cast stainless steel components. Stress chloride corrosion resistance Inconel X-750 springs have higher resistance to the stress that causes lower-grade stainless steel springs to fail. Corrosion resistance Entire float mechanism is stainless steel. Float is Heliarc welded to avoid the introduction of dissimilar metals, which could lead to galvanic corrosion and float failure. Externally replaceable valve and seat assembly Maintenance is a "snap" with hardened stainless steel valves that can be cleaned or replaced without cap removal. Explosion proof Intrinsically safe due to all-stainless steel construction of mechanism. Long life and dependable service. Simple float/spring operation and rugged all-stainless steel construction allow for long, trouble-free service life. Compact, low-profile design Low-profile design allows for maximum pump capacity with minimal fill head and floor space requirements. PT-300 Series horizontal tank design provides the highest capacity with the lowest profile on the market.
$38,511.10 MSRP $ 29,317.70
Qty:
add to cart
 
Displaying: 1 - 23 of 23 Matching Items