Shop by Category
New

Square D BDA36040 40a 600v Breaker 01122

Part # : 303822
 
$ 631.60

Product Description

PowerPact B-Frame Molded Case Circuit Breakers - BDA36040

PowerPact - circuit breaker - 40A 3P AC 18kA at 600Y/347V (UL) - I-Line


Product Specifications

  • Main Category: Electrical Equipment
  • Brand: Square D
  • Weight (lbs): 3.82
  • Fuses, Circuit Breakers, Load Centers, and Safety Switches: Circuit Breakers
  • AC/DC: AC
  • Number of Poles: 3
  • Voltage: 600V
  • Amperage: 40A
  • Number of Phases: 3
  • Part Number: 01122

Applications/Usage & Features

Main
range
PowerPact
 
product name
PowerPact B
 
device short name
BD 040
 
product or component type
Circuit breaker
 
device application
Distribution
 

 

Complementary
Line Rated Current
40 A
 
Number of Poles
3P
 
protected poles description
3t
 
control type
Toggle
 
breaking capacity code
D
 
breaking capacity
25 kA at 240 V AC 50/60 Hz according to UL 489
14 kA at 600 V AC 50/60 Hz according to UL 489
18 kA at 600Y/347 V AC 50/60 Hz according to UL 489
20 kA at 250 V DC 50/60 Hz according to UL 489
Icu : 25 kA at 480/277 V AC 50/60 Hz according to IEC 60947-2
25 kA at 480 V AC 50/60 Hz according to UL 489
18 kA at 125 V DC 50/60 Hz according to UL 489
18 kA at 250 V DC 50/60 Hz according to UL 489
 
System Voltage
240 V AC 50/60 Hz according to IEC 60947-2
347 V AC 50/60 Hz according to UL 489
125 V DC 50/60 Hz according to UL 489
250 V DC 50/60 Hz according to UL 489
 
[Ics] rated service breaking capacity
25 kA: at 220...240 V AC 50/60 Hz according to IEC 60947-2
18 kA: at 380...415 V AC 50/60 Hz according to IEC 60947-2
18 kA: at 440 V AC 50/60 Hz according to IEC 60947-2
14 kA: at 500...525 V AC 50/60 Hz according to IEC 60947-2
 
[Uimp] rated impulse withstand voltage
8 kV according to IEC 60947-2
 
[Ui] rated insulation voltage
800 V according to IEC 60947-2
 
trip unit technology
Thermal-magnetic
 
trip unit name
TM-D
 
suitability for isolation
Yes according to IEC 60947-2
 
utilisation category
Category A
 
Mechanical durability
20000 cycles according to IEC 947-1 Annex K ed 5.2
 
Electrical durability
10000 cycles according to IEC 947-1 Annex K ed 5.2 In at 440 V
 
connection pitch
1.06 in (27 mm)
 
local signalling
Green flag presence of auxiliary contacts
 
mounting mode
I-Line
 
electrical connection
I-Line connection at line
Lugs at load
 
AWG gauge
AWG 14...AWG 2/0 (aluminium/copper)
 
mounting height
4.49 in (114 mm)
 
tightening torque
3.6...4.4 N.m 0...0.01 in² (2.5...6 mm²) (AWG 14...AWG 10)
5...6.2 N.m 0.02...0.11 in² (10...70 mm²) (AWG 8...AWG 2/0)
 
number of slots
1 auxiliary switch OF (plug-in)
1 voltage release MN or MX (plug-in)
1 alarm switch SD (plug-in)
 
Power wire stripping length
0.79 in (20 mm)
 
Color
Grey (RAL 7016)
 
9 mm pitches
9
 
height
5.39 in (137 mm)
 
width
3.19 in (81 mm)
 
depth
3.5 in (89 mm)
 
product weight
2.9 lb(US) (1.315 kg)
 
quantity per set
Set of 1
 
phase connection
ABC
 
continuous current rating
80 %
 

 

Environment
quality labels
CE
 
standards
EN/IEC 60947-2
EN/IEC 60947-5-1
GB 14048.2
NEMA AB1
UL 489
CSA C22.2 No 5
NMX J-266
 
product certifications
UL
CSA
CCC
EAC
NOM
IEC
 
IP degree of protection
IP40 (front cover) according to IEC 60529
 
IK degree of protection
IK07 according to IEC 62262
 
pollution degree
3 according to IEC 60947-1
 
ambient air temperature for operation
-13...158 °F (-25...70 °C)
 
ambient air temperature for storage
-58...185 °F (-50...85 °C)
 
operating altitude
With derating
Without derating
 

 

Ordering and shipping details
Category
01133 - BDA I-LINE BREAKER
 
Discount Schedule
DE2
 
GTIN
003606481152596
 
Nbr. of units in pkg.
1
 
Package weight(Lbs)
3.8200000000000003
 
Returnability
Y
 
Country of origin
MX